Fx Copy
LaTeX Copy
Line Losses is defined as the total losses occurring in an Overhead AC line when in use. Check FAQs
Ploss=Lρ(P2)2A(Vm2)((cos(Φ))2)
Ploss - Line Losses?L - Length of Overhead AC Wire?ρ - Resistivity?P - Power Transmitted?A - Area of Overhead AC Wire?Vm - Maximum Voltage Overhead AC?Φ - Phase Difference?

Line Losses using Area of X-Section(2-Phase 4-Wire OS) Example

With values
With units
Only example

Here is how the Line Losses using Area of X-Section(2-Phase 4-Wire OS) equation looks like with Values.

Here is how the Line Losses using Area of X-Section(2-Phase 4-Wire OS) equation looks like with Units.

Here is how the Line Losses using Area of X-Section(2-Phase 4-Wire OS) equation looks like.

0.0314Edit=10.63Edit1.7E-5Edit(890Edit2)20.79Edit(62Edit2)((cos(30Edit))2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Line Losses using Area of X-Section(2-Phase 4-Wire OS)

Line Losses using Area of X-Section(2-Phase 4-Wire OS) Solution

Follow our step by step solution on how to calculate Line Losses using Area of X-Section(2-Phase 4-Wire OS)?

FIRST Step Consider the formula
Ploss=Lρ(P2)2A(Vm2)((cos(Φ))2)
Next Step Substitute values of Variables
Ploss=10.63m1.7E-5Ω*m(890W2)20.79(62V2)((cos(30°))2)
Next Step Convert Units
Ploss=10.63m1.7E-5Ω*m(890W2)20.79(62V2)((cos(0.5236rad))2)
Next Step Prepare to Evaluate
Ploss=10.631.7E-5(8902)20.79(622)((cos(0.5236))2)
Next Step Evaluate
Ploss=0.0314239279144W
LAST Step Rounding Answer
Ploss=0.0314W

Line Losses using Area of X-Section(2-Phase 4-Wire OS) Formula Elements

Variables
Functions
Line Losses
Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Area of Overhead AC Wire
Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Maximum Voltage Overhead AC
Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other Formulas to find Line Losses

​Go Line Losses(2-Phase 4-Wire OS)
Ploss=(4)((I)2)R
​Go Line Losses using Load Current (2-Phase 4-Wire OS)
Ploss=4R(I)2

Other formulas in Wire Parameters category

​Go Volume of Conductor Material(2-Phase 4-Wire OS)
V=(4)AL
​Go Constant(2-Phase 4-Wire OS)
K=4(P2)ρLPloss(Vac2)

How to Evaluate Line Losses using Area of X-Section(2-Phase 4-Wire OS)?

Line Losses using Area of X-Section(2-Phase 4-Wire OS) evaluator uses Line Losses = (Length of Overhead AC Wire*Resistivity*(Power Transmitted^2))/(2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*((cos(Phase Difference))^2)) to evaluate the Line Losses, The Line Losses using Area of X-section(2-phase 4-wire OS) formula is defined as the loss of electric energy due to the heating of line wires by the current. Line Losses is denoted by Ploss symbol.

How to evaluate Line Losses using Area of X-Section(2-Phase 4-Wire OS) using this online evaluator? To use this online evaluator for Line Losses using Area of X-Section(2-Phase 4-Wire OS), enter Length of Overhead AC Wire (L), Resistivity (ρ), Power Transmitted (P), Area of Overhead AC Wire (A), Maximum Voltage Overhead AC (Vm) & Phase Difference (Φ) and hit the calculate button.

FAQs on Line Losses using Area of X-Section(2-Phase 4-Wire OS)

What is the formula to find Line Losses using Area of X-Section(2-Phase 4-Wire OS)?
The formula of Line Losses using Area of X-Section(2-Phase 4-Wire OS) is expressed as Line Losses = (Length of Overhead AC Wire*Resistivity*(Power Transmitted^2))/(2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*((cos(Phase Difference))^2)). Here is an example- 0.031424 = (10.63*1.7E-05*(890^2))/(2*0.79*(62^2)*((cos(0.5235987755982))^2)).
How to calculate Line Losses using Area of X-Section(2-Phase 4-Wire OS)?
With Length of Overhead AC Wire (L), Resistivity (ρ), Power Transmitted (P), Area of Overhead AC Wire (A), Maximum Voltage Overhead AC (Vm) & Phase Difference (Φ) we can find Line Losses using Area of X-Section(2-Phase 4-Wire OS) using the formula - Line Losses = (Length of Overhead AC Wire*Resistivity*(Power Transmitted^2))/(2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*((cos(Phase Difference))^2)). This formula also uses Cosine function(s).
What are the other ways to Calculate Line Losses?
Here are the different ways to Calculate Line Losses-
  • Line Losses=(4)*((Current Overhead AC)^2)*Resistance Overhead ACOpenImg
  • Line Losses=4*Resistance Overhead AC*(Current Overhead AC)^2OpenImg
Can the Line Losses using Area of X-Section(2-Phase 4-Wire OS) be negative?
Yes, the Line Losses using Area of X-Section(2-Phase 4-Wire OS), measured in Power can be negative.
Which unit is used to measure Line Losses using Area of X-Section(2-Phase 4-Wire OS)?
Line Losses using Area of X-Section(2-Phase 4-Wire OS) is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Line Losses using Area of X-Section(2-Phase 4-Wire OS) can be measured.
Copied!