Length of Conduit after using Area of Pipe in Discharge Formula

Fx Copy
LaTeX Copy
Length of Pipe describes the length of the pipe in which the liquid is flowing. Check FAQs
Lpipe=C1HfVmax
Lpipe - Length of Pipe?C1 - Material Coefficient?Hf - Head under Flow?Vmax - Maximum Velocity?

Length of Conduit after using Area of Pipe in Discharge Example

With values
With units
Only example

Here is how the Length of Conduit after using Area of Pipe in Discharge equation looks like with Values.

Here is how the Length of Conduit after using Area of Pipe in Discharge equation looks like with Units.

Here is how the Length of Conduit after using Area of Pipe in Discharge equation looks like.

1.5Edit=9Edit5Edit30Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Hydraulics and Waterworks » fx Length of Conduit after using Area of Pipe in Discharge

Length of Conduit after using Area of Pipe in Discharge Solution

Follow our step by step solution on how to calculate Length of Conduit after using Area of Pipe in Discharge?

FIRST Step Consider the formula
Lpipe=C1HfVmax
Next Step Substitute values of Variables
Lpipe=95m30m/s
Next Step Prepare to Evaluate
Lpipe=9530
LAST Step Evaluate
Lpipe=1.5m

Length of Conduit after using Area of Pipe in Discharge Formula Elements

Variables
Length of Pipe
Length of Pipe describes the length of the pipe in which the liquid is flowing.
Symbol: Lpipe
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Material Coefficient
Material coefficient is defined as the constant depending on the property of material of dam.
Symbol: C1
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Head under Flow
Head under Flow is the combination of weir crested and additional head.
Symbol: Hf
Measurement: LengthUnit: m
Note: Value can be positive or negative.
Maximum Velocity
Maximum Velocity is the rate of change of its position with respect to a frame of reference, and is a function of time.
Symbol: Vmax
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.

Other formulas in Dams on Soft or Porous Foundations by Darcy’s law category

​Go Velocity given Length of Conduit after using Area of Pipe in Discharge
Vmax=C1HfLpipe
​Go Minimum Safe Length of Travel path under Dams on Soft or Porous Foundations
Ln=C2Hf
​Go New Material Coefficient C2 for Dams on Soft or Porous Foundations
C2=C1Vmax
​Go Maximum Velocity given New Material Coefficient C 2 for Dams on Soft Foundations
Vmax=C1C2

How to Evaluate Length of Conduit after using Area of Pipe in Discharge?

Length of Conduit after using Area of Pipe in Discharge evaluator uses Length of Pipe = Material Coefficient*Head under Flow/Maximum Velocity to evaluate the Length of Pipe, The Length of Conduit after using Area of Pipe in Discharge formula is defined as length of seepage pipes developed. Length of Pipe is denoted by Lpipe symbol.

How to evaluate Length of Conduit after using Area of Pipe in Discharge using this online evaluator? To use this online evaluator for Length of Conduit after using Area of Pipe in Discharge, enter Material Coefficient (C1), Head under Flow (Hf) & Maximum Velocity (Vmax) and hit the calculate button.

FAQs on Length of Conduit after using Area of Pipe in Discharge

What is the formula to find Length of Conduit after using Area of Pipe in Discharge?
The formula of Length of Conduit after using Area of Pipe in Discharge is expressed as Length of Pipe = Material Coefficient*Head under Flow/Maximum Velocity. Here is an example- 1.5 = 9*5/30.
How to calculate Length of Conduit after using Area of Pipe in Discharge?
With Material Coefficient (C1), Head under Flow (Hf) & Maximum Velocity (Vmax) we can find Length of Conduit after using Area of Pipe in Discharge using the formula - Length of Pipe = Material Coefficient*Head under Flow/Maximum Velocity.
Can the Length of Conduit after using Area of Pipe in Discharge be negative?
Yes, the Length of Conduit after using Area of Pipe in Discharge, measured in Length can be negative.
Which unit is used to measure Length of Conduit after using Area of Pipe in Discharge?
Length of Conduit after using Area of Pipe in Discharge is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length of Conduit after using Area of Pipe in Discharge can be measured.
Copied!