Length of Side of Bearing Plate given Bursting Force for Square End Zone Formula

Fx Copy
LaTeX Copy
Side Length of Bearing Plate represented the length of the bearing plate in which the burst force is acting. Check FAQs
Ypo=-((FbstF)-0.320.3)Yo
Ypo - Side Length of Bearing Plate?Fbst - Prestress Bursting force?F - Prestressing Force?Yo - Traverse Dimension of End Zone?

Length of Side of Bearing Plate given Bursting Force for Square End Zone Example

With values
With units
Only example

Here is how the Length of Side of Bearing Plate given Bursting Force for Square End Zone equation looks like with Values.

Here is how the Length of Side of Bearing Plate given Bursting Force for Square End Zone equation looks like with Units.

Here is how the Length of Side of Bearing Plate given Bursting Force for Square End Zone equation looks like.

5Edit=-((68Edit400Edit)-0.320.3)10Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Structural Engineering » fx Length of Side of Bearing Plate given Bursting Force for Square End Zone

Length of Side of Bearing Plate given Bursting Force for Square End Zone Solution

Follow our step by step solution on how to calculate Length of Side of Bearing Plate given Bursting Force for Square End Zone?

FIRST Step Consider the formula
Ypo=-((FbstF)-0.320.3)Yo
Next Step Substitute values of Variables
Ypo=-((68kN400kN)-0.320.3)10cm
Next Step Prepare to Evaluate
Ypo=-((68400)-0.320.3)10
Next Step Evaluate
Ypo=0.05m
LAST Step Convert to Output's Unit
Ypo=5cm

Length of Side of Bearing Plate given Bursting Force for Square End Zone Formula Elements

Variables
Side Length of Bearing Plate
Side Length of Bearing Plate represented the length of the bearing plate in which the burst force is acting.
Symbol: Ypo
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Prestress Bursting force
The Prestress Bursting force represents the resultant of the tensile stress in a transverse direction.
Symbol: Fbst
Measurement: ForceUnit: kN
Note: Value should be greater than 0.
Prestressing Force
Prestressing Force is the force internally applied to the prestressed concrete section.
Symbol: F
Measurement: ForceUnit: kN
Note: Value should be greater than 0.
Traverse Dimension of End Zone
Traverse Dimension of End Zone can be defined as the measurement of bearing plate in traverse direction.
Symbol: Yo
Measurement: LengthUnit: cm
Note: Value should be greater than 0.

Other formulas in Post Tensioned Members category

​Go End Zone Reinforcement along Transmission Length
Ast=2.5Mtσalh
​Go Allowable Stress given End Zone Reinforcement
σal=2.5MtAsth
​Go Bursting Force for Square End Zone
Fbst=F(0.32-0.3(YpoYo))
​Go Prestress in Tendon given Bursting Force for Square End Zone
F=Fbst0.32-0.3(YpoYo)

How to Evaluate Length of Side of Bearing Plate given Bursting Force for Square End Zone?

Length of Side of Bearing Plate given Bursting Force for Square End Zone evaluator uses Side Length of Bearing Plate = -(((Prestress Bursting force/Prestressing Force)-0.32)/0.3)*Traverse Dimension of End Zone to evaluate the Side Length of Bearing Plate, The Length of Side of Bearing Plate given Bursting Force for Square End Zone formula is defined as the measurement of side length of bearing plate. Side Length of Bearing Plate is denoted by Ypo symbol.

How to evaluate Length of Side of Bearing Plate given Bursting Force for Square End Zone using this online evaluator? To use this online evaluator for Length of Side of Bearing Plate given Bursting Force for Square End Zone, enter Prestress Bursting force (Fbst), Prestressing Force (F) & Traverse Dimension of End Zone (Yo) and hit the calculate button.

FAQs on Length of Side of Bearing Plate given Bursting Force for Square End Zone

What is the formula to find Length of Side of Bearing Plate given Bursting Force for Square End Zone?
The formula of Length of Side of Bearing Plate given Bursting Force for Square End Zone is expressed as Side Length of Bearing Plate = -(((Prestress Bursting force/Prestressing Force)-0.32)/0.3)*Traverse Dimension of End Zone. Here is an example- 500 = -(((68000/400000)-0.32)/0.3)*0.1.
How to calculate Length of Side of Bearing Plate given Bursting Force for Square End Zone?
With Prestress Bursting force (Fbst), Prestressing Force (F) & Traverse Dimension of End Zone (Yo) we can find Length of Side of Bearing Plate given Bursting Force for Square End Zone using the formula - Side Length of Bearing Plate = -(((Prestress Bursting force/Prestressing Force)-0.32)/0.3)*Traverse Dimension of End Zone.
Can the Length of Side of Bearing Plate given Bursting Force for Square End Zone be negative?
No, the Length of Side of Bearing Plate given Bursting Force for Square End Zone, measured in Length cannot be negative.
Which unit is used to measure Length of Side of Bearing Plate given Bursting Force for Square End Zone?
Length of Side of Bearing Plate given Bursting Force for Square End Zone is usually measured using the Centimeter[cm] for Length. Meter[cm], Millimeter[cm], Kilometer[cm] are the few other units in which Length of Side of Bearing Plate given Bursting Force for Square End Zone can be measured.
Copied!