Fx Copy
LaTeX Copy
Length of Underground AC Wire is the total length of the wire from one end to other end. Check FAQs
L=PlossA(Vmcos(Φ))24(P2)ρ
L - Length of Underground AC Wire?Ploss - Line Losses?A - Area of Underground AC Wire?Vm - Maximum Voltage Underground AC?Φ - Phase Difference?P - Power Transmitted?ρ - Resistivity?

Length using Line Losses (1-Phase 2-Wire US) Example

With values
With units
Only example

Here is how the Length using Line Losses (1-Phase 2-Wire US) equation looks like with Values.

Here is how the Length using Line Losses (1-Phase 2-Wire US) equation looks like with Units.

Here is how the Length using Line Losses (1-Phase 2-Wire US) equation looks like.

22155.7647Edit=2.67Edit1.28Edit(230Editcos(30Edit))24(300Edit2)1.7E-5Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Length using Line Losses (1-Phase 2-Wire US)

Length using Line Losses (1-Phase 2-Wire US) Solution

Follow our step by step solution on how to calculate Length using Line Losses (1-Phase 2-Wire US)?

FIRST Step Consider the formula
L=PlossA(Vmcos(Φ))24(P2)ρ
Next Step Substitute values of Variables
L=2.67W1.28(230Vcos(30°))24(300W2)1.7E-5Ω*m
Next Step Convert Units
L=2.67W1.28(230Vcos(0.5236rad))24(300W2)1.7E-5Ω*m
Next Step Prepare to Evaluate
L=2.671.28(230cos(0.5236))24(3002)1.7E-5
Next Step Evaluate
L=22155.7647058824m
LAST Step Rounding Answer
L=22155.7647m

Length using Line Losses (1-Phase 2-Wire US) Formula Elements

Variables
Functions
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Maximum Voltage Underground AC
Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other Formulas to find Length of Underground AC Wire

​Go Length using Area of X-Section (1-Phase 2-Wire US)
L=APloss(Vmcos(Φ))24(P2)ρ
​Go Length using Volume of Conductor Material (1-Phase 2-Wire US)
L=V2A

Other formulas in Wire Parameters category

​Go Area of X-Section (1-Phase 2-Wire US)
A=(4)ρL(P)2Ploss(Vmcos(Φ))2
​Go Voltage of Conductor Material (1-Phase 2-Wire US)
V=2K(cos(Φ))2

How to Evaluate Length using Line Losses (1-Phase 2-Wire US)?

Length using Line Losses (1-Phase 2-Wire US) evaluator uses Length of Underground AC Wire = Line Losses*Area of Underground AC Wire*(Maximum Voltage Underground AC*cos(Phase Difference))^2/(4*(Power Transmitted^2)*Resistivity) to evaluate the Length of Underground AC Wire, The Length using Line Losses (1-Phase 2-Wire US) formula is defined as the total length of the wire that used in the single-phase two-wire system. Length of Underground AC Wire is denoted by L symbol.

How to evaluate Length using Line Losses (1-Phase 2-Wire US) using this online evaluator? To use this online evaluator for Length using Line Losses (1-Phase 2-Wire US), enter Line Losses (Ploss), Area of Underground AC Wire (A), Maximum Voltage Underground AC (Vm), Phase Difference (Φ), Power Transmitted (P) & Resistivity (ρ) and hit the calculate button.

FAQs on Length using Line Losses (1-Phase 2-Wire US)

What is the formula to find Length using Line Losses (1-Phase 2-Wire US)?
The formula of Length using Line Losses (1-Phase 2-Wire US) is expressed as Length of Underground AC Wire = Line Losses*Area of Underground AC Wire*(Maximum Voltage Underground AC*cos(Phase Difference))^2/(4*(Power Transmitted^2)*Resistivity). Here is an example- 22155.76 = 2.67*1.28*(230*cos(0.5235987755982))^2/(4*(300^2)*1.7E-05).
How to calculate Length using Line Losses (1-Phase 2-Wire US)?
With Line Losses (Ploss), Area of Underground AC Wire (A), Maximum Voltage Underground AC (Vm), Phase Difference (Φ), Power Transmitted (P) & Resistivity (ρ) we can find Length using Line Losses (1-Phase 2-Wire US) using the formula - Length of Underground AC Wire = Line Losses*Area of Underground AC Wire*(Maximum Voltage Underground AC*cos(Phase Difference))^2/(4*(Power Transmitted^2)*Resistivity). This formula also uses Cosine (cos) function(s).
What are the other ways to Calculate Length of Underground AC Wire?
Here are the different ways to Calculate Length of Underground AC Wire-
  • Length of Underground AC Wire=Area of Underground AC Wire*Line Losses*(Maximum Voltage Underground AC*cos(Phase Difference))^2/(4*(Power Transmitted^2)*Resistivity)OpenImg
  • Length of Underground AC Wire=Volume Of Conductor/(2*Area of Underground AC Wire)OpenImg
  • Length of Underground AC Wire=(Line Losses*Area of Underground AC Wire)/(2*(Current Underground AC)^2*Resistivity)OpenImg
Can the Length using Line Losses (1-Phase 2-Wire US) be negative?
No, the Length using Line Losses (1-Phase 2-Wire US), measured in Length cannot be negative.
Which unit is used to measure Length using Line Losses (1-Phase 2-Wire US)?
Length using Line Losses (1-Phase 2-Wire US) is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length using Line Losses (1-Phase 2-Wire US) can be measured.
Copied!