Line Losses is defined as the total losses occurring in an Underground AC line when in use. Check FAQs
Ploss=I22ρLA
Ploss - Line Losses?I - Current Underground AC?ρ - Resistivity?L - Length of Underground AC Wire?A - Area of Underground AC Wire?

Line Losses using Load Current (2 Phase 4 Wire US) Example

With values
With units
Only example

Here is how the Line Losses using Load Current (2 Phase 4 Wire US) equation looks like with Values.

Here is how the Line Losses using Load Current (2 Phase 4 Wire US) equation looks like with Units.

Here is how the Line Losses using Load Current (2 Phase 4 Wire US) equation looks like.

0.0516Edit=9Edit221.7E-5Edit24Edit1.28Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Line Losses using Load Current (2 Phase 4 Wire US)

Line Losses using Load Current (2 Phase 4 Wire US) Solution

Follow our step by step solution on how to calculate Line Losses using Load Current (2 Phase 4 Wire US)?

FIRST Step Consider the formula
Ploss=I22ρLA
Next Step Substitute values of Variables
Ploss=9A221.7E-5Ω*m24m1.28
Next Step Prepare to Evaluate
Ploss=9221.7E-5241.28
Next Step Evaluate
Ploss=0.0516375W
LAST Step Rounding Answer
Ploss=0.0516W

Line Losses using Load Current (2 Phase 4 Wire US) Formula Elements

Variables
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.

Other Formulas to find Line Losses

​Go Line Losses using Area of X-Section (2 Phase 4 Wire US)
Ploss=4ρLP2A(Vm2)(cos(Φ)2)
​Go Line Losses (2 Phase 4 Wire US)
Ploss=2(I2)R
​Go Line Losses using Volume of Conductor Material (2 Phase 4 Wire US)
Ploss=(IL)24ρV

Other formulas in Wire Parameters category

​Go Length using Line Losses (2 Phase 4 Wire US)
L=PlossA2(I2)ρ
​Go Length using Area of X-Section (2 Phase 4 Wire US)
L=APloss(Vm2)(cos(Φ))24ρ(P2)
​Go Area using Line Losses (2 Phase 4 Wire US)
A=(I2)2ρLPloss
​Go Area using Volume of Conductor Material (2 Phase 4 Wire US)
A=V2L

How to Evaluate Line Losses using Load Current (2 Phase 4 Wire US)?

Line Losses using Load Current (2 Phase 4 Wire US) evaluator uses Line Losses = Current Underground AC^2*2*Resistivity*Length of Underground AC Wire/Area of Underground AC Wire to evaluate the Line Losses, The Line Losses using Load Current (2 phase 4 wire US) formula is defined as the loss of electric energy due to the heating of line wires by the current. Line Losses is denoted by Ploss symbol.

How to evaluate Line Losses using Load Current (2 Phase 4 Wire US) using this online evaluator? To use this online evaluator for Line Losses using Load Current (2 Phase 4 Wire US), enter Current Underground AC (I), Resistivity (ρ), Length of Underground AC Wire (L) & Area of Underground AC Wire (A) and hit the calculate button.

FAQs on Line Losses using Load Current (2 Phase 4 Wire US)

What is the formula to find Line Losses using Load Current (2 Phase 4 Wire US)?
The formula of Line Losses using Load Current (2 Phase 4 Wire US) is expressed as Line Losses = Current Underground AC^2*2*Resistivity*Length of Underground AC Wire/Area of Underground AC Wire. Here is an example- 0.051638 = 9^2*2*1.7E-05*24/1.28.
How to calculate Line Losses using Load Current (2 Phase 4 Wire US)?
With Current Underground AC (I), Resistivity (ρ), Length of Underground AC Wire (L) & Area of Underground AC Wire (A) we can find Line Losses using Load Current (2 Phase 4 Wire US) using the formula - Line Losses = Current Underground AC^2*2*Resistivity*Length of Underground AC Wire/Area of Underground AC Wire.
What are the other ways to Calculate Line Losses?
Here are the different ways to Calculate Line Losses-
  • Line Losses=4*Resistivity*Length of Underground AC Wire*(Power Transmitted^2)/(Area of Underground AC Wire*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2))OpenImg
  • Line Losses=2*(Current Underground AC^2)*Resistance Underground ACOpenImg
  • Line Losses=(Current Underground AC*Length of Underground AC Wire)^2*4*Resistivity/Volume Of ConductorOpenImg
Can the Line Losses using Load Current (2 Phase 4 Wire US) be negative?
Yes, the Line Losses using Load Current (2 Phase 4 Wire US), measured in Power can be negative.
Which unit is used to measure Line Losses using Load Current (2 Phase 4 Wire US)?
Line Losses using Load Current (2 Phase 4 Wire US) is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Line Losses using Load Current (2 Phase 4 Wire US) can be measured.
Copied!