Fx Copy
LaTeX Copy
Drain current is the current that flows between the drain and the source terminals of a field-effect transistor (FET), which is a type of transistor commonly used in electronic circuits. Check FAQs
id=Kn((Vc-Vt)2)
id - Drain Current?Kn - Transconductance Parameter?Vc - Critical Voltage?Vt - Total Voltage?

Instantaneous Drain Current with respect to DC Component of Vgs Example

With values
With units
Only example

Here is how the Instantaneous Drain Current with respect to DC Component of Vgs equation looks like with Values.

Here is how the Instantaneous Drain Current with respect to DC Component of Vgs equation looks like with Units.

Here is how the Instantaneous Drain Current with respect to DC Component of Vgs equation looks like.

206.1259Edit=0.07Edit((0.284Edit-2Edit)2)
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Analog Electronics » fx Instantaneous Drain Current with respect to DC Component of Vgs

Instantaneous Drain Current with respect to DC Component of Vgs Solution

Follow our step by step solution on how to calculate Instantaneous Drain Current with respect to DC Component of Vgs?

FIRST Step Consider the formula
id=Kn((Vc-Vt)2)
Next Step Substitute values of Variables
id=0.07A/V²((0.284V-2V)2)
Next Step Prepare to Evaluate
id=0.07((0.284-2)2)
Next Step Evaluate
id=0.20612592A
Next Step Convert to Output's Unit
id=206.12592mA
LAST Step Rounding Answer
id=206.1259mA

Instantaneous Drain Current with respect to DC Component of Vgs Formula Elements

Variables
Drain Current
Drain current is the current that flows between the drain and the source terminals of a field-effect transistor (FET), which is a type of transistor commonly used in electronic circuits.
Symbol: id
Measurement: Electric CurrentUnit: mA
Note: Value should be greater than 0.
Transconductance Parameter
Transconductance parameter Kn is a measure of the change in current flowing through a transistor in response to a small change in voltage.
Symbol: Kn
Measurement: Transconductance ParameterUnit: A/V²
Note: Value should be greater than 0.
Critical Voltage
Critical Voltage is the minimum phase to the neutral voltage which glows and appears all along the line conductor.
Symbol: Vc
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Total Voltage
The total voltage in a series circuit is equal to the sum of all the individual voltage drops in the circuit.
Symbol: Vt
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other Formulas to find Drain Current

​Go Drain Current of MOSFET on Large-Signal Operation given Overdrive Voltage
id=(IbVov)(Vid2)
​Go Drain Current without Channel-Length Modulation of MOSFET
id=12k'pWL(Vgs-Vth)2
​Go Drain Current in Load Line
id=Vdd-VdsRL
​Go Instantaneous Drain Current
id=Kn(Vgsq-Vt+Vc)2

Other formulas in Current category

​Go First Drain Current of MOSFET on Large-Signal Operation
Id1=Ib2+IbVovVid21-Vid24Vov2
​Go Second Drain Current of MOSFET on Large-Signal Operation
Id2=Ib2-IbVovVid21-(Vid)24Vov2
​Go First Drain Current of MOSFET on Large-Signal Operation given Overdrive Voltage
Id1=Ib2+IbVovVid2
​Go Second Drain Current of MOSFET on Large-Signal Operation given Overdrive Voltage
Id2=Ib2-IbVovVid2

How to Evaluate Instantaneous Drain Current with respect to DC Component of Vgs?

Instantaneous Drain Current with respect to DC Component of Vgs evaluator uses Drain Current = Transconductance Parameter*((Critical Voltage-Total Voltage)^2) to evaluate the Drain Current, The Instantaneous Drain Current with respect to DC Component of Vgs is defined as the drain current which is passed through the transistor when a gate to source voltage is acting on it. Drain Current is denoted by id symbol.

How to evaluate Instantaneous Drain Current with respect to DC Component of Vgs using this online evaluator? To use this online evaluator for Instantaneous Drain Current with respect to DC Component of Vgs, enter Transconductance Parameter (Kn), Critical Voltage (Vc) & Total Voltage (Vt) and hit the calculate button.

FAQs on Instantaneous Drain Current with respect to DC Component of Vgs

What is the formula to find Instantaneous Drain Current with respect to DC Component of Vgs?
The formula of Instantaneous Drain Current with respect to DC Component of Vgs is expressed as Drain Current = Transconductance Parameter*((Critical Voltage-Total Voltage)^2). Here is an example- 45587.43 = 0.07*((0.284-2)^2).
How to calculate Instantaneous Drain Current with respect to DC Component of Vgs?
With Transconductance Parameter (Kn), Critical Voltage (Vc) & Total Voltage (Vt) we can find Instantaneous Drain Current with respect to DC Component of Vgs using the formula - Drain Current = Transconductance Parameter*((Critical Voltage-Total Voltage)^2).
What are the other ways to Calculate Drain Current?
Here are the different ways to Calculate Drain Current-
  • Drain Current=(DC Bias Current/Overdrive Voltage)*(Differential Input Signal/2)OpenImg
  • Drain Current=1/2*Process Transconductance in PMOS*Aspect Ratio*(Gate-Source Voltage-Threshold Voltage)^2OpenImg
  • Drain Current=(Supply Voltage-Drain Source Voltage)/Load ResistanceOpenImg
Can the Instantaneous Drain Current with respect to DC Component of Vgs be negative?
No, the Instantaneous Drain Current with respect to DC Component of Vgs, measured in Electric Current cannot be negative.
Which unit is used to measure Instantaneous Drain Current with respect to DC Component of Vgs?
Instantaneous Drain Current with respect to DC Component of Vgs is usually measured using the Milliampere[mA] for Electric Current. Ampere[mA], Microampere[mA], Centiampere[mA] are the few other units in which Instantaneous Drain Current with respect to DC Component of Vgs can be measured.
Copied!