Length of Opening given Runoff Quantity with Full Gutter Flow Formula

Fx Copy
LaTeX Copy
The Length of Opening refers to the dimension of the structure that allows water to pass through. Check FAQs
Lo=Qro0.7(a+y)32
Lo - Length of Opening?Qro - Runoff Quantity?a - Depression in Curb Inlet?y - Depth of Flow at Inlet?

Length of Opening given Runoff Quantity with Full Gutter Flow Example

With values
With units
Only example

Here is how the Length of Opening given Runoff Quantity with Full Gutter Flow equation looks like with Values.

Here is how the Length of Opening given Runoff Quantity with Full Gutter Flow equation looks like with Units.

Here is how the Length of Opening given Runoff Quantity with Full Gutter Flow equation looks like.

7.0004Edit=329Edit0.7(4Edit+7.117Edit)32
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Length of Opening given Runoff Quantity with Full Gutter Flow

Length of Opening given Runoff Quantity with Full Gutter Flow Solution

Follow our step by step solution on how to calculate Length of Opening given Runoff Quantity with Full Gutter Flow?

FIRST Step Consider the formula
Lo=Qro0.7(a+y)32
Next Step Substitute values of Variables
Lo=329ft³/s0.7(4ft+7.117ft)32
Next Step Convert Units
Lo=9.3162m³/s0.7(1.2192m+2.1693m)32
Next Step Prepare to Evaluate
Lo=9.31620.7(1.2192+2.1693)32
Next Step Evaluate
Lo=2.13372719983356m
Next Step Convert to Output's Unit
Lo=7.0004173222606ft
LAST Step Rounding Answer
Lo=7.0004ft

Length of Opening given Runoff Quantity with Full Gutter Flow Formula Elements

Variables
Length of Opening
The Length of Opening refers to the dimension of the structure that allows water to pass through.
Symbol: Lo
Measurement: LengthUnit: ft
Note: Value should be greater than 0.
Runoff Quantity
The Runoff Quantity refers to the amount of water that storms bring to the earth.
Symbol: Qro
Measurement: Volumetric Flow RateUnit: ft³/s
Note: Value should be greater than 0.
Depression in Curb Inlet
The Depression in Curb Inlet refers to the height of depression at the curb achieved from the steeper grade of the gutter cross slope relative to the roadway cross-slope.
Symbol: a
Measurement: LengthUnit: ft
Note: Value can be positive or negative.
Depth of Flow at Inlet
The Depth of Flow at Inlet refers to the depth of water in a channel or conduit at the point where water enters a structure, such as a culvert, intake structure, or storm water inlet.
Symbol: y
Measurement: LengthUnit: ft
Note: Value can be positive or negative.

Other formulas in Disposing of Storm Water category

​Go Runoff Quantity with Full Gutter Flow
Qro=0.7Lo(a+y)32
​Go Depression in Curb Inlet given Runoff Quantity with Full Gutter flow
a=((Qro0.7Lo)23)-y
​Go Depth of Flow at Inlet given Runoff Quantity with Full Gutter Flow
y=((Qro0.7Lo)23)-a
​Go Inlet Capacity for Flow Depth
Qw=3Py32

How to Evaluate Length of Opening given Runoff Quantity with Full Gutter Flow?

Length of Opening given Runoff Quantity with Full Gutter Flow evaluator uses Length of Opening = Runoff Quantity/(0.7*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2)) to evaluate the Length of Opening, The Length of Opening given Runoff Quantity with Full Gutter Flow is defined as the opening length when we have a prior info of amount of the water flow per second, depression in curb and depth of flow at the inlet. Length of Opening is denoted by Lo symbol.

How to evaluate Length of Opening given Runoff Quantity with Full Gutter Flow using this online evaluator? To use this online evaluator for Length of Opening given Runoff Quantity with Full Gutter Flow, enter Runoff Quantity (Qro), Depression in Curb Inlet (a) & Depth of Flow at Inlet (y) and hit the calculate button.

FAQs on Length of Opening given Runoff Quantity with Full Gutter Flow

What is the formula to find Length of Opening given Runoff Quantity with Full Gutter Flow?
The formula of Length of Opening given Runoff Quantity with Full Gutter Flow is expressed as Length of Opening = Runoff Quantity/(0.7*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2)). Here is an example- 22.96725 = 9.3162425288798/(0.7*(1.21920000000488+2.16926160000868)^(3/2)).
How to calculate Length of Opening given Runoff Quantity with Full Gutter Flow?
With Runoff Quantity (Qro), Depression in Curb Inlet (a) & Depth of Flow at Inlet (y) we can find Length of Opening given Runoff Quantity with Full Gutter Flow using the formula - Length of Opening = Runoff Quantity/(0.7*(Depression in Curb Inlet+Depth of Flow at Inlet)^(3/2)).
Can the Length of Opening given Runoff Quantity with Full Gutter Flow be negative?
No, the Length of Opening given Runoff Quantity with Full Gutter Flow, measured in Length cannot be negative.
Which unit is used to measure Length of Opening given Runoff Quantity with Full Gutter Flow?
Length of Opening given Runoff Quantity with Full Gutter Flow is usually measured using the Foot[ft] for Length. Meter[ft], Millimeter[ft], Kilometer[ft] are the few other units in which Length of Opening given Runoff Quantity with Full Gutter Flow can be measured.
Copied!