Fx Copy
LaTeX Copy
Length of Overhead AC Wire is the total length of the wire from one end to other end. Check FAQs
L=RAρ
L - Length of Overhead AC Wire?R - Resistance Overhead AC?A - Area of Overhead AC Wire?ρ - Resistivity?

Length of Wire using Resistance (3-Phase 4-Wire OS) Example

With values
With units
Only example

Here is how the Length of Wire using Resistance (3-Phase 4-Wire OS) equation looks like with Values.

Here is how the Length of Wire using Resistance (3-Phase 4-Wire OS) equation looks like with Units.

Here is how the Length of Wire using Resistance (3-Phase 4-Wire OS) equation looks like.

130.1176Edit=0.0028Edit0.79Edit1.7E-5Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Length of Wire using Resistance (3-Phase 4-Wire OS)

Length of Wire using Resistance (3-Phase 4-Wire OS) Solution

Follow our step by step solution on how to calculate Length of Wire using Resistance (3-Phase 4-Wire OS)?

FIRST Step Consider the formula
L=RAρ
Next Step Substitute values of Variables
L=0.0028Ω0.791.7E-5Ω*m
Next Step Prepare to Evaluate
L=0.00280.791.7E-5
Next Step Evaluate
L=130.117647058824m
LAST Step Rounding Answer
L=130.1176m

Length of Wire using Resistance (3-Phase 4-Wire OS) Formula Elements

Variables
Length of Overhead AC Wire
Length of Overhead AC Wire is the total length of the wire from one end to other end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Resistance Overhead AC
Resistance Overhead AC is defined as the property of the wire or line that opposes the flow of current through it.
Symbol: R
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Area of Overhead AC Wire
Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Symbol: A
Measurement: AreaUnit:
Note: Value should be greater than 0.
Resistivity
Resistivity is the measure of how strongly a material opposes the flow of current through them.
Symbol: ρ
Measurement: Electric ResistivityUnit: Ω*m
Note: Value can be positive or negative.

Other Formulas to find Length of Overhead AC Wire

​Go Length of Wire using Area of X-Section(3-Phase 4-Wire OS)
L=3A(Vm2)Ploss(cos(Φ))22ρ(P2)
​Go Length using Volume of Conductor Material (3-Phase 4-Wire OS)
L=3VPloss(cos(Φ)Vm)27ρ(P2)

Other formulas in Wire Parameters category

​Go Area of X-Section(3-Phase 4-Wire OS)
A=2(P2)ρL((cos(Φ))2)Ploss3(Vm2)
​Go Constant(3-Phase 4-Wire OS)
K=4(P2)ρ(L2)Ploss(Vm2)
​Go Line Losses(3-Phase 4-Wire OS)
Ploss=(3)((I)2)R
​Go Volume of Conductor Material(3-Phase 4-Wire OS)
V=(3.5)AL

How to Evaluate Length of Wire using Resistance (3-Phase 4-Wire OS)?

Length of Wire using Resistance (3-Phase 4-Wire OS) evaluator uses Length of Overhead AC Wire = (Resistance Overhead AC*Area of Overhead AC Wire)/Resistivity to evaluate the Length of Overhead AC Wire, The Length of Wire using Resistance (3-phase 4-wire OS) formula is defined as the total length of the wire that used in the three-phase four-wire system. Length of Overhead AC Wire is denoted by L symbol.

How to evaluate Length of Wire using Resistance (3-Phase 4-Wire OS) using this online evaluator? To use this online evaluator for Length of Wire using Resistance (3-Phase 4-Wire OS), enter Resistance Overhead AC (R), Area of Overhead AC Wire (A) & Resistivity (ρ) and hit the calculate button.

FAQs on Length of Wire using Resistance (3-Phase 4-Wire OS)

What is the formula to find Length of Wire using Resistance (3-Phase 4-Wire OS)?
The formula of Length of Wire using Resistance (3-Phase 4-Wire OS) is expressed as Length of Overhead AC Wire = (Resistance Overhead AC*Area of Overhead AC Wire)/Resistivity. Here is an example- 130.1176 = (0.0028*0.79)/1.7E-05.
How to calculate Length of Wire using Resistance (3-Phase 4-Wire OS)?
With Resistance Overhead AC (R), Area of Overhead AC Wire (A) & Resistivity (ρ) we can find Length of Wire using Resistance (3-Phase 4-Wire OS) using the formula - Length of Overhead AC Wire = (Resistance Overhead AC*Area of Overhead AC Wire)/Resistivity.
What are the other ways to Calculate Length of Overhead AC Wire?
Here are the different ways to Calculate Length of Overhead AC Wire-
  • Length of Overhead AC Wire=3*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2)/(2*Resistivity*(Power Transmitted^2))OpenImg
  • Length of Overhead AC Wire=3*Volume of Conductor*Line Losses*(cos(Phase Difference)*Maximum Voltage Overhead AC)^2/(7*Resistivity*(Power Transmitted^2))OpenImg
Can the Length of Wire using Resistance (3-Phase 4-Wire OS) be negative?
No, the Length of Wire using Resistance (3-Phase 4-Wire OS), measured in Length cannot be negative.
Which unit is used to measure Length of Wire using Resistance (3-Phase 4-Wire OS)?
Length of Wire using Resistance (3-Phase 4-Wire OS) is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length of Wire using Resistance (3-Phase 4-Wire OS) can be measured.
Copied!