Length of Underground AC Wire is the total length of the wire from one end to other end. Check FAQs
L=APloss2Iρ
L - Length of Underground AC Wire?A - Area of Underground AC Wire?Ploss - Line Losses?I - Current Underground AC?ρ - Resistivity?

Length using Line Losses (1 Phase 3 Wire US) Example

With values
With units
Only example

Here is how the Length using Line Losses (1 Phase 3 Wire US) equation looks like with Values.

Here is how the Length using Line Losses (1 Phase 3 Wire US) equation looks like with Units.

Here is how the Length using Line Losses (1 Phase 3 Wire US) equation looks like.

11168.6275Edit=1.28Edit2.67Edit29Edit1.7E-5Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Length using Line Losses (1 Phase 3 Wire US)

Length using Line Losses (1 Phase 3 Wire US) Solution

Follow our step by step solution on how to calculate Length using Line Losses (1 Phase 3 Wire US)?

FIRST Step Consider the formula
L=APloss2Iρ
Next Step Substitute values of Variables
L=1.282.67W29A1.7E-5Ω*m
Next Step Prepare to Evaluate
L=1.282.67291.7E-5
Next Step Evaluate
L=11168.6274509804m
LAST Step Rounding Answer
L=11168.6275m

Length using Line Losses (1 Phase 3 Wire US) Formula Elements

Variables
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current Underground AC
Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.

Other Formulas to find Length of Underground AC Wire

​Go Length using Volume of Conductor Material(1 Phase 3 Wire US)
L=VPloss(cos(Φ)Vm)2(10)ρ(P2)
​Go Length using Area of X Section (1 Phase 3 Wire US)
L=APloss(Vm2)cos(Φ)24(P2)ρ

Other formulas in Wire Parameters category

​Go Line Losses using Volume of Conductor Material(1 Phase 3 Wire US)
Ploss=10ρ(PL)2V((Vmcos(Φ))2)
​Go Constant using Volume of Conductor Material(1 Phase 3 Wire US)
K=Vcos(Φ)22.5
​Go Angle of PF using Volume of Conductor Material(1 Phase 3 Wire US)
Φ=acos(10ρ(PL)2PlossV((Vm)2))
​Go Angle using Area of X Section (1 Phase 3 Wire US)
Φ=acos((2PVm)ρLPlossA)

How to Evaluate Length using Line Losses (1 Phase 3 Wire US)?

Length using Line Losses (1 Phase 3 Wire US) evaluator uses Length of Underground AC Wire = Area of Underground AC Wire*Line Losses/(2*Current Underground AC*Resistivity) to evaluate the Length of Underground AC Wire, The Length using Line Losses (1 phase 3 wire US) formula is defined as the total length of the wire that used in the single-phase three-wire system. Length of Underground AC Wire is denoted by L symbol.

How to evaluate Length using Line Losses (1 Phase 3 Wire US) using this online evaluator? To use this online evaluator for Length using Line Losses (1 Phase 3 Wire US), enter Area of Underground AC Wire (A), Line Losses (Ploss), Current Underground AC (I) & Resistivity (ρ) and hit the calculate button.

FAQs on Length using Line Losses (1 Phase 3 Wire US)

What is the formula to find Length using Line Losses (1 Phase 3 Wire US)?
The formula of Length using Line Losses (1 Phase 3 Wire US) is expressed as Length of Underground AC Wire = Area of Underground AC Wire*Line Losses/(2*Current Underground AC*Resistivity). Here is an example- 11168.63 = 1.28*2.67/(2*9*1.7E-05).
How to calculate Length using Line Losses (1 Phase 3 Wire US)?
With Area of Underground AC Wire (A), Line Losses (Ploss), Current Underground AC (I) & Resistivity (ρ) we can find Length using Line Losses (1 Phase 3 Wire US) using the formula - Length of Underground AC Wire = Area of Underground AC Wire*Line Losses/(2*Current Underground AC*Resistivity).
What are the other ways to Calculate Length of Underground AC Wire?
Here are the different ways to Calculate Length of Underground AC Wire-
  • Length of Underground AC Wire=sqrt(Volume Of Conductor*Line Losses*(cos(Phase Difference)*Maximum Voltage Underground AC)^2/((10)*Resistivity*(Power Transmitted^2)))OpenImg
  • Length of Underground AC Wire=Area of Underground AC Wire*Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2)/(4*(Power Transmitted^2)*Resistivity)OpenImg
Can the Length using Line Losses (1 Phase 3 Wire US) be negative?
No, the Length using Line Losses (1 Phase 3 Wire US), measured in Length cannot be negative.
Which unit is used to measure Length using Line Losses (1 Phase 3 Wire US)?
Length using Line Losses (1 Phase 3 Wire US) is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length using Line Losses (1 Phase 3 Wire US) can be measured.
Copied!