Intensity of Precipitation when Peak Discharge for Field Application is Considered Formula

Fx Copy
LaTeX Copy
Mean Intensity of Precipitation (mm/hr) for a duration equal to tc and an exceedance probability P. Check FAQs
itcp=Qp(13.6)CrAD
itcp - Mean Intensity of Precipitation?Qp - Peak Discharge?Cr - Runoff Coefficient?AD - Drainage Area?

Intensity of Precipitation when Peak Discharge for Field Application is Considered Example

With values
With units
Only example

Here is how the Intensity of Precipitation when Peak Discharge for Field Application is Considered equation looks like with Values.

Here is how the Intensity of Precipitation when Peak Discharge for Field Application is Considered equation looks like with Units.

Here is how the Intensity of Precipitation when Peak Discharge for Field Application is Considered equation looks like.

5.76Edit=4Edit(13.6)0.5Edit18Edit
You are here -

Intensity of Precipitation when Peak Discharge for Field Application is Considered Solution

Follow our step by step solution on how to calculate Intensity of Precipitation when Peak Discharge for Field Application is Considered?

FIRST Step Consider the formula
itcp=Qp(13.6)CrAD
Next Step Substitute values of Variables
itcp=4m³/s(13.6)0.518km²
Next Step Convert Units
itcp=4m³/s(13.6)0.51.8E+7
Next Step Prepare to Evaluate
itcp=4(13.6)0.51.8E+7
Next Step Evaluate
itcp=1.6E-06m/s
LAST Step Convert to Output's Unit
itcp=5.76mm/h

Intensity of Precipitation when Peak Discharge for Field Application is Considered Formula Elements

Variables
Mean Intensity of Precipitation
Mean Intensity of Precipitation (mm/hr) for a duration equal to tc and an exceedance probability P.
Symbol: itcp
Measurement: SpeedUnit: mm/h
Note: Value should be greater than 0.
Peak Discharge
Peak Discharge is the maximum volume flow rate passing a particular location during an event.
Symbol: Qp
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Runoff Coefficient
Runoff Coefficient is a dimensionless coefficient relating the amount of runoff to the amount of precipitation received.
Symbol: Cr
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Drainage Area
Drainage Area is the total surface area, where the water from rain which is not absorbed into the ground flows over the ground surface, back into streams, to finally reach that point.
Symbol: AD
Measurement: AreaUnit: km²
Note: Value can be positive or negative.

Other formulas in Rational Method to Estimate the Flood Peak category

​Go Value of Peak Discharge
Qp=CrADi
​Go Coefficient of Runoff when Peak Value is Considered
Cr=QpADi
​Go Drainage Area when Peak Discharge is Considered
AD=QpiCr
​Go Intensity of Rainfall when Peak Discharge is Considered
i=QpCrAD

How to Evaluate Intensity of Precipitation when Peak Discharge for Field Application is Considered?

Intensity of Precipitation when Peak Discharge for Field Application is Considered evaluator uses Mean Intensity of Precipitation = Peak Discharge/((1/3.6)*Runoff Coefficient*Drainage Area) to evaluate the Mean Intensity of Precipitation, The Intensity of Precipitation when Peak Discharge for Field Application is Considered Rainfall formula is defined as the ratio of the total amount of rain (rainfall depth) falling during a given period to the duration of the period. Mean Intensity of Precipitation is denoted by itcp symbol.

How to evaluate Intensity of Precipitation when Peak Discharge for Field Application is Considered using this online evaluator? To use this online evaluator for Intensity of Precipitation when Peak Discharge for Field Application is Considered, enter Peak Discharge (Qp), Runoff Coefficient (Cr) & Drainage Area (AD) and hit the calculate button.

FAQs on Intensity of Precipitation when Peak Discharge for Field Application is Considered

What is the formula to find Intensity of Precipitation when Peak Discharge for Field Application is Considered?
The formula of Intensity of Precipitation when Peak Discharge for Field Application is Considered is expressed as Mean Intensity of Precipitation = Peak Discharge/((1/3.6)*Runoff Coefficient*Drainage Area). Here is an example- 2.1E+7 = 4/((1/3.6)*0.5*18000000).
How to calculate Intensity of Precipitation when Peak Discharge for Field Application is Considered?
With Peak Discharge (Qp), Runoff Coefficient (Cr) & Drainage Area (AD) we can find Intensity of Precipitation when Peak Discharge for Field Application is Considered using the formula - Mean Intensity of Precipitation = Peak Discharge/((1/3.6)*Runoff Coefficient*Drainage Area).
Can the Intensity of Precipitation when Peak Discharge for Field Application is Considered be negative?
No, the Intensity of Precipitation when Peak Discharge for Field Application is Considered, measured in Speed cannot be negative.
Which unit is used to measure Intensity of Precipitation when Peak Discharge for Field Application is Considered?
Intensity of Precipitation when Peak Discharge for Field Application is Considered is usually measured using the Millimeter per Hour[mm/h] for Speed. Meter per Second[mm/h], Meter per Minute[mm/h], Meter per Hour[mm/h] are the few other units in which Intensity of Precipitation when Peak Discharge for Field Application is Considered can be measured.
Copied!