Liquid Vapor Flow Factor in Distillation Column Design Formula

Fx Copy
LaTeX Copy
Flow Factor is used to characterize the vapor and liquid flow rates on a tray or between trays. Check FAQs
FLV=(LwVW)((ρVρL)0.5)
FLV - Flow Factor?Lw - Liquid Mass Flowrate?VW - Vapor Mass Flowrate?ρV - Vapor Density in Distillation?ρL - Liquid Density?

Liquid Vapor Flow Factor in Distillation Column Design Example

With values
With units
Only example

Here is how the Liquid Vapor Flow Factor in Distillation Column Design equation looks like with Values.

Here is how the Liquid Vapor Flow Factor in Distillation Column Design equation looks like with Units.

Here is how the Liquid Vapor Flow Factor in Distillation Column Design equation looks like.

0.1282Edit=(12.856Edit4.157Edit)((1.71Edit995Edit)0.5)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Process Equipment Design » fx Liquid Vapor Flow Factor in Distillation Column Design

Liquid Vapor Flow Factor in Distillation Column Design Solution

Follow our step by step solution on how to calculate Liquid Vapor Flow Factor in Distillation Column Design?

FIRST Step Consider the formula
FLV=(LwVW)((ρVρL)0.5)
Next Step Substitute values of Variables
FLV=(12.856kg/s4.157kg/s)((1.71kg/m³995kg/m³)0.5)
Next Step Prepare to Evaluate
FLV=(12.8564.157)((1.71995)0.5)
Next Step Evaluate
FLV=0.128207181880326
LAST Step Rounding Answer
FLV=0.1282

Liquid Vapor Flow Factor in Distillation Column Design Formula Elements

Variables
Flow Factor
Flow Factor is used to characterize the vapor and liquid flow rates on a tray or between trays.
Symbol: FLV
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Liquid Mass Flowrate
Liquid Mass Flowrate is the mass flow rate of the liquid component in the column.
Symbol: Lw
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Vapor Mass Flowrate
Vapor Mass Flowrate is the mass flow rate of vapor component in column.
Symbol: VW
Measurement: Mass Flow RateUnit: kg/s
Note: Value should be greater than 0.
Vapor Density in Distillation
Vapor Density in Distillation is defined as the ratio of mass to the volume of vapor at particular temperature in a distillation Column.
Symbol: ρV
Measurement: DensityUnit: kg/m³
Note: Value should be greater than 0.
Liquid Density
Liquid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies.
Symbol: ρL
Measurement: DensityUnit: kg/m³
Note: Value should be greater than 0.

Other formulas in Distillation Tower Design category

​Go Clearance Area under Downcomer given Weir Length and Apron Height
Aap=haplw
​Go Active Area given Gas Volumetric Flow and Flow Velocity
Aa=Gvfduf
​Go Column Diameter Based on Vapor Flowrate and Mass Velocity of Vapor
Dc=(4VWπWmax)12
​Go Column Diameter given Maximum Vapor Rate and Maximum Vapor Velocity
Dc=4VWπρVUv

How to Evaluate Liquid Vapor Flow Factor in Distillation Column Design?

Liquid Vapor Flow Factor in Distillation Column Design evaluator uses Flow Factor = (Liquid Mass Flowrate/Vapor Mass Flowrate)*((Vapor Density in Distillation/Liquid Density)^0.5) to evaluate the Flow Factor, The Liquid Vapor Flow Factor in Distillation Column Design formula is defined as a dimensionless parameter that provides important information about the relative flow rates of vapor and liquid on a distillation tray. Flow Factor is denoted by FLV symbol.

How to evaluate Liquid Vapor Flow Factor in Distillation Column Design using this online evaluator? To use this online evaluator for Liquid Vapor Flow Factor in Distillation Column Design, enter Liquid Mass Flowrate (Lw), Vapor Mass Flowrate (VW), Vapor Density in Distillation V) & Liquid Density L) and hit the calculate button.

FAQs on Liquid Vapor Flow Factor in Distillation Column Design

What is the formula to find Liquid Vapor Flow Factor in Distillation Column Design?
The formula of Liquid Vapor Flow Factor in Distillation Column Design is expressed as Flow Factor = (Liquid Mass Flowrate/Vapor Mass Flowrate)*((Vapor Density in Distillation/Liquid Density)^0.5). Here is an example- 0.128207 = (12.856/4.157)*((1.71/995)^0.5).
How to calculate Liquid Vapor Flow Factor in Distillation Column Design?
With Liquid Mass Flowrate (Lw), Vapor Mass Flowrate (VW), Vapor Density in Distillation V) & Liquid Density L) we can find Liquid Vapor Flow Factor in Distillation Column Design using the formula - Flow Factor = (Liquid Mass Flowrate/Vapor Mass Flowrate)*((Vapor Density in Distillation/Liquid Density)^0.5).
Copied!