Fx Copy
LaTeX Copy
Length of Underground AC Wire is the total length of the wire from one end to other end. Check FAQs
L=APloss(Vmcos(Φ))24(P2)ρ
L - Length of Underground AC Wire?A - Area of Underground AC Wire?Ploss - Line Losses?Vm - Maximum Voltage Underground AC?Φ - Phase Difference?P - Power Transmitted?ρ - Resistivity?

Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) Example

With values
With units
Only example

Here is how the Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) equation looks like with Values.

Here is how the Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) equation looks like with Units.

Here is how the Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) equation looks like.

22155.7647Edit=1.28Edit2.67Edit(230Editcos(30Edit))24(300Edit2)1.7E-5Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)

Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) Solution

Follow our step by step solution on how to calculate Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)?

FIRST Step Consider the formula
L=APloss(Vmcos(Φ))24(P2)ρ
Next Step Substitute values of Variables
L=1.282.67W(230Vcos(30°))24(300W2)1.7E-5Ω*m
Next Step Convert Units
L=1.282.67W(230Vcos(0.5236rad))24(300W2)1.7E-5Ω*m
Next Step Prepare to Evaluate
L=1.282.67(230cos(0.5236))24(3002)1.7E-5
Next Step Evaluate
L=22155.7647058824m
LAST Step Rounding Answer
L=22155.7647m

Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) Formula Elements

Variables
Functions
Length of Underground AC Wire
Length of Underground AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Area of Underground AC Wire
Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value can be positive or negative.
Line Losses
Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Maximum Voltage Underground AC
Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Symbol: Vm
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Phase Difference
Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Symbol: Φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.
Power Transmitted
Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Symbol: P
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)

Other Formulas to find Length of Underground AC Wire

​Go Length using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
L=PlossA2ρ(I2)
​Go Length using Volume of Conductor Material (1-Phase 2-Wire Mid-Point Earthed)
L=V2A

Other formulas in Wire Parameters category

​Go Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)
A=4ρLP2Ploss((Vmcos(Φ))2)
​Go Area using Line Losses (1-Phase 2-Wire Mid-Point Earthed)
A=2ρLPloss(I2)

How to Evaluate Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)?

Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) evaluator uses Length of Underground AC Wire = Area of Underground AC Wire*Line Losses*((Maximum Voltage Underground AC*cos(Phase Difference))^2)/(4*(Power Transmitted^2)*Resistivity) to evaluate the Length of Underground AC Wire, The Length using Area of X-Section (1-phase 2-wire Mid-point Earthed) formula is defined as the total length of the wire that used in the two-phase three-wire mid-point earthed Underground system. Length of Underground AC Wire is denoted by L symbol.

How to evaluate Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) using this online evaluator? To use this online evaluator for Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed), enter Area of Underground AC Wire (A), Line Losses (Ploss), Maximum Voltage Underground AC (Vm), Phase Difference (Φ), Power Transmitted (P) & Resistivity (ρ) and hit the calculate button.

FAQs on Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)

What is the formula to find Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)?
The formula of Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) is expressed as Length of Underground AC Wire = Area of Underground AC Wire*Line Losses*((Maximum Voltage Underground AC*cos(Phase Difference))^2)/(4*(Power Transmitted^2)*Resistivity). Here is an example- 22155.76 = 1.28*2.67*((230*cos(0.5235987755982))^2)/(4*(300^2)*1.7E-05).
How to calculate Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)?
With Area of Underground AC Wire (A), Line Losses (Ploss), Maximum Voltage Underground AC (Vm), Phase Difference (Φ), Power Transmitted (P) & Resistivity (ρ) we can find Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) using the formula - Length of Underground AC Wire = Area of Underground AC Wire*Line Losses*((Maximum Voltage Underground AC*cos(Phase Difference))^2)/(4*(Power Transmitted^2)*Resistivity). This formula also uses Cosine (cos) function(s).
What are the other ways to Calculate Length of Underground AC Wire?
Here are the different ways to Calculate Length of Underground AC Wire-
  • Length of Underground AC Wire=Line Losses*Area of Underground AC Wire/(2*Resistivity*(Current Underground AC^2))OpenImg
  • Length of Underground AC Wire=Volume Of Conductor/(2*Area of Underground AC Wire)OpenImg
Can the Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) be negative?
No, the Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed), measured in Length cannot be negative.
Which unit is used to measure Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed)?
Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length using Area of X-Section (1-Phase 2-Wire Mid-Point Earthed) can be measured.
Copied!