Length when Coefficient of Permeability at Permeameter Experiment is Considered Formula

Fx Copy
LaTeX Copy
The Length referred as measurement or extent of something from end to end. Check FAQs
L=ΔHAKQ
L - Length?ΔH - Constant Head Difference?A - Cross-Sectional Area?K - Coefficient of Permeability at 20° C?Q - Discharge?

Length when Coefficient of Permeability at Permeameter Experiment is Considered Example

With values
With units
Only example

Here is how the Length when Coefficient of Permeability at Permeameter Experiment is Considered equation looks like with Values.

Here is how the Length when Coefficient of Permeability at Permeameter Experiment is Considered equation looks like with Units.

Here is how the Length when Coefficient of Permeability at Permeameter Experiment is Considered equation looks like.

4Edit=2Edit100Edit6Edit3Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Length when Coefficient of Permeability at Permeameter Experiment is Considered

Length when Coefficient of Permeability at Permeameter Experiment is Considered Solution

Follow our step by step solution on how to calculate Length when Coefficient of Permeability at Permeameter Experiment is Considered?

FIRST Step Consider the formula
L=ΔHAKQ
Next Step Substitute values of Variables
L=21006cm/s3m³/s
Next Step Convert Units
L=21000.06m/s3m³/s
Next Step Prepare to Evaluate
L=21000.063
LAST Step Evaluate
L=4m

Length when Coefficient of Permeability at Permeameter Experiment is Considered Formula Elements

Variables
Length
The Length referred as measurement or extent of something from end to end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Constant Head Difference
The Constant Head Difference is referred as difference between the hydraulic head or pressure difference separated by a small distance dl.
Symbol: ΔH
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Cross-Sectional Area
The Cross-Sectional Area is referred as product of width multiplied by average water depth.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Coefficient of Permeability at 20° C
The Coefficient of Permeability at 20° C refers to the measure of a porous medium’s ability to allow fluid flow through its voids.
Symbol: K
Measurement: SpeedUnit: cm/s
Note: Value should be greater than 0.
Discharge
The Discharge referred as volumetric flow rate of water that is transported through a given cross-sectional area. It includes any suspended solids, dissolved chemicals, or biologic material.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other formulas in Coefficient of Permeability category

​Go Coefficient of Permeability from Analogy of Laminar Flow (Hagen Poiseuille flow)
KH-P=C(dm2)γ1000μ
​Go Hagen Poiseuille Flow or Mean Particle Size of Porous Medium Laminar Flow through Conduit
dm=KH-PμC(γ1000)
​Go Unit weight of fluid
γ=ρfluidg
​Go Dynamic Viscosity of Fluid of Laminar Flow through Conduit or Hagen Poiseuille Flow
μ=(Cdm2)(γ1000KH-P)

How to Evaluate Length when Coefficient of Permeability at Permeameter Experiment is Considered?

Length when Coefficient of Permeability at Permeameter Experiment is Considered evaluator uses Length = (Constant Head Difference*Cross-Sectional Area*Coefficient of Permeability at 20° C)/Discharge to evaluate the Length, The Length when Coefficient of Permeability at Permeameter Experiment is Considered is defined as the effective length of the cross-sectional area or catchment area of consideration. Length is denoted by L symbol.

How to evaluate Length when Coefficient of Permeability at Permeameter Experiment is Considered using this online evaluator? To use this online evaluator for Length when Coefficient of Permeability at Permeameter Experiment is Considered, enter Constant Head Difference (ΔH), Cross-Sectional Area (A), Coefficient of Permeability at 20° C (K) & Discharge (Q) and hit the calculate button.

FAQs on Length when Coefficient of Permeability at Permeameter Experiment is Considered

What is the formula to find Length when Coefficient of Permeability at Permeameter Experiment is Considered?
The formula of Length when Coefficient of Permeability at Permeameter Experiment is Considered is expressed as Length = (Constant Head Difference*Cross-Sectional Area*Coefficient of Permeability at 20° C)/Discharge. Here is an example- 4 = (2*100*0.06)/3.
How to calculate Length when Coefficient of Permeability at Permeameter Experiment is Considered?
With Constant Head Difference (ΔH), Cross-Sectional Area (A), Coefficient of Permeability at 20° C (K) & Discharge (Q) we can find Length when Coefficient of Permeability at Permeameter Experiment is Considered using the formula - Length = (Constant Head Difference*Cross-Sectional Area*Coefficient of Permeability at 20° C)/Discharge.
Can the Length when Coefficient of Permeability at Permeameter Experiment is Considered be negative?
No, the Length when Coefficient of Permeability at Permeameter Experiment is Considered, measured in Length cannot be negative.
Which unit is used to measure Length when Coefficient of Permeability at Permeameter Experiment is Considered?
Length when Coefficient of Permeability at Permeameter Experiment is Considered is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length when Coefficient of Permeability at Permeameter Experiment is Considered can be measured.
Copied!