Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads Formula

Fx Copy
LaTeX Copy
Live Load are variable as they depend on usage and capacity. Check FAQs
LL=U-(1.4DL)1.7
LL - Live Load?U - Ultimate Strength?DL - Dead Load?

Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads Example

With values
With units
Only example

Here is how the Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads equation looks like with Values.

Here is how the Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads equation looks like with Units.

Here is how the Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads equation looks like.

3.5212Edit=20Edit-(1.410.01Edit)1.7
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Structural Engineering » fx Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads

Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads Solution

Follow our step by step solution on how to calculate Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads?

FIRST Step Consider the formula
LL=U-(1.4DL)1.7
Next Step Substitute values of Variables
LL=20kN/m²-(1.410.01kN/m²)1.7
Next Step Convert Units
LL=20000Pa-(1.410010Pa)1.7
Next Step Prepare to Evaluate
LL=20000-(1.410010)1.7
Next Step Evaluate
LL=3521.17647058824Pa
Next Step Convert to Output's Unit
LL=3.52117647058824kN/m²
LAST Step Rounding Answer
LL=3.5212kN/m²

Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads Formula Elements

Variables
Live Load
Live Load are variable as they depend on usage and capacity.
Symbol: LL
Measurement: PressureUnit: kN/m²
Note: Value should be greater than 0.
Ultimate Strength
ultimate strengths is the capacities to resist design loads and their related internal moments and forces.
Symbol: U
Measurement: PressureUnit: kN/m²
Note: Value should be greater than 0.
Dead Load
Dead Load consisting of basic load plus volume change due to (shrinkage,temperature).
Symbol: DL
Measurement: PressureUnit: kN/m²
Note: Value should be greater than 0.

Other formulas in Partial Safety Factors for Loads category

​Go Basic Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads
DL=U-(1.7LL)1.4
​Go Ultimate Strength when Wind and Earthquake Loads are not Applied
U=(1.4DL)+(1.7LL)
​Go Ultimate Strength when Wind Loads are Applied
U=(0.9DL)+(1.3W)
​Go Basic Load Effect given Ultimate Strength for Applied Wind Loads
DL=U-(1.3W)0.9

How to Evaluate Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads?

Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads evaluator uses Live Load = (Ultimate Strength-(1.4*Dead Load))/(1.7) to evaluate the Live Load, The Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads formula is defined as those loads produced by the use and occupancy of a building or structure and do not include construction loads, environmental loads (such as wind loads, snow loads, rain loads, earthquake loads and flood loads) or dead loads. Live Load is denoted by LL symbol.

How to evaluate Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads using this online evaluator? To use this online evaluator for Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads, enter Ultimate Strength (U) & Dead Load (DL) and hit the calculate button.

FAQs on Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads

What is the formula to find Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads?
The formula of Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads is expressed as Live Load = (Ultimate Strength-(1.4*Dead Load))/(1.7). Here is an example- 0.003529 = (20000-(1.4*10010))/(1.7).
How to calculate Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads?
With Ultimate Strength (U) & Dead Load (DL) we can find Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads using the formula - Live Load = (Ultimate Strength-(1.4*Dead Load))/(1.7).
Can the Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads be negative?
No, the Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads, measured in Pressure cannot be negative.
Which unit is used to measure Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads?
Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads is usually measured using the Kilonewton per Square Meter[kN/m²] for Pressure. Pascal[kN/m²], Kilopascal[kN/m²], Bar[kN/m²] are the few other units in which Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads can be measured.
Copied!