Fx Copy
LaTeX Copy
Length of Overhead AC Wire is the total length of the wire from one end to other end. Check FAQs
L=3VPloss(cos(Φ)Vm)27ρ(P2)
L - Length of Overhead AC Wire?V - Volume of Conductor?Ploss - Line Losses?Φ - Phase Difference?Vm - Maximum Voltage Overhead AC?ρ - Resistivity?P - Power Transmitted?

Length using Volume of Conductor Material (3-Phase 4-Wire OS) Example

With values
With units
Only example

Here is how the Length using Volume of Conductor Material (3-Phase 4-Wire OS) equation looks like with Values.

Here is how the Length using Volume of Conductor Material (3-Phase 4-Wire OS) equation looks like with Units.

Here is how the Length using Volume of Conductor Material (3-Phase 4-Wire OS) equation looks like.

19634.15Edit=326Edit8.23Edit(cos(30Edit)62Edit)271.7E-5Edit(890Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Length using Volume of Conductor Material (3-Phase 4-Wire OS)

Length using Volume of Conductor Material (3-Phase 4-Wire OS) Solution

Follow our step by step solution on how to calculate Length using Volume of Conductor Material (3-Phase 4-Wire OS)?

FIRST Step Consider the formula
L=3VPloss(cos(Φ)Vm)27ρ(P2)
Next Step Substitute values of Variables
L=3268.23W(cos(30°)62V)271.7E-5Ω*m(890W2)
Next Step Convert Units
L=3268.23W(cos(0.5236rad)62V)271.7E-5Ω*m(890W2)
Next Step Prepare to Evaluate
L=3268.23(cos(0.5236)62)271.7E-5(8902)
Next Step Evaluate
L=19634.1500468386m
LAST Step Rounding Answer
L=19634.15m

Length using Volume of Conductor Material (3-Phase 4-Wire OS) Formula Elements

Variables
Functions
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Volume of Conductor
Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line.
Symbol: V
Measurement: VolumeUnit:
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
Maximum Voltage Overhead AC
Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead ac line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other Formulas to find Length of Overhead AC Wire

​Go Length of Wire using Area of X-Section(3-Phase 4-Wire OS)
L=3A(Vm2)Ploss(cos(Φ))22ρ(P2)
​Go Length of Wire using Resistance (3-Phase 4-Wire OS)
L=RAρ

Other formulas in Wire Parameters category

​Go Area of X-Section(3-Phase 4-Wire OS)
A=2(P2)ρL((cos(Φ))2)Ploss3(Vm2)
​Go Constant(3-Phase 4-Wire OS)
K=4(P2)ρ(L2)Ploss(Vm2)

How to Evaluate Length using Volume of Conductor Material (3-Phase 4-Wire OS)?

Length using Volume of Conductor Material (3-Phase 4-Wire OS) evaluator uses Length of Overhead AC Wire = 3*Volume of Conductor*Line Losses*(cos(Phase Difference)*Maximum Voltage Overhead AC)^2/(7*Resistivity*(Power Transmitted^2)) to evaluate the Length of Overhead AC Wire, The Length using Volume of Conductor Material (3-phase 4-wire OS) formula is defined as the total length of the wire that used in the 3-phase 4-wire system. Length of Overhead AC Wire is denoted by L symbol.

How to evaluate Length using Volume of Conductor Material (3-Phase 4-Wire OS) using this online evaluator? To use this online evaluator for Length using Volume of Conductor Material (3-Phase 4-Wire OS), enter Volume of Conductor (V), Line Losses (Ploss), Phase Difference (Φ), Maximum Voltage Overhead AC (Vm), Resistivity (ρ) & Power Transmitted (P) and hit the calculate button.

FAQs on Length using Volume of Conductor Material (3-Phase 4-Wire OS)

What is the formula to find Length using Volume of Conductor Material (3-Phase 4-Wire OS)?
The formula of Length using Volume of Conductor Material (3-Phase 4-Wire OS) is expressed as Length of Overhead AC Wire = 3*Volume of Conductor*Line Losses*(cos(Phase Difference)*Maximum Voltage Overhead AC)^2/(7*Resistivity*(Power Transmitted^2)). Here is an example- 19634.15 = 3*26*8.23*(cos(0.5235987755982)*62)^2/(7*1.7E-05*(890^2)).
How to calculate Length using Volume of Conductor Material (3-Phase 4-Wire OS)?
With Volume of Conductor (V), Line Losses (Ploss), Phase Difference (Φ), Maximum Voltage Overhead AC (Vm), Resistivity (ρ) & Power Transmitted (P) we can find Length using Volume of Conductor Material (3-Phase 4-Wire OS) using the formula - Length of Overhead AC Wire = 3*Volume of Conductor*Line Losses*(cos(Phase Difference)*Maximum Voltage Overhead AC)^2/(7*Resistivity*(Power Transmitted^2)). This formula also uses Cosine (cos) function(s).
What are the other ways to Calculate Length of Overhead AC Wire?
Here are the different ways to Calculate Length of Overhead AC Wire-
  • Length of Overhead AC Wire=3*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2)/(2*Resistivity*(Power Transmitted^2))OpenImg
  • Length of Overhead AC Wire=(Resistance Overhead AC*Area of Overhead AC Wire)/ResistivityOpenImg
Can the Length using Volume of Conductor Material (3-Phase 4-Wire OS) be negative?
No, the Length using Volume of Conductor Material (3-Phase 4-Wire OS), measured in Length cannot be negative.
Which unit is used to measure Length using Volume of Conductor Material (3-Phase 4-Wire OS)?
Length using Volume of Conductor Material (3-Phase 4-Wire OS) is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length using Volume of Conductor Material (3-Phase 4-Wire OS) can be measured.
Copied!