Length of 2nd Layer of Composite Wall in Conduction through Walls Formula

Fx Copy
LaTeX Copy
Length 2 is the length of the second body/object/section. Check FAQs
L2=k2Aw2(Ti2-To2Ql2-L1k1Aw2)
L2 - Length 2?k2 - Thermal Conductivity 2?Aw2 - Area of 2 Layer Wall?Ti2 - Inner Surface Temperature 2 layer wall?To2 - Outer Surface Temperature of 2 Layer?Ql2 - Heat Flow Rate 2 Layer?L1 - Length 1?k1 - Thermal Conductivity 1?

Length of 2nd Layer of Composite Wall in Conduction through Walls Example

With values
With units
Only example

Here is how the Length of 2nd Layer of Composite Wall in Conduction through Walls equation looks like with Values.

Here is how the Length of 2nd Layer of Composite Wall in Conduction through Walls equation looks like with Units.

Here is how the Length of 2nd Layer of Composite Wall in Conduction through Walls equation looks like.

5Edit=1.2Edit866.6667Edit(420.75Edit-420Edit120Edit-2Edit1.6Edit866.6667Edit)
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Heat and Mass Transfer » fx Length of 2nd Layer of Composite Wall in Conduction through Walls

Length of 2nd Layer of Composite Wall in Conduction through Walls Solution

Follow our step by step solution on how to calculate Length of 2nd Layer of Composite Wall in Conduction through Walls?

FIRST Step Consider the formula
L2=k2Aw2(Ti2-To2Ql2-L1k1Aw2)
Next Step Substitute values of Variables
L2=1.2W/(m*K)866.6667(420.75K-420K120W-2m1.6W/(m*K)866.6667)
Next Step Prepare to Evaluate
L2=1.2866.6667(420.75-420120-21.6866.6667)
Next Step Evaluate
L2=5.00000025m
LAST Step Rounding Answer
L2=5m

Length of 2nd Layer of Composite Wall in Conduction through Walls Formula Elements

Variables
Length 2
Length 2 is the length of the second body/object/section.
Symbol: L2
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Thermal Conductivity 2
Thermal Conductivity 2 is the thermal conductivity of the second body.
Symbol: k2
Measurement: Thermal ConductivityUnit: W/(m*K)
Note: Value should be greater than 0.
Area of 2 Layer Wall
Area of 2 layer Wall refers to the surface area of the wall, which is the total amount of space that it occupies. It is typically measured in square units such as square feet or square meters.
Symbol: Aw2
Measurement: AreaUnit:
Note: Value should be greater than 0.
Inner Surface Temperature 2 layer wall
Inner Surface Temperature 2 layer wall is the temperature at the inner surface of the wall (either plane wall or cylindrical wall or spherical wall, etc).
Symbol: Ti2
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Outer Surface Temperature of 2 Layer
Outer Surface Temperature of 2 layer is the temperature at the outer surface of the wall either plane wall or cylindrical wall or spherical wall, etc.
Symbol: To2
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Heat Flow Rate 2 Layer
Heat Flow Rate 2 layer is the amount of heat that is transferred per unit of time in some material, usually measured in watt. Heat is the flow of thermal energy driven by thermal non-equilibrium.
Symbol: Ql2
Measurement: PowerUnit: W
Note: Value can be positive or negative.
Length 1
Length 1 is the length of the first body.
Symbol: L1
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Thermal Conductivity 1
Thermal Conductivity 1 is the thermal conductivity of the first body.
Symbol: k1
Measurement: Thermal ConductivityUnit: W/(m*K)
Note: Value should be greater than 0.

Other formulas in 2 Layers category

​Go Thermal Resistance of Composite Wall with 2 Layers in Series
Rth2=L1k1Aw2+L2k2Aw2
​Go Outer Surface Temperature of Composite Wall of 2 Layers for Conduction
To2=Ti2-Ql2(L1k1Aw2+L2k2Aw2)

How to Evaluate Length of 2nd Layer of Composite Wall in Conduction through Walls?

Length of 2nd Layer of Composite Wall in Conduction through Walls evaluator uses Length 2 = Thermal Conductivity 2*Area of 2 Layer Wall*((Inner Surface Temperature 2 layer wall-Outer Surface Temperature of 2 Layer)/Heat Flow Rate 2 Layer-Length 1/(Thermal Conductivity 1*Area of 2 Layer Wall)) to evaluate the Length 2, The Length of 2nd layer of Composite Wall in Conduction through Walls formula is defined as the length/thickness of the second layer of the composite required to maintain a given temperature difference for a given heat flow rate, and length of the layer1, area, and thermal conductivities. Length 2 is denoted by L2 symbol.

How to evaluate Length of 2nd Layer of Composite Wall in Conduction through Walls using this online evaluator? To use this online evaluator for Length of 2nd Layer of Composite Wall in Conduction through Walls, enter Thermal Conductivity 2 (k2), Area of 2 Layer Wall (Aw2), Inner Surface Temperature 2 layer wall (Ti2), Outer Surface Temperature of 2 Layer (To2), Heat Flow Rate 2 Layer (Ql2), Length 1 (L1) & Thermal Conductivity 1 (k1) and hit the calculate button.

FAQs on Length of 2nd Layer of Composite Wall in Conduction through Walls

What is the formula to find Length of 2nd Layer of Composite Wall in Conduction through Walls?
The formula of Length of 2nd Layer of Composite Wall in Conduction through Walls is expressed as Length 2 = Thermal Conductivity 2*Area of 2 Layer Wall*((Inner Surface Temperature 2 layer wall-Outer Surface Temperature of 2 Layer)/Heat Flow Rate 2 Layer-Length 1/(Thermal Conductivity 1*Area of 2 Layer Wall)). Here is an example- 178.3333 = 1.2*866.6667*((420.75-420)/120-2/(1.6*866.6667)).
How to calculate Length of 2nd Layer of Composite Wall in Conduction through Walls?
With Thermal Conductivity 2 (k2), Area of 2 Layer Wall (Aw2), Inner Surface Temperature 2 layer wall (Ti2), Outer Surface Temperature of 2 Layer (To2), Heat Flow Rate 2 Layer (Ql2), Length 1 (L1) & Thermal Conductivity 1 (k1) we can find Length of 2nd Layer of Composite Wall in Conduction through Walls using the formula - Length 2 = Thermal Conductivity 2*Area of 2 Layer Wall*((Inner Surface Temperature 2 layer wall-Outer Surface Temperature of 2 Layer)/Heat Flow Rate 2 Layer-Length 1/(Thermal Conductivity 1*Area of 2 Layer Wall)).
Can the Length of 2nd Layer of Composite Wall in Conduction through Walls be negative?
No, the Length of 2nd Layer of Composite Wall in Conduction through Walls, measured in Length cannot be negative.
Which unit is used to measure Length of 2nd Layer of Composite Wall in Conduction through Walls?
Length of 2nd Layer of Composite Wall in Conduction through Walls is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length of 2nd Layer of Composite Wall in Conduction through Walls can be measured.
Copied!