Fx Copy
LaTeX Copy
Length of Wire DC is the total length of the wire from one end to other end. Check FAQs
L=VPlossVm2ρ(P2)
L - Length of Wire DC?V - Volume of Conductor?Ploss - Line Losses?Vm - Maximum Voltage Overhead DC?ρ - Resistivity?P - Power Transmitted?

Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) Example

With values
With units
Only example

Here is how the Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) equation looks like with Values.

Here is how the Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) equation looks like with Units.

Here is how the Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) equation looks like.

69.6818Edit=26Edit0.74Edit60.26Edit21.7E-5Edit(920Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS)

Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) Solution

Follow our step by step solution on how to calculate Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS)?

FIRST Step Consider the formula
L=VPlossVm2ρ(P2)
Next Step Substitute values of Variables
L=260.74W60.26V21.7E-5Ω*m(920W2)
Next Step Prepare to Evaluate
L=260.7460.2621.7E-5(9202)
Next Step Evaluate
L=69.6818019960145m
LAST Step Rounding Answer
L=69.6818m

Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) Formula Elements

Variables
Functions
Length of Wire DC
Length of Wire DC is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Volume of Conductor
Volume of Conductor is the total volume of the material used to make the conductor of an overhead dc line.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead DC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage Overhead DC
Maximum Voltage Overhead DC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is defined as the product of current and voltage phasor in a overhead dc line at the receiving end.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Length of Wire DC

​Go Length of Wire using Line Losses(Two-Wire Mid-Point Earthed)
L=(Vm2)Ploss2A(P2)ρ

Other formulas in Wire Parameters category

​Go Line Losses(Two-Wire Mid-Point Earthed)
Ploss=2R(I2)
​Go Area of X-Section using Line Losses(Two-Wire Mid-Point Earthed)
A=(P2)ρLPloss2(Vm2)
​Go Volume using K(Two-Wire Mid-Point Earthed)
V=(0.25)K
​Go Volume of Conductor Material(Two-Wire Mid-Point Earthed)
V=(2)AL

How to Evaluate Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS)?

Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) evaluator uses Length of Wire DC = sqrt(Volume of Conductor*Line Losses*(Maximum Voltage Overhead DC^2)/(Resistivity*(Power Transmitted^2))) to evaluate the Length of Wire DC, The Length using Volume of Conductor Material(2-Wire Mid-point Earthed OS) formula is defined as the total length of the wire that used in the two-wire mid-point earthed system. Length of Wire DC is denoted by L symbol.

How to evaluate Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) using this online evaluator? To use this online evaluator for Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS), enter Volume of Conductor (V), Line Losses (Ploss), Maximum Voltage Overhead DC (Vm), Resistivity (ρ) & Power Transmitted (P) and hit the calculate button.

FAQs on Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS)

What is the formula to find Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS)?
The formula of Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) is expressed as Length of Wire DC = sqrt(Volume of Conductor*Line Losses*(Maximum Voltage Overhead DC^2)/(Resistivity*(Power Transmitted^2))). Here is an example- 69.6818 = sqrt(26*0.74*(60.26^2)/(1.7E-05*(920^2))).
How to calculate Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS)?
With Volume of Conductor (V), Line Losses (Ploss), Maximum Voltage Overhead DC (Vm), Resistivity (ρ) & Power Transmitted (P) we can find Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) using the formula - Length of Wire DC = sqrt(Volume of Conductor*Line Losses*(Maximum Voltage Overhead DC^2)/(Resistivity*(Power Transmitted^2))). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Length of Wire DC?
Here are the different ways to Calculate Length of Wire DC-
  • Length of Wire DC=(Maximum Voltage Overhead DC^2)*Line Losses*2*Area of Overhead DC Wire/((Power Transmitted^2)*Resistivity)OpenImg
Can the Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) be negative?
No, the Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS), measured in Length cannot be negative.
Which unit is used to measure Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS)?
Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length using Volume of Conductor Material(2-Wire Mid-Point Earthed OS) can be measured.
Copied!