L=0.1B1.1-(Φpφ)
L - Length of Footing?B - Width of Footing?Φp - Angle of Internal Friction For Plain Strain?φ - Angle of Internal Friction?

Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis Example

With values
With units
Only example

Here is how the Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis equation looks like with Values.

Here is how the Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis equation looks like with Units.

Here is how the Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis equation looks like.

0.4466Edit=0.12Edit1.1-(30Edit46Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Geotechnical Engineering » fx Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis

Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis Solution

Follow our step by step solution on how to calculate Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis?

FIRST Step Consider the formula
L=0.1B1.1-(Φpφ)
Next Step Substitute values of Variables
L=0.12m1.1-(30°46°)
Next Step Convert Units
L=0.12m1.1-(0.5236rad0.8029rad)
Next Step Prepare to Evaluate
L=0.121.1-(0.52360.8029)
Next Step Evaluate
L=0.446601941747572m
LAST Step Rounding Answer
L=0.4466m

Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis Formula Elements

Variables
Length of Footing
Length of Footing is the length of the larger dimension of the footing.
Symbol: L
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Width of Footing
Width of Footing is the shorter dimension of the footing.
Symbol: B
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Angle of Internal Friction For Plain Strain
Angle of Internal Friction For Plain Strain means angle of internal friction dependent on plain strain.
Symbol: Φp
Measurement: AngleUnit: °
Note: Value should be greater than 0.
Angle of Internal Friction
Angle of Internal Friction is the angle measured between the normal force and resultant force .
Symbol: φ
Measurement: AngleUnit: °
Note: Value should be greater than 0.

Other formulas in Bearing Capacity of Soils by Meyerhof's Analysis category

​Go Plane Strain Angle of Shearing Resistance by Meyerhof's Analysis
Φp=(1.1-0.1(BL))φ
​Go Triaxial Angle of Shearing Resistance by Meyerhof's Analysis
φ=Φp1.1-0.1(BL)
​Go Width of Footing given Angle of Shearing Resistance by Meyerhof's Analysis
B=(1.1-(Φpφ))(L0.1)
​Go Bearing Capacity Factor Dependent on Surcharge given Angle of Internal Friction
Nq=(exp(πtan(φπ180)))(tan((45+(φ2))π180))2

How to Evaluate Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis?

Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis evaluator uses Length of Footing = (0.1*Width of Footing)/(1.1-(Angle of Internal Friction For Plain Strain/Angle of Internal Friction)) to evaluate the Length of Footing, The Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis is defined as the value of length of footing when we have prior information of other parameters used. Length of Footing is denoted by L symbol.

How to evaluate Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis using this online evaluator? To use this online evaluator for Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis, enter Width of Footing (B), Angle of Internal Friction For Plain Strain p) & Angle of Internal Friction (φ) and hit the calculate button.

FAQs on Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis

What is the formula to find Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis?
The formula of Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis is expressed as Length of Footing = (0.1*Width of Footing)/(1.1-(Angle of Internal Friction For Plain Strain/Angle of Internal Friction)). Here is an example- 0.446602 = (0.1*2)/(1.1-(0.5235987755982/0.802851455917241)).
How to calculate Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis?
With Width of Footing (B), Angle of Internal Friction For Plain Strain p) & Angle of Internal Friction (φ) we can find Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis using the formula - Length of Footing = (0.1*Width of Footing)/(1.1-(Angle of Internal Friction For Plain Strain/Angle of Internal Friction)).
Can the Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis be negative?
Yes, the Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis, measured in Length can be negative.
Which unit is used to measure Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis?
Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length of Footing given Angle of Shearing Resistance by Meyerhof's Analysis can be measured.
Copied!