Fx Copy
LaTeX Copy
Length of Wire DC is the measurement or extent of something from end to end. Check FAQs
l=APlineVm22(P2)ρ
l - Length of Wire DC?A - Area of underground dc wire?Pline - Line Losses?Vm - Maximum Voltage?P - Power Transmitted?ρ - Resistivity?

Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) Example

With values
With units
Only example

Here is how the Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) equation looks like with Values.

Here is how the Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) equation looks like with Units.

Here is how the Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) equation looks like.

225.8824Edit=0.32Edit0.6Edit60Edit22(300Edit2)1.7E-5Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Length using Area of X-Section (2-Wire Mid-Point Earthed DC US)

Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) Solution

Follow our step by step solution on how to calculate Length using Area of X-Section (2-Wire Mid-Point Earthed DC US)?

FIRST Step Consider the formula
l=APlineVm22(P2)ρ
Next Step Substitute values of Variables
l=0.320.6W60V22(300W2)1.7E-5Ω*m
Next Step Prepare to Evaluate
l=0.320.66022(3002)1.7E-5
Next Step Evaluate
l=225.882352941176m
LAST Step Rounding Answer
l=225.8824m

Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) Formula Elements

Variables
Length of Wire DC
Length of Wire DC is the measurement or extent of something from end to end.
Symbol: l
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Area of underground dc wire
The Area of underground dc wire is the amount of two-dimensional space taken up by an object.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the losses that are produced in the line.
Symbol: Pline
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage
Maximum Voltage the highest voltage rating for electrical devices.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.

Other Formulas to find Length of Wire DC

​Go Length using Volume of Conductor Material (2-Wire Mid-Point DC US)
l=VPline4(C12)(ρ)

Other formulas in Wire Parameters category

​Go Line Losses using Area of X-Section (2-Wire Mid-Point Earthed DC US)
Pline=2ρl(P2)A(Vm2cos(θ)2)
​Go Line Losses using Volume of Conductor Material (2-Wire Mid-Point DC US)
Pline=4ρP2l2Vm2V
​Go Area using Volume of Conductor Material (2-Wire Mid-Point DC US)
A=V2l
​Go Volume of Conductor Material (2-Wire Mid-Point DC US)
V=4ρ(P2)l2Pline(Vm2)

How to Evaluate Length using Area of X-Section (2-Wire Mid-Point Earthed DC US)?

Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) evaluator uses Length of Wire DC = Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*(Power Transmitted^2)*Resistivity) to evaluate the Length of Wire DC, The Length using Area of X-Section (2-wire Mid-point earthed DC US) formula is defined as the total length of the wire that used in the 2-wire Mid-point earthed DC system. Length of Wire DC is denoted by l symbol.

How to evaluate Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) using this online evaluator? To use this online evaluator for Length using Area of X-Section (2-Wire Mid-Point Earthed DC US), enter Area of underground dc wire (A), Line Losses (Pline), Maximum Voltage (Vm), Power Transmitted (P) & Resistivity (ρ) and hit the calculate button.

FAQs on Length using Area of X-Section (2-Wire Mid-Point Earthed DC US)

What is the formula to find Length using Area of X-Section (2-Wire Mid-Point Earthed DC US)?
The formula of Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) is expressed as Length of Wire DC = Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*(Power Transmitted^2)*Resistivity). Here is an example- 225.8824 = 0.32*0.6*(60^2)/(2*(300^2)*1.7E-05).
How to calculate Length using Area of X-Section (2-Wire Mid-Point Earthed DC US)?
With Area of underground dc wire (A), Line Losses (Pline), Maximum Voltage (Vm), Power Transmitted (P) & Resistivity (ρ) we can find Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) using the formula - Length of Wire DC = Area of underground dc wire*Line Losses*(Maximum Voltage^2)/(2*(Power Transmitted^2)*Resistivity).
What are the other ways to Calculate Length of Wire DC?
Here are the different ways to Calculate Length of Wire DC-
  • Length of Wire DC=sqrt((Volume Of Conductor*Line Losses)/(4*(Current underground DC^2)*(Resistivity)))OpenImg
Can the Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) be negative?
No, the Length using Area of X-Section (2-Wire Mid-Point Earthed DC US), measured in Length cannot be negative.
Which unit is used to measure Length using Area of X-Section (2-Wire Mid-Point Earthed DC US)?
Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length using Area of X-Section (2-Wire Mid-Point Earthed DC US) can be measured.
Copied!