Fx Copy
LaTeX Copy
The Length refers to the measurement of the distance between two points. Check FAQs
L=HQwhv'
L - Length?H - Outer Height?Q - Discharge?w - Width?h - Height of Crack?v' - Falling Speed?

Length of Settling Zone given Height at Outlet Zone with respect to Discharge Example

With values
With units
Only example

Here is how the Length of Settling Zone given Height at Outlet Zone with respect to Discharge equation looks like with Values.

Here is how the Length of Settling Zone given Height at Outlet Zone with respect to Discharge equation looks like with Units.

Here is how the Length of Settling Zone given Height at Outlet Zone with respect to Discharge equation looks like.

14.7016Edit=40Edit1.01Edit2.29Edit12000Edit0.1Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Length of Settling Zone given Height at Outlet Zone with respect to Discharge

Length of Settling Zone given Height at Outlet Zone with respect to Discharge Solution

Follow our step by step solution on how to calculate Length of Settling Zone given Height at Outlet Zone with respect to Discharge?

FIRST Step Consider the formula
L=HQwhv'
Next Step Substitute values of Variables
L=40m1.01m³/s2.29m12000mm0.1m/s
Next Step Convert Units
L=40m1.01m³/s2.29m12m0.1m/s
Next Step Prepare to Evaluate
L=401.012.29120.1
Next Step Evaluate
L=14.7016011644833m
LAST Step Rounding Answer
L=14.7016m

Length of Settling Zone given Height at Outlet Zone with respect to Discharge Formula Elements

Variables
Length
The Length refers to the measurement of the distance between two points.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Outer Height
The Outer Height refers to the external vertical dimension of an object or structure.
Symbol: H
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Discharge
The Discharge refers to the volume of fluid (usually water) that flows through a given cross-sectional area per unit of time.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value can be positive or negative.
Width
The Width of a sedimentation tank refers to the horizontal dimension across the tank, typically measured perpendicular to the flow of water in a rectangular tank.
Symbol: w
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Height of Crack
The Height of Crack refers to the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress.
Symbol: h
Measurement: LengthUnit: mm
Note: Value should be greater than 0.
Falling Speed
The Falling Speed refers to the constant speed at which a particle falls through a fluid when the force of gravity is balanced by the drag force and buoyant force acting on the particle.
Symbol: v'
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.

Other Formulas to find Length

​Go Length of Settling Zone given Vertical Falling Speed in Sedimentation Tank
L=QVsw
​Go Length of Settling Zone given Detention Time
L=TdQwh
​Go Length of Settling Zone given Surface Area of Sedimentation Tank
L=Acsw

How to Evaluate Length of Settling Zone given Height at Outlet Zone with respect to Discharge?

Length of Settling Zone given Height at Outlet Zone with respect to Discharge evaluator uses Length = (Outer Height*Discharge)/(Width*Height of Crack*Falling Speed) to evaluate the Length, The Length of Settling Zone given Height at Outlet Zone with respect to Discharge formula is defined the horizontal distance along which water flows and particles settle before the clarified water exits the tank. Length is denoted by L symbol.

How to evaluate Length of Settling Zone given Height at Outlet Zone with respect to Discharge using this online evaluator? To use this online evaluator for Length of Settling Zone given Height at Outlet Zone with respect to Discharge, enter Outer Height (H), Discharge (Q), Width (w), Height of Crack (h) & Falling Speed (v') and hit the calculate button.

FAQs on Length of Settling Zone given Height at Outlet Zone with respect to Discharge

What is the formula to find Length of Settling Zone given Height at Outlet Zone with respect to Discharge?
The formula of Length of Settling Zone given Height at Outlet Zone with respect to Discharge is expressed as Length = (Outer Height*Discharge)/(Width*Height of Crack*Falling Speed). Here is an example- 14.7016 = (40*1.01)/(2.29*12*0.1).
How to calculate Length of Settling Zone given Height at Outlet Zone with respect to Discharge?
With Outer Height (H), Discharge (Q), Width (w), Height of Crack (h) & Falling Speed (v') we can find Length of Settling Zone given Height at Outlet Zone with respect to Discharge using the formula - Length = (Outer Height*Discharge)/(Width*Height of Crack*Falling Speed).
What are the other ways to Calculate Length?
Here are the different ways to Calculate Length-
  • Length=Discharge/(Settling Velocity*Width)OpenImg
  • Length=(Detention Time*Discharge)/(Width*Height of Crack)OpenImg
  • Length=Cross-Sectional Area/WidthOpenImg
Can the Length of Settling Zone given Height at Outlet Zone with respect to Discharge be negative?
No, the Length of Settling Zone given Height at Outlet Zone with respect to Discharge, measured in Length cannot be negative.
Which unit is used to measure Length of Settling Zone given Height at Outlet Zone with respect to Discharge?
Length of Settling Zone given Height at Outlet Zone with respect to Discharge is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length of Settling Zone given Height at Outlet Zone with respect to Discharge can be measured.
Copied!