Fx Copy
LaTeX Copy
The length of a rectangular base plate for a wide-flange column. Check FAQs
N=m2(2Pu0.9FyBt2)
N - Length?m - Projection of Base Plate Beyond Flange?Pu - Factored Load?Fy - Yield Load?B - Width?t - Thickness?

Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web Example

With values
With units
Only example

Here is how the Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web equation looks like with Values.

Here is how the Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web equation looks like with Units.

Here is how the Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web equation looks like.

32.288Edit=75Edit2(239381Edit0.9350Edit40Edit33Edit2)

Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web Solution

Follow our step by step solution on how to calculate Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web?

FIRST Step Consider the formula
N=m2(2Pu0.9FyBt2)
Next Step Substitute values of Variables
N=75mm2(239381kN0.9350kN40mm33mm2)
Next Step Prepare to Evaluate
N=752(2393810.935040332)
Next Step Evaluate
N=0.0322879771743408m
Next Step Convert to Output's Unit
N=32.2879771743408mm
LAST Step Rounding Answer
N=32.288mm

Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web Formula Elements

Variables
Length
The length of a rectangular base plate for a wide-flange column.
Symbol: N
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Projection of Base Plate Beyond Flange
Projection of base plate beyond flange is distance between base plate beyond the flange and parallel to the web.
Symbol: m
Measurement: LengthUnit: mm
Note: Value can be positive or negative.
Factored Load
Factored Load is a load multiplied by a certain factor designated by codes of practice to determine the strength of a structural members.
Symbol: Pu
Measurement: ForceUnit: kN
Note: Value can be positive or negative.
Yield Load
Yield load is the load value at the point of yield; that is, where plastic deformation begins in stress strain curve.
Symbol: Fy
Measurement: ForceUnit: kN
Note: Value can be positive or negative.
Width
The width is parallel to the flanges.
Symbol: B
Measurement: LengthUnit: mm
Note: Value can be positive or negative.
Thickness
The thickness of the base plate.
Symbol: t
Measurement: LengthUnit: mm
Note: Value should be greater than 0.

Other Formulas to find Length

​Go Length Rectangular Base for Wide-Flange Column
N=A1B
​Go Length Rectangular Base for Projection of Base Plate beyond Flange and Perpendicular to Web
N=n2(2Pu0.9FyBt2)

Other formulas in Column Base Plate Design category

​Go Specified Compressive Strength of Concrete using Nominal Bearing Strength
f'c=(fp0.85)A1A2
​Go Nominal Bearing Strength of Concrete
fp=f'c0.85A2A1
​Go Area of Base Plate given Nominal Bearing Strength
A1=A2(fpf'c0.85)2
​Go Area of Supporting Concrete given Nominal Bearing Strength
A2=A1((fpf'c0.85)2)

How to Evaluate Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web?

Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web evaluator uses Length = Projection of Base Plate Beyond Flange^2*(2*Factored Load/(0.9*Yield Load*Width*Thickness^2)) to evaluate the Length, The Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web formula is defined as the extension of a base plate beyond a structural beam's flange, aligned with the beam's web. Length is denoted by N symbol.

How to evaluate Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web using this online evaluator? To use this online evaluator for Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web, enter Projection of Base Plate Beyond Flange (m), Factored Load (Pu), Yield Load (Fy), Width (B) & Thickness (t) and hit the calculate button.

FAQs on Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web

What is the formula to find Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web?
The formula of Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web is expressed as Length = Projection of Base Plate Beyond Flange^2*(2*Factored Load/(0.9*Yield Load*Width*Thickness^2)). Here is an example- 32287.98 = 0.075^2*(2*39381000/(0.9*350000*0.04*0.033^2)).
How to calculate Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web?
With Projection of Base Plate Beyond Flange (m), Factored Load (Pu), Yield Load (Fy), Width (B) & Thickness (t) we can find Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web using the formula - Length = Projection of Base Plate Beyond Flange^2*(2*Factored Load/(0.9*Yield Load*Width*Thickness^2)).
What are the other ways to Calculate Length?
Here are the different ways to Calculate Length-
  • Length=Area of Base Plate/WidthOpenImg
  • Length=Projection of Base Plate Beyond Edge^2*(2*Factored Load/(0.9*Yield Load*Width*Thickness^2))OpenImg
Can the Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web be negative?
No, the Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web, measured in Length cannot be negative.
Which unit is used to measure Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web?
Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web is usually measured using the Millimeter[mm] for Length. Meter[mm], Kilometer[mm], Decimeter[mm] are the few other units in which Length Rectangular Base for Projection of Base Plate beyond Flange and Parallel to Web can be measured.
Copied!