Length of Wire DC is the total length of the wire from one end to other end. Check FAQs
L=APloss(I2)ρ
L - Length of Wire DC?A - Area of Overhead DC Wire?Ploss - Line Losses?I - Current Overhead DC?ρ - Resistivity?

Length using Area of X-Section(DC 3-Wire) Example

With values
With units
Only example

Here is how the Length using Area of X-Section(DC 3-Wire) equation looks like with Values.

Here is how the Length using Area of X-Section(DC 3-Wire) equation looks like with Units.

Here is how the Length using Area of X-Section(DC 3-Wire) equation looks like.

2944.237Edit=0.65Edit0.74Edit(3.1Edit2)1.7E-5Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Length using Area of X-Section(DC 3-Wire)

Length using Area of X-Section(DC 3-Wire) Solution

Follow our step by step solution on how to calculate Length using Area of X-Section(DC 3-Wire)?

FIRST Step Consider the formula
L=APloss(I2)ρ
Next Step Substitute values of Variables
L=0.650.74W(3.1A2)1.7E-5Ω*m
Next Step Prepare to Evaluate
L=0.650.74(3.12)1.7E-5
Next Step Evaluate
L=2944.23700801861m
LAST Step Rounding Answer
L=2944.237m

Length using Area of X-Section(DC 3-Wire) Formula Elements

Variables
Length of Wire DC
Length of Wire DC is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Area of Overhead DC Wire
Area of Overhead DC Wire is defined as the cross-sectional area of the wire of an overhead DC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Line Losses
Line Losses is defined as the total losses occurring in an Overhead DC line when in use.
Symbol: Ploss
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Current Overhead DC
Current Overhead DC is defined as the current flowing through the overhead ac supply wire.
Symbol: I
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.

Other Formulas to find Length of Wire DC

​Go Length using Line Losses(DC 3-Wire)
L=PlossA2(I2)ρ
​Go Length using Volume of Conductor Material (DC 3-Wire)
L=V(2.5)A
​Go Length using Constant(DC 3-Wire)
L=KA

Other formulas in Wire Parameters category

​Go Area of X-Section using Line Losses(DC 3-Wire)
A=((I2)ρ)LPloss
​Go Volume of Conductor Material (DC 3-Wire)
V=((2.5)2)(I2)ρL2Ploss
​Go Area of X-Section using Volume of Conductor Material (DC 3-Wire)
A=V(2.5)L
​Go Line Losses using Volume of Conductor Material (DC 3-Wire)
Ploss=((P2)ρ(L2)V(Vm)2)

How to Evaluate Length using Area of X-Section(DC 3-Wire)?

Length using Area of X-Section(DC 3-Wire) evaluator uses Length of Wire DC = Area of Overhead DC Wire*Line Losses/((Current Overhead DC^2)*Resistivity) to evaluate the Length of Wire DC, The Length using Area of X-Section(DC 3-wire) formula is defined as the length of the wire used in the Three-Wire system. Length of Wire DC is denoted by L symbol.

How to evaluate Length using Area of X-Section(DC 3-Wire) using this online evaluator? To use this online evaluator for Length using Area of X-Section(DC 3-Wire), enter Area of Overhead DC Wire (A), Line Losses (Ploss), Current Overhead DC (I) & Resistivity (ρ) and hit the calculate button.

FAQs on Length using Area of X-Section(DC 3-Wire)

What is the formula to find Length using Area of X-Section(DC 3-Wire)?
The formula of Length using Area of X-Section(DC 3-Wire) is expressed as Length of Wire DC = Area of Overhead DC Wire*Line Losses/((Current Overhead DC^2)*Resistivity). Here is an example- 2944.237 = 0.65*0.74/((3.1^2)*1.7E-05).
How to calculate Length using Area of X-Section(DC 3-Wire)?
With Area of Overhead DC Wire (A), Line Losses (Ploss), Current Overhead DC (I) & Resistivity (ρ) we can find Length using Area of X-Section(DC 3-Wire) using the formula - Length of Wire DC = Area of Overhead DC Wire*Line Losses/((Current Overhead DC^2)*Resistivity).
What are the other ways to Calculate Length of Wire DC?
Here are the different ways to Calculate Length of Wire DC-
  • Length of Wire DC=Line Losses*Area of Overhead DC Wire/(2*(Current Overhead DC^2)*Resistivity)OpenImg
  • Length of Wire DC=Volume of Conductor/((2.5)*Area of Overhead DC Wire)OpenImg
  • Length of Wire DC=Constant Overhead DC/Area of Overhead DC WireOpenImg
Can the Length using Area of X-Section(DC 3-Wire) be negative?
No, the Length using Area of X-Section(DC 3-Wire), measured in Length cannot be negative.
Which unit is used to measure Length using Area of X-Section(DC 3-Wire)?
Length using Area of X-Section(DC 3-Wire) is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length using Area of X-Section(DC 3-Wire) can be measured.
Copied!