Fx Copy
LaTeX Copy
Length of Wire DC is the measurement or extent of something from end to end. Check FAQs
l=APlineVm22ρ(P2)
l - Length of Wire DC?A - Area of underground dc wire?Pline - Line Losses?Vm - Maximum Voltage?ρ - Resistivity?P - Power Transmitted?

Length using Area of X-Section (DC Three-Wire US) Example

With values
With units
Only example

Here is how the Length using Area of X-Section (DC Three-Wire US) equation looks like with Values.

Here is how the Length using Area of X-Section (DC Three-Wire US) equation looks like with Units.

Here is how the Length using Area of X-Section (DC Three-Wire US) equation looks like.

225.8824Edit=0.32Edit0.6Edit60Edit221.7E-5Edit(300Edit2)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Length using Area of X-Section (DC Three-Wire US)

Length using Area of X-Section (DC Three-Wire US) Solution

Follow our step by step solution on how to calculate Length using Area of X-Section (DC Three-Wire US)?

FIRST Step Consider the formula
l=APlineVm22ρ(P2)
Next Step Substitute values of Variables
l=0.320.6W60V221.7E-5Ω*m(300W2)
Next Step Prepare to Evaluate
l=0.320.660221.7E-5(3002)
Next Step Evaluate
l=225.882352941176m
LAST Step Rounding Answer
l=225.8824m

Length using Area of X-Section (DC Three-Wire US) Formula Elements

Variables
Length of Wire DC
Length of Wire DC is the measurement or extent of something from end to end.
Symbol: l
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Area of underground dc wire
The Area of underground dc wire is the amount of two-dimensional space taken up by an object.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the losses that are produced in the line.
Symbol: Pline
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage
Maximum Voltage the highest voltage rating for electrical devices.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.

Other Formulas to find Length of Wire DC

​Go Length using Volume of Conductor Material(DC Three-Wire US)
l=VPlineVm2(5)ρ(P2)
​Go Length using Line Losses (DC Three-Wire US)
l=APline2ρ(C12)

Other formulas in Wire Parameters category

​Go Area of X-section using Volume of Conductor Material(DC Three-Wire US)
A=V2.5l
​Go Line Losses using Volume of Conductor Material(DC Three-Wire US)
Pline=5ρ(Pl)2V(Vm2)
​Go Constant using Volume of Conductor Material(DC Three-Wire US)
K=V1.25
​Go Volume of Conductor Material using Area and Length(DC Three-Wire US)
V=2.5Al

How to Evaluate Length using Area of X-Section (DC Three-Wire US)?

Length using Area of X-Section (DC Three-Wire US) evaluator uses Length of Wire DC = Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*(Power Transmitted^2)) to evaluate the Length of Wire DC, The Length using Area of X-Section (DC Three-Wire US) formula is defined as the total length of the wire that used in the DC Three-Wire system. Length of Wire DC is denoted by l symbol.

How to evaluate Length using Area of X-Section (DC Three-Wire US) using this online evaluator? To use this online evaluator for Length using Area of X-Section (DC Three-Wire US), enter Area of underground dc wire (A), Line Losses (Pline), Maximum Voltage (Vm), Resistivity (ρ) & Power Transmitted (P) and hit the calculate button.

FAQs on Length using Area of X-Section (DC Three-Wire US)

What is the formula to find Length using Area of X-Section (DC Three-Wire US)?
The formula of Length using Area of X-Section (DC Three-Wire US) is expressed as Length of Wire DC = Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*(Power Transmitted^2)). Here is an example- 225.8824 = 0.32*0.6*(60^2)/(2*1.7E-05*(300^2)).
How to calculate Length using Area of X-Section (DC Three-Wire US)?
With Area of underground dc wire (A), Line Losses (Pline), Maximum Voltage (Vm), Resistivity (ρ) & Power Transmitted (P) we can find Length using Area of X-Section (DC Three-Wire US) using the formula - Length of Wire DC = Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*Resistivity*(Power Transmitted^2)).
What are the other ways to Calculate Length of Wire DC?
Here are the different ways to Calculate Length of Wire DC-
  • Length of Wire DC=sqrt(Volume Of Conductor*Line Losses*(Maximum Voltage^2)/((5)*Resistivity*(Power Transmitted^2)))OpenImg
  • Length of Wire DC=Area of underground dc wire*Line Losses/(2*Resistivity*(Current underground DC^2))OpenImg
Can the Length using Area of X-Section (DC Three-Wire US) be negative?
No, the Length using Area of X-Section (DC Three-Wire US), measured in Length cannot be negative.
Which unit is used to measure Length using Area of X-Section (DC Three-Wire US)?
Length using Area of X-Section (DC Three-Wire US) is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length using Area of X-Section (DC Three-Wire US) can be measured.