Fx Copy
LaTeX Copy
Length of Pipe refers to the distance between two points along the pipe's axis. It is a fundamental parameter used to describe the size and layout of a piping system. Check FAQs
L=Δpt212μV
L - Length of Pipe?Δp - Pressure Difference in Viscous Flow?t - Thickness of Oil Film?μ - Viscosity of Fluid?V - Velocity of Fluid?

Length for Difference of Pressure in Viscous Flow between Two Parallel Plates Example

With values
With units
Only example

Here is how the Length for Difference of Pressure in Viscous Flow between Two Parallel Plates equation looks like with Values.

Here is how the Length for Difference of Pressure in Viscous Flow between Two Parallel Plates equation looks like with Units.

Here is how the Length for Difference of Pressure in Viscous Flow between Two Parallel Plates equation looks like.

3Edit=831.7133Edit4.6232Edit2128.23Edit60Edit
You are here -

Length for Difference of Pressure in Viscous Flow between Two Parallel Plates Solution

Follow our step by step solution on how to calculate Length for Difference of Pressure in Viscous Flow between Two Parallel Plates?

FIRST Step Consider the formula
L=Δpt212μV
Next Step Substitute values of Variables
L=831.7133N/m²4.6232m2128.23N*s/m²60m/s
Next Step Convert Units
L=831.7133Pa4.6232m2128.23Pa*s60m/s
Next Step Prepare to Evaluate
L=831.71334.62322128.2360
Next Step Evaluate
L=2.99999982390917m
LAST Step Rounding Answer
L=3m

Length for Difference of Pressure in Viscous Flow between Two Parallel Plates Formula Elements

Variables
Length of Pipe
Length of Pipe refers to the distance between two points along the pipe's axis. It is a fundamental parameter used to describe the size and layout of a piping system.
Symbol: L
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Pressure Difference in Viscous Flow
The Pressure Difference in Viscous Flow or the laminar flow is known to find the difference between initial and final pressure.
Symbol: Δp
Measurement: PressureUnit: N/m²
Note: Value can be positive or negative.
Thickness of Oil Film
Thickness of Oil Film refers to the distance or dimension between the surfaces that are separated by a layer of oil.
Symbol: t
Measurement: LengthUnit: m
Note: Value should be greater than 0.
Viscosity of Fluid
The Viscosity of fluid is a measure of its resistance to deformation at a given rate.
Symbol: μ
Measurement: Dynamic ViscosityUnit: N*s/m²
Note: Value can be positive or negative.
Velocity of Fluid
Velocity of Fluid refers to the speed at which the fluid particles are moving in a particular direction.
Symbol: V
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.

Other Formulas to find Length of Pipe

​Go Length for Pressure Head Loss in Viscous Flow between Two Parallel Plates
L=ρ[g]hft212μV
​Go Length of Pipe for Difference of Pressure in Viscous Flow
L=ΔpDp232μova
​Go Length of Pipe for Loss of Pressure Head in Viscous Flow
L=hfρ[g]Dp232μV
​Go Length of Pipe for Head Loss due to Friction in Viscous Flow
L=hLDp2[g]4μfva2

Other formulas in Dimensions and Geometry category

​Go Diameter of Pipe from Maximum Velocity and Velocity at Any Radius
do=2r1-VVm
​Go Diameter of Shaft for Torque Required in Foot-Step Bearing
Ds=2(τtπ2μN)14
​Go External or Outer Radius of Collar for Total Torque
R1=(R24+τtπ2μN)14
​Go Internal or Inner Radius of Collar for Total Torque
R2=(R14+τtπ2μN)14

How to Evaluate Length for Difference of Pressure in Viscous Flow between Two Parallel Plates?

Length for Difference of Pressure in Viscous Flow between Two Parallel Plates evaluator uses Length of Pipe = (Pressure Difference in Viscous Flow*Thickness of Oil Film^2)/(12*Viscosity of Fluid*Velocity of Fluid) to evaluate the Length of Pipe, Length for Difference of Pressure in Viscous Flow between Two Parallel Plates can be determined using a formula that relates it to the viscosity of the fluid, the distance between the plates, and the shear stress exerted by the fluid. This calculation helps in understanding how pressure varies along the length between the plates due to viscous effects. Length of Pipe is denoted by L symbol.

How to evaluate Length for Difference of Pressure in Viscous Flow between Two Parallel Plates using this online evaluator? To use this online evaluator for Length for Difference of Pressure in Viscous Flow between Two Parallel Plates, enter Pressure Difference in Viscous Flow (Δp), Thickness of Oil Film (t), Viscosity of Fluid (μ) & Velocity of Fluid (V) and hit the calculate button.

FAQs on Length for Difference of Pressure in Viscous Flow between Two Parallel Plates

What is the formula to find Length for Difference of Pressure in Viscous Flow between Two Parallel Plates?
The formula of Length for Difference of Pressure in Viscous Flow between Two Parallel Plates is expressed as Length of Pipe = (Pressure Difference in Viscous Flow*Thickness of Oil Film^2)/(12*Viscosity of Fluid*Velocity of Fluid). Here is an example- 44.52856 = (831.7133*4.623171^2)/(12*8.23*60).
How to calculate Length for Difference of Pressure in Viscous Flow between Two Parallel Plates?
With Pressure Difference in Viscous Flow (Δp), Thickness of Oil Film (t), Viscosity of Fluid (μ) & Velocity of Fluid (V) we can find Length for Difference of Pressure in Viscous Flow between Two Parallel Plates using the formula - Length of Pipe = (Pressure Difference in Viscous Flow*Thickness of Oil Film^2)/(12*Viscosity of Fluid*Velocity of Fluid).
What are the other ways to Calculate Length of Pipe?
Here are the different ways to Calculate Length of Pipe-
  • Length of Pipe=(Density of Liquid*[g]*Loss of Peizometric Head*Thickness of Oil Film^2)/(12*Viscosity of Fluid*Velocity of Fluid)OpenImg
  • Length of Pipe=(Pressure Difference in Viscous Flow*Diameter of Pipe^2)/(32*Viscosity of Oil*Average Velocity)OpenImg
  • Length of Pipe=(Loss of Peizometric Head*Density of Liquid*[g]*Diameter of Pipe^2)/(32*Viscosity of Fluid*Velocity of Fluid)OpenImg
Can the Length for Difference of Pressure in Viscous Flow between Two Parallel Plates be negative?
No, the Length for Difference of Pressure in Viscous Flow between Two Parallel Plates, measured in Length cannot be negative.
Which unit is used to measure Length for Difference of Pressure in Viscous Flow between Two Parallel Plates?
Length for Difference of Pressure in Viscous Flow between Two Parallel Plates is usually measured using the Meter[m] for Length. Millimeter[m], Kilometer[m], Decimeter[m] are the few other units in which Length for Difference of Pressure in Viscous Flow between Two Parallel Plates can be measured.
Copied!