Length of Primary Member using Collapse Prevention Level Formula

Fx Copy
LaTeX Copy
Length of Primary Member can be defined as the measurement of primary element in length. Check FAQs
Lp=(Cp107Ip32Ls)14
Lp - Length of Primary Member?Cp - Collapse Prevention Level?Ip - Moment of Inertia of Primary Member?Ls - Length of Secondary Member?

Length of Primary Member using Collapse Prevention Level Example

With values
With units
Only example

Here is how the Length of Primary Member using Collapse Prevention Level equation looks like with Values.

Here is how the Length of Primary Member using Collapse Prevention Level equation looks like with Units.

Here is how the Length of Primary Member using Collapse Prevention Level equation looks like.

1.5Edit=(95.29Edit10785Edit320.5Edit)14
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Design of Steel Structures » fx Length of Primary Member using Collapse Prevention Level

Length of Primary Member using Collapse Prevention Level Solution

Follow our step by step solution on how to calculate Length of Primary Member using Collapse Prevention Level?

FIRST Step Consider the formula
Lp=(Cp107Ip32Ls)14
Next Step Substitute values of Variables
Lp=(95.2910785mm⁴/mm320.5m)14
Next Step Convert Units
Lp=(95.291078.5E-8m⁴/m320.5m)14
Next Step Prepare to Evaluate
Lp=(95.291078.5E-8320.5)14
Next Step Evaluate
Lp=1.49998379603373m
LAST Step Rounding Answer
Lp=1.5m

Length of Primary Member using Collapse Prevention Level Formula Elements

Variables
Length of Primary Member
Length of Primary Member can be defined as the measurement of primary element in length.
Symbol: Lp
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Collapse Prevention Level
Collapse Prevention Level can be described as the building performance level which consists of the structural collapse prevention level with no consideration of nonstructural vulnerabilities.
Symbol: Cp
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Moment of Inertia of Primary Member
Moment of Inertia of Primary Member can be described as the quantity expressed by the body resisting angular acceleration.
Symbol: Ip
Measurement: Moment of Inertia per Unit LengthUnit: mm⁴/mm
Note: Value can be positive or negative.
Length of Secondary Member
Length of Secondary Member can be described as the measurement of the secondary element in length.
Symbol: Ls
Measurement: LengthUnit: m
Note: Value should be greater than 0.

Other formulas in Ponding Considerations in Buildings category

​Go Collapse Prevention Level
Cp=32Lp4Ls107Ip
​Go Capacity Spectrum
Cs=32SLs4107Is
​Go Length of Secondary Member using Collapse Prevention Level
Ls=Cp107Ip32Lp4
​Go Length of Secondary Member given Capacity Spectrum
Ls=(Cs107Is32S)14

How to Evaluate Length of Primary Member using Collapse Prevention Level?

Length of Primary Member using Collapse Prevention Level evaluator uses Length of Primary Member = ((Collapse Prevention Level*10^7*Moment of Inertia of Primary Member)/(32*Length of Secondary Member))^(1/4) to evaluate the Length of Primary Member, The Length of Primary Member using Collapse Prevention Level formula is defined as the measurement of the primary element in distance. Length of Primary Member is denoted by Lp symbol.

How to evaluate Length of Primary Member using Collapse Prevention Level using this online evaluator? To use this online evaluator for Length of Primary Member using Collapse Prevention Level, enter Collapse Prevention Level (Cp), Moment of Inertia of Primary Member (Ip) & Length of Secondary Member (Ls) and hit the calculate button.

FAQs on Length of Primary Member using Collapse Prevention Level

What is the formula to find Length of Primary Member using Collapse Prevention Level?
The formula of Length of Primary Member using Collapse Prevention Level is expressed as Length of Primary Member = ((Collapse Prevention Level*10^7*Moment of Inertia of Primary Member)/(32*Length of Secondary Member))^(1/4). Here is an example- 0.339477 = ((95.29*10^7*8.5E-08)/(32*0.5))^(1/4).
How to calculate Length of Primary Member using Collapse Prevention Level?
With Collapse Prevention Level (Cp), Moment of Inertia of Primary Member (Ip) & Length of Secondary Member (Ls) we can find Length of Primary Member using Collapse Prevention Level using the formula - Length of Primary Member = ((Collapse Prevention Level*10^7*Moment of Inertia of Primary Member)/(32*Length of Secondary Member))^(1/4).
Can the Length of Primary Member using Collapse Prevention Level be negative?
Yes, the Length of Primary Member using Collapse Prevention Level, measured in Length can be negative.
Which unit is used to measure Length of Primary Member using Collapse Prevention Level?
Length of Primary Member using Collapse Prevention Level is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length of Primary Member using Collapse Prevention Level can be measured.
Copied!