Line Losses in End Condenser Method Formula

Fx Copy
LaTeX Copy
Power Loss in ECM is defined as the deviation in the power transferred from sending end to receiving end of a medium transmission line. Check FAQs
Ploss(ecm)=3RecmIs(ecm)2
Ploss(ecm) - Power Loss in ECM?Recm - Resistance in ECM?Is(ecm) - Sending End Current in ECM?

Line Losses in End Condenser Method Example

With values
With units
Only example

Here is how the Line Losses in End Condenser Method equation looks like with Values.

Here is how the Line Losses in End Condenser Method equation looks like with Units.

Here is how the Line Losses in End Condenser Method equation looks like.

84.48Edit=30.11Edit16Edit2
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Line Losses in End Condenser Method

Line Losses in End Condenser Method Solution

Follow our step by step solution on how to calculate Line Losses in End Condenser Method?

FIRST Step Consider the formula
Ploss(ecm)=3RecmIs(ecm)2
Next Step Substitute values of Variables
Ploss(ecm)=30.11Ω16A2
Next Step Prepare to Evaluate
Ploss(ecm)=30.11162
LAST Step Evaluate
Ploss(ecm)=84.48W

Line Losses in End Condenser Method Formula Elements

Variables
Power Loss in ECM
Power Loss in ECM is defined as the deviation in the power transferred from sending end to receiving end of a medium transmission line.
Symbol: Ploss(ecm)
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Resistance in ECM
Resistance in ECM is a measure of the opposition to current flow in a medium length transmission line.
Symbol: Recm
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Sending End Current in ECM
Sending End Current in ECM is defined as the amount of current injected into a medium transmission line from the source or injectors.
Symbol: Is(ecm)
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other formulas in End Condenser Method in Medium Line category

​Go Sending End Current in End Condenser Method
Is(ecm)=Ir(ecm)+Ic(ecm)
​Go Receiving End Current in End Condenser Method
Ir(ecm)=Is(ecm)-Ic(ecm)
​Go Capacitive Current in End Condenser Method
Ic(ecm)=Is(ecm)-Ir(ecm)
​Go Sending End Voltage in End Condenser Method
Vs(ecm)=Vr(ecm)+(Is(ecm)Zecm)

How to Evaluate Line Losses in End Condenser Method?

Line Losses in End Condenser Method evaluator uses Power Loss in ECM = 3*Resistance in ECM*Sending End Current in ECM^2 to evaluate the Power Loss in ECM, The Line Losses in End Condenser Method(ECM) formula is defined as the ratio of the power absorbed by the input circuit of a transducer to the power delivered to a specified load; usually expressed in decibels. Also known as power attenuation. Power Loss in ECM is denoted by Ploss(ecm) symbol.

How to evaluate Line Losses in End Condenser Method using this online evaluator? To use this online evaluator for Line Losses in End Condenser Method, enter Resistance in ECM (Recm) & Sending End Current in ECM (Is(ecm)) and hit the calculate button.

FAQs on Line Losses in End Condenser Method

What is the formula to find Line Losses in End Condenser Method?
The formula of Line Losses in End Condenser Method is expressed as Power Loss in ECM = 3*Resistance in ECM*Sending End Current in ECM^2. Here is an example- 84.48 = 3*0.11*16^2.
How to calculate Line Losses in End Condenser Method?
With Resistance in ECM (Recm) & Sending End Current in ECM (Is(ecm)) we can find Line Losses in End Condenser Method using the formula - Power Loss in ECM = 3*Resistance in ECM*Sending End Current in ECM^2.
Can the Line Losses in End Condenser Method be negative?
Yes, the Line Losses in End Condenser Method, measured in Power can be negative.
Which unit is used to measure Line Losses in End Condenser Method?
Line Losses in End Condenser Method is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Line Losses in End Condenser Method can be measured.
Copied!