Length of Tank given Overflow Rate Formula

Fx Copy
LaTeX Copy
Length is the measurement or extent of something from end to end. Check FAQs
L=(QSORw)
L - Length?Q - Discharge?SOR - Overflow Rate?w - Width?

Length of Tank given Overflow Rate Example

With values
With units
Only example

Here is how the Length of Tank given Overflow Rate equation looks like with Values.

Here is how the Length of Tank given Overflow Rate equation looks like with Units.

Here is how the Length of Tank given Overflow Rate equation looks like.

3.0102Edit=(3Edit0.4352Edit2.29Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Length of Tank given Overflow Rate

Length of Tank given Overflow Rate Solution

Follow our step by step solution on how to calculate Length of Tank given Overflow Rate?

FIRST Step Consider the formula
L=(QSORw)
Next Step Substitute values of Variables
L=(3m³/s0.4352m/s2.29m)
Next Step Prepare to Evaluate
L=(30.43522.29)
Next Step Evaluate
L=3.01021063447213m
LAST Step Rounding Answer
L=3.0102m

Length of Tank given Overflow Rate Formula Elements

Variables
Length
Length is the measurement or extent of something from end to end.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Discharge
Discharge is the rate of flow of a liquid.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Overflow Rate
Overflow Rate is the flow rate of water per unit surface area of the tank.
Symbol: SOR
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Width
Width is the horizontal measurement or dimension of a structure, feature, or area.
Symbol: w
Measurement: LengthUnit: m
Note: Value can be positive or negative.

Other formulas in Length of Tank category

​Go Overflow Rate given Discharge
SOR=QwL
​Go Rate of Flow given Detention Time
qflow=(VTd)
​Go Volume of Tank given Detention Time
V=Tdqflow
​Go Cross-section Area of Tank with known Velocity of Flow of Water
Acs=QVw

How to Evaluate Length of Tank given Overflow Rate?

Length of Tank given Overflow Rate evaluator uses Length = (Discharge/(Overflow Rate*Width)) to evaluate the Length, The Length of Tank given Overflow Rate formula is defined as the length dimension of a tank required to manage a specific overflow rate. This is important in the design of tanks used for storage and treatment of fluids, such as water or wastewater. Length is denoted by L symbol.

How to evaluate Length of Tank given Overflow Rate using this online evaluator? To use this online evaluator for Length of Tank given Overflow Rate, enter Discharge (Q), Overflow Rate (SOR) & Width (w) and hit the calculate button.

FAQs on Length of Tank given Overflow Rate

What is the formula to find Length of Tank given Overflow Rate?
The formula of Length of Tank given Overflow Rate is expressed as Length = (Discharge/(Overflow Rate*Width)). Here is an example- 1.091703 = (3/(0.4352*2.29)).
How to calculate Length of Tank given Overflow Rate?
With Discharge (Q), Overflow Rate (SOR) & Width (w) we can find Length of Tank given Overflow Rate using the formula - Length = (Discharge/(Overflow Rate*Width)).
Can the Length of Tank given Overflow Rate be negative?
No, the Length of Tank given Overflow Rate, measured in Length cannot be negative.
Which unit is used to measure Length of Tank given Overflow Rate?
Length of Tank given Overflow Rate is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length of Tank given Overflow Rate can be measured.
Copied!