Length of Underground AC Wire is the total length of the wire from one end to other end. Check FAQs
L=R2Aρ
L - Length of Underground AC Wire?R - Resistance Underground AC?A - Area of Underground AC Wire?ρ - Resistivity?

Length using Resistance of Natural Wire (2-Phase 3-Wire US) Example

With values
With units
Only example

Here is how the Length using Resistance of Natural Wire (2-Phase 3-Wire US) equation looks like with Values.

Here is how the Length using Resistance of Natural Wire (2-Phase 3-Wire US) equation looks like with Units.

Here is how the Length using Resistance of Natural Wire (2-Phase 3-Wire US) equation looks like.

532409.8117Edit=5Edit21.28Edit1.7E-5Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Length using Resistance of Natural Wire (2-Phase 3-Wire US)

Length using Resistance of Natural Wire (2-Phase 3-Wire US) Solution

Follow our step by step solution on how to calculate Length using Resistance of Natural Wire (2-Phase 3-Wire US)?

FIRST Step Consider the formula
L=R2Aρ
Next Step Substitute values of Variables
L=5Ω21.281.7E-5Ω*m
Next Step Prepare to Evaluate
L=521.281.7E-5
Next Step Evaluate
L=532409.81171693m
LAST Step Rounding Answer
L=532409.8117m

Length using Resistance of Natural Wire (2-Phase 3-Wire US) Formula Elements

Variables
Functions
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Resistance Underground AC
Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other Formulas to find Length of Underground AC Wire

​Go Length using Volume of Conductor Material (2 Phase 3 Wire US)
L=VPloss(cos(Φ)Vm)2ρ((2+2)P2)
​Go Length using Line Losses (2-Phase 3-Wire US)
L=PlossA(Vmcos(Φ))2(2+2)(P2)ρ

Other formulas in Wire Parameters category

​Go Line Losses using Volume of Conductor Material (2 Phase 3 Wire US)
Ploss=((2+2)P)2ρ(L)2(Vmcos(Φ))2V
​Go Constant using Volume of Conductor Material (2 Phase 3 Wire US)
K=V(cos(Φ))22.914
​Go Area of X Section using Volume of Conductor Material (2 Phase 3 Wire US)
A=V(2+2)L
​Go Angle of PF using Volume of Conductor Material (2 Phase 3 Wire US)
Φ=acos((2.914)KV)

How to Evaluate Length using Resistance of Natural Wire (2-Phase 3-Wire US)?

Length using Resistance of Natural Wire (2-Phase 3-Wire US) evaluator uses Length of Underground AC Wire = (Resistance Underground AC*sqrt(2)*Area of Underground AC Wire)/(Resistivity) to evaluate the Length of Underground AC Wire, The Length using Resistance of Natural Wire (2-Phase 3-Wire US) formula is defined as the total length of the wire that used in the two-phase three-wire Underground system. Length of Underground AC Wire is denoted by L symbol.

How to evaluate Length using Resistance of Natural Wire (2-Phase 3-Wire US) using this online evaluator? To use this online evaluator for Length using Resistance of Natural Wire (2-Phase 3-Wire US), enter Resistance Underground AC (R), Area of Underground AC Wire (A) & Resistivity (ρ) and hit the calculate button.

FAQs on Length using Resistance of Natural Wire (2-Phase 3-Wire US)

What is the formula to find Length using Resistance of Natural Wire (2-Phase 3-Wire US)?
The formula of Length using Resistance of Natural Wire (2-Phase 3-Wire US) is expressed as Length of Underground AC Wire = (Resistance Underground AC*sqrt(2)*Area of Underground AC Wire)/(Resistivity). Here is an example- 532409.8 = (5*sqrt(2)*1.28)/(1.7E-05).
How to calculate Length using Resistance of Natural Wire (2-Phase 3-Wire US)?
With Resistance Underground AC (R), Area of Underground AC Wire (A) & Resistivity (ρ) we can find Length using Resistance of Natural Wire (2-Phase 3-Wire US) using the formula - Length of Underground AC Wire = (Resistance Underground AC*sqrt(2)*Area of Underground AC Wire)/(Resistivity). This formula also uses Square Root (sqrt) function(s).
What are the other ways to Calculate Length of Underground AC Wire?
Here are the different ways to Calculate Length of Underground AC Wire-
  • Length of Underground AC Wire=sqrt(Volume Of Conductor*Line Losses*(cos(Phase Difference)*Maximum Voltage Underground AC)^2/(Resistivity*((2+sqrt(2))*Power Transmitted^2)))OpenImg
  • Length of Underground AC Wire=Line Losses*Area of Underground AC Wire*(Maximum Voltage Underground AC*cos(Phase Difference))^2/((2+sqrt(2))*(Power Transmitted^2)*Resistivity)OpenImg
Can the Length using Resistance of Natural Wire (2-Phase 3-Wire US) be negative?
No, the Length using Resistance of Natural Wire (2-Phase 3-Wire US), measured in Length cannot be negative.
Which unit is used to measure Length using Resistance of Natural Wire (2-Phase 3-Wire US)?
Length using Resistance of Natural Wire (2-Phase 3-Wire US) is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length using Resistance of Natural Wire (2-Phase 3-Wire US) can be measured.
Copied!