Fx Copy
LaTeX Copy
Length of Wire DC is the measurement or extent of something from end to end. Check FAQs
l=VPlineVm2(5)ρ(P2)
l - Length of Wire DC?V - Volume Of Conductor?Pline - Line Losses?Vm - Maximum Voltage?ρ - Resistivity?P - Power Transmitted?

Length using Volume of Conductor Material(DC Three-Wire US) Example

With values
With units
Only example

Here is how the Length using Volume of Conductor Material(DC Three-Wire US) equation looks like with Values.

Here is how the Length using Volume of Conductor Material(DC Three-Wire US) equation looks like with Units.

Here is how the Length using Volume of Conductor Material(DC Three-Wire US) equation looks like.

99.41Edit=35Edit0.6Edit60Edit2(5)1.7E-5Edit(300Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Length using Volume of Conductor Material(DC Three-Wire US)

Length using Volume of Conductor Material(DC Three-Wire US) Solution

Follow our step by step solution on how to calculate Length using Volume of Conductor Material(DC Three-Wire US)?

FIRST Step Consider the formula
l=VPlineVm2(5)ρ(P2)
Next Step Substitute values of Variables
l=350.6W60V2(5)1.7E-5Ω*m(300W2)
Next Step Prepare to Evaluate
l=350.6602(5)1.7E-5(3002)
Next Step Evaluate
l=99.4100243495417m
LAST Step Rounding Answer
l=99.41m

Length using Volume of Conductor Material(DC Three-Wire US) Formula Elements

Variables
Functions
Length of Wire DC
Length of Wire DC is the measurement or extent of something from end to end.
Symbol: l
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Volume Of Conductor
Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Symbol: V
Measurement: VolumeUnit:
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the losses that are produced in the line.
Symbol: Pline
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage
Maximum Voltage the highest voltage rating for electrical devices.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Length of Wire DC

​Go Length using Area of X-Section (DC Three-Wire US)
l=APlineVm22ρ(P2)
​Go Length using Line Losses (DC Three-Wire US)
l=APline2ρ(C12)

Other formulas in Wire Parameters category

​Go Area of X-section using Volume of Conductor Material(DC Three-Wire US)
A=V2.5l
​Go Line Losses using Volume of Conductor Material(DC Three-Wire US)
Pline=5ρ(Pl)2V(Vm2)
​Go Constant using Volume of Conductor Material(DC Three-Wire US)
K=V1.25
​Go Volume of Conductor Material using Area and Length(DC Three-Wire US)
V=2.5Al

How to Evaluate Length using Volume of Conductor Material(DC Three-Wire US)?

Length using Volume of Conductor Material(DC Three-Wire US) evaluator uses Length of Wire DC = sqrt(Volume Of Conductor*Line Losses*(Maximum Voltage^2)/((5)*Resistivity*(Power Transmitted^2))) to evaluate the Length of Wire DC, The Length using Volume of Conductor Material(DC Three-Wire US) formula is defined as the total length of the wire that used in the 3-wire dc system. Length of Wire DC is denoted by l symbol.

How to evaluate Length using Volume of Conductor Material(DC Three-Wire US) using this online evaluator? To use this online evaluator for Length using Volume of Conductor Material(DC Three-Wire US), enter Volume Of Conductor (V), Line Losses (Pline), Maximum Voltage (Vm), Resistivity (ρ) & Power Transmitted (P) and hit the calculate button.

FAQs on Length using Volume of Conductor Material(DC Three-Wire US)

What is the formula to find Length using Volume of Conductor Material(DC Three-Wire US)?
The formula of Length using Volume of Conductor Material(DC Three-Wire US) is expressed as Length of Wire DC = sqrt(Volume Of Conductor*Line Losses*(Maximum Voltage^2)/((5)*Resistivity*(Power Transmitted^2))). Here is an example- 99.41002 = sqrt(35*0.6*(60^2)/((5)*1.7E-05*(300^2))).
How to calculate Length using Volume of Conductor Material(DC Three-Wire US)?
With Volume Of Conductor (V), Line Losses (Pline), Maximum Voltage (Vm), Resistivity (ρ) & Power Transmitted (P) we can find Length using Volume of Conductor Material(DC Three-Wire US) using the formula - Length of Wire DC = sqrt(Volume Of Conductor*Line Losses*(Maximum Voltage^2)/((5)*Resistivity*(Power Transmitted^2))). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Length of Wire DC?
Here are the different ways to Calculate Length of Wire DC-
  • Length of Wire DC=Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*(Power Transmitted^2))OpenImg
  • Length of Wire DC=Area of underground dc wire*Line Losses/(2*Resistivity*(Current underground DC^2))OpenImg
Can the Length using Volume of Conductor Material(DC Three-Wire US) be negative?
No, the Length using Volume of Conductor Material(DC Three-Wire US), measured in Length cannot be negative.
Which unit is used to measure Length using Volume of Conductor Material(DC Three-Wire US)?
Length using Volume of Conductor Material(DC Three-Wire US) is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length using Volume of Conductor Material(DC Three-Wire US) can be measured.
Copied!