The Line to Neutral Current is a current flow between the line to neutral. Check FAQs
Iln=Q3Vlnsin(Φ)
Iln - Line to Neutral Current?Q - Reactive Power?Vln - Line to Neutral Voltage?Φ - Phase Difference?

Line to Neutral Current using Reactive Power Example

With values
With units
Only example

Here is how the Line to Neutral Current using Reactive Power equation looks like with Values.

Here is how the Line to Neutral Current using Reactive Power equation looks like with Units.

Here is how the Line to Neutral Current using Reactive Power equation looks like.

1.2966Edit=134Edit368.9Editsin(30Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Electrical Circuit » fx Line to Neutral Current using Reactive Power

Line to Neutral Current using Reactive Power Solution

Follow our step by step solution on how to calculate Line to Neutral Current using Reactive Power?

FIRST Step Consider the formula
Iln=Q3Vlnsin(Φ)
Next Step Substitute values of Variables
Iln=134VAR368.9Vsin(30°)
Next Step Convert Units
Iln=134W368.9Vsin(0.5236rad)
Next Step Prepare to Evaluate
Iln=134368.9sin(0.5236)
Next Step Evaluate
Iln=1.29656507014998A
LAST Step Rounding Answer
Iln=1.2966A

Line to Neutral Current using Reactive Power Formula Elements

Variables
Functions
Line to Neutral Current
The Line to Neutral Current is a current flow between the line to neutral.
Symbol: Iln
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Reactive Power
Reactive Power is a measure of the energy exchange between the source and the reactive part of the load.
Symbol: Q
Measurement: PowerUnit: VAR
Note: Value can be positive or negative.
Line to Neutral Voltage
The Line to Neutral Voltage (usually referred to as phase voltage) is the voltage between any of the 3 phases and the central star point which is connected to the earth.
Symbol: Vln
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
sin
Sine is a trigonometric function that describes the ratio of the length of the opposite side of a right triangle to the length of the hypotenuse.
Syntax: sin(Angle)

Other Formulas to find Line to Neutral Current

​Go Line to Neutral Current using Real Power
Iln=P3cos(Φ)Vln

Other formulas in AC Circuit Design category

​Go Capacitance for Parallel RLC Circuit using Q Factor
C=LQ||2R2
​Go Capacitance for Series RLC Circuit given Q Factor
C=LQse2R2
​Go Capacitance given Cut off Frequency
C=12Rπfc
​Go Capacitance using Time Constant
C=τR

How to Evaluate Line to Neutral Current using Reactive Power?

Line to Neutral Current using Reactive Power evaluator uses Line to Neutral Current = Reactive Power/(3*Line to Neutral Voltage*sin(Phase Difference)) to evaluate the Line to Neutral Current, Line to Neutral Current using Reactive Power is a current flow between the line to neutral and reactive power is the power that flows back from a destination toward the grid in an alternating current scenario. Line to Neutral Current is denoted by Iln symbol.

How to evaluate Line to Neutral Current using Reactive Power using this online evaluator? To use this online evaluator for Line to Neutral Current using Reactive Power, enter Reactive Power (Q), Line to Neutral Voltage (Vln) & Phase Difference (Φ) and hit the calculate button.

FAQs on Line to Neutral Current using Reactive Power

What is the formula to find Line to Neutral Current using Reactive Power?
The formula of Line to Neutral Current using Reactive Power is expressed as Line to Neutral Current = Reactive Power/(3*Line to Neutral Voltage*sin(Phase Difference)). Here is an example- 1.296565 = 134/(3*68.9*sin(0.5235987755982)).
How to calculate Line to Neutral Current using Reactive Power?
With Reactive Power (Q), Line to Neutral Voltage (Vln) & Phase Difference (Φ) we can find Line to Neutral Current using Reactive Power using the formula - Line to Neutral Current = Reactive Power/(3*Line to Neutral Voltage*sin(Phase Difference)). This formula also uses Sine (sin) function(s).
What are the other ways to Calculate Line to Neutral Current?
Here are the different ways to Calculate Line to Neutral Current-
  • Line to Neutral Current=Real Power/(3*cos(Phase Difference)*Line to Neutral Voltage)OpenImg
Can the Line to Neutral Current using Reactive Power be negative?
Yes, the Line to Neutral Current using Reactive Power, measured in Electric Current can be negative.
Which unit is used to measure Line to Neutral Current using Reactive Power?
Line to Neutral Current using Reactive Power is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Line to Neutral Current using Reactive Power can be measured.