Collector Base Leakage Current is a current that flows in a bipolar junction transistor (BJT) between the collector and base terminals when the transistor is in its reverse-biased condition. Check FAQs
ICBO=IC-αIC
ICBO - Collector Base Leakage Current?IC - Collector Current?α - Common-Base Current Gain?

Leakage Current of Collector-Base Junction Example

With values
With units
Only example

Here is how the Leakage Current of Collector-Base Junction equation looks like with Values.

Here is how the Leakage Current of Collector-Base Junction equation looks like with Units.

Here is how the Leakage Current of Collector-Base Junction equation looks like.

30Edit=100Edit-0.7Edit100Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Leakage Current of Collector-Base Junction

Leakage Current of Collector-Base Junction Solution

Follow our step by step solution on how to calculate Leakage Current of Collector-Base Junction?

FIRST Step Consider the formula
ICBO=IC-αIC
Next Step Substitute values of Variables
ICBO=100A-0.7100A
Next Step Prepare to Evaluate
ICBO=100-0.7100
LAST Step Evaluate
ICBO=30A

Leakage Current of Collector-Base Junction Formula Elements

Variables
Collector Base Leakage Current
Collector Base Leakage Current is a current that flows in a bipolar junction transistor (BJT) between the collector and base terminals when the transistor is in its reverse-biased condition.
Symbol: ICBO
Measurement: Electric CurrentUnit: A
Note: Value should be greater than 0.
Collector Current
Collector Current refers to the current that flows between the collector and emitter terminals when the SCR is in its conducting or ON state.
Symbol: IC
Measurement: Electric CurrentUnit: A
Note: Value should be greater than 0.
Common-Base Current Gain
Common-Base Current Gain is defined as the change in collector current divided by the change in emitter current when the base-to-collector voltage is constant.
Symbol: α
Measurement: NAUnit: Unitless
Note: Value should be less than 1.

Other formulas in SCR Performance Parameters category

​Go Derating Factor of Series Connected Thyristor String
DRF=1-VstringVssn
​Go Power Dissipated by Heat in SCR
Pdis=Tjunc-Tambθ
​Go Thermal Resistance of SCR
θ=Tjunc-TambPdis
​Go Worst Case Steady State Voltage across First Thyristor in Series Connected Thyristors
Vss=Vstring+Rstb(n-1)ΔIDn

How to Evaluate Leakage Current of Collector-Base Junction?

Leakage Current of Collector-Base Junction evaluator uses Collector Base Leakage Current = Collector Current-Common-Base Current Gain*Collector Current to evaluate the Collector Base Leakage Current, The Leakage Current of Collector-Base Junction is the difference between the collector current and the common base current gain of the transistor (α) times the emitter current. α is the ratio of IC to IE . Collector Base Leakage Current is denoted by ICBO symbol.

How to evaluate Leakage Current of Collector-Base Junction using this online evaluator? To use this online evaluator for Leakage Current of Collector-Base Junction, enter Collector Current (IC) & Common-Base Current Gain (α) and hit the calculate button.

FAQs on Leakage Current of Collector-Base Junction

What is the formula to find Leakage Current of Collector-Base Junction?
The formula of Leakage Current of Collector-Base Junction is expressed as Collector Base Leakage Current = Collector Current-Common-Base Current Gain*Collector Current. Here is an example- 30 = 100-0.7*100.
How to calculate Leakage Current of Collector-Base Junction?
With Collector Current (IC) & Common-Base Current Gain (α) we can find Leakage Current of Collector-Base Junction using the formula - Collector Base Leakage Current = Collector Current-Common-Base Current Gain*Collector Current.
Can the Leakage Current of Collector-Base Junction be negative?
No, the Leakage Current of Collector-Base Junction, measured in Electric Current cannot be negative.
Which unit is used to measure Leakage Current of Collector-Base Junction?
Leakage Current of Collector-Base Junction is usually measured using the Ampere[A] for Electric Current. Milliampere[A], Microampere[A], Centiampere[A] are the few other units in which Leakage Current of Collector-Base Junction can be measured.