Key Reactant Concentration with Varying Density,Temperature and Total Pressure Formula

Fx Copy
LaTeX Copy
Key-Reactant Concentration is the concentration of the reactant which is considered as a basis for determining conversion. Check FAQs
Ckey=Ckey0(1-Xkey1+εXkey)(T0πTCREπ0)
Ckey - Key-Reactant Concentration?Ckey0 - Initial Key-Reactant Concentration?Xkey - Key-Reactant Conversion?ε - Fractional Volume Change?T0 - Initial Temperature?π - Total Pressure?TCRE - Temperature?π0 - Initial Total Pressure?

Key Reactant Concentration with Varying Density,Temperature and Total Pressure Example

With values
With units
Only example

Here is how the Key Reactant Concentration with Varying Density,Temperature and Total Pressure equation looks like with Values.

Here is how the Key Reactant Concentration with Varying Density,Temperature and Total Pressure equation looks like with Units.

Here is how the Key Reactant Concentration with Varying Density,Temperature and Total Pressure equation looks like.

34Edit=13.0357Edit(1-0.3Edit1+0.21Edit0.3Edit)(303Edit50Edit85Edit45Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Chemical Reaction Engineering » fx Key Reactant Concentration with Varying Density,Temperature and Total Pressure

Key Reactant Concentration with Varying Density,Temperature and Total Pressure Solution

Follow our step by step solution on how to calculate Key Reactant Concentration with Varying Density,Temperature and Total Pressure?

FIRST Step Consider the formula
Ckey=Ckey0(1-Xkey1+εXkey)(T0πTCREπ0)
Next Step Substitute values of Variables
Ckey=13.0357mol/m³(1-0.31+0.210.3)(303K50Pa85K45Pa)
Next Step Prepare to Evaluate
Ckey=13.0357(1-0.31+0.210.3)(303508545)
Next Step Evaluate
Ckey=34.0000059764263mol/m³
LAST Step Rounding Answer
Ckey=34mol/m³

Key Reactant Concentration with Varying Density,Temperature and Total Pressure Formula Elements

Variables
Key-Reactant Concentration
Key-Reactant Concentration is the concentration of the reactant which is considered as a basis for determining conversion.
Symbol: Ckey
Measurement: Molar ConcentrationUnit: mol/m³
Note: Value should be greater than 0.
Initial Key-Reactant Concentration
Initial Key-Reactant Concentration is the concentration of the reactant which is considered as a basis for determining conversion.
Symbol: Ckey0
Measurement: Molar ConcentrationUnit: mol/m³
Note: Value can be positive or negative.
Key-Reactant Conversion
Key-Reactant Conversion gives us the percentage of reactant converted into product whose quantity play a significant role in the chemical reaction.
Symbol: Xkey
Measurement: NAUnit: Unitless
Note: Value should be less than 1.
Fractional Volume Change
Fractional Volume Change is the ratio of the change in volume and the initial volume.
Symbol: ε
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Initial Temperature
Initial Temperature is the varying temperature of the system just before the process under consideration.
Symbol: T0
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Total Pressure
Total Pressure is the total force that the gas exerts on the walls of its container at given time during a chemical reaction.
Symbol: π
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.
Temperature
Temperature is the degree or intensity of heat present in a substance or object.
Symbol: TCRE
Measurement: TemperatureUnit: K
Note: Value can be positive or negative.
Initial Total Pressure
Initial Total Pressure is the total force that the gas exerts on the walls of its container before chemical reaction.
Symbol: π0
Measurement: PressureUnit: Pa
Note: Value can be positive or negative.

Other formulas in Introduction to Reactor Design category

​Go Initial Key Reactant Concentration with Varying Density,Temperature and Total Pressure
Ckey0=Ckey(1+εXkey1-Xkey)(TCREπ0T0π)
​Go Initial Reactant Concentration using Reactant Conversion
Co=C1-XA

How to Evaluate Key Reactant Concentration with Varying Density,Temperature and Total Pressure?

Key Reactant Concentration with Varying Density,Temperature and Total Pressure evaluator uses Key-Reactant Concentration = Initial Key-Reactant Concentration*((1-Key-Reactant Conversion)/(1+Fractional Volume Change*Key-Reactant Conversion))*((Initial Temperature*Total Pressure)/(Temperature*Initial Total Pressure)) to evaluate the Key-Reactant Concentration, The Key Reactant Concentration with Varying Density,Temperature and Total Pressure formula is defined as the concentration of the reactant whose quantity play a significant role in the chemical reaction while density, temperature and total pressure of system are varying. Key-Reactant Concentration is denoted by Ckey symbol.

How to evaluate Key Reactant Concentration with Varying Density,Temperature and Total Pressure using this online evaluator? To use this online evaluator for Key Reactant Concentration with Varying Density,Temperature and Total Pressure, enter Initial Key-Reactant Concentration (Ckey0), Key-Reactant Conversion (Xkey), Fractional Volume Change (ε), Initial Temperature (T0), Total Pressure (π), Temperature (TCRE) & Initial Total Pressure 0) and hit the calculate button.

FAQs on Key Reactant Concentration with Varying Density,Temperature and Total Pressure

What is the formula to find Key Reactant Concentration with Varying Density,Temperature and Total Pressure?
The formula of Key Reactant Concentration with Varying Density,Temperature and Total Pressure is expressed as Key-Reactant Concentration = Initial Key-Reactant Concentration*((1-Key-Reactant Conversion)/(1+Fractional Volume Change*Key-Reactant Conversion))*((Initial Temperature*Total Pressure)/(Temperature*Initial Total Pressure)). Here is an example- 234.7407 = 13.03566*((1-0.3)/(1+0.21*0.3))*((303*50)/(85*45)).
How to calculate Key Reactant Concentration with Varying Density,Temperature and Total Pressure?
With Initial Key-Reactant Concentration (Ckey0), Key-Reactant Conversion (Xkey), Fractional Volume Change (ε), Initial Temperature (T0), Total Pressure (π), Temperature (TCRE) & Initial Total Pressure 0) we can find Key Reactant Concentration with Varying Density,Temperature and Total Pressure using the formula - Key-Reactant Concentration = Initial Key-Reactant Concentration*((1-Key-Reactant Conversion)/(1+Fractional Volume Change*Key-Reactant Conversion))*((Initial Temperature*Total Pressure)/(Temperature*Initial Total Pressure)).
Can the Key Reactant Concentration with Varying Density,Temperature and Total Pressure be negative?
No, the Key Reactant Concentration with Varying Density,Temperature and Total Pressure, measured in Molar Concentration cannot be negative.
Which unit is used to measure Key Reactant Concentration with Varying Density,Temperature and Total Pressure?
Key Reactant Concentration with Varying Density,Temperature and Total Pressure is usually measured using the Mole per Cubic Meter[mol/m³] for Molar Concentration. Mole per Liter[mol/m³], Mole per Cubic Millimeter[mol/m³], Kilomole per Cubic Meter[mol/m³] are the few other units in which Key Reactant Concentration with Varying Density,Temperature and Total Pressure can be measured.
Copied!