Inside Area given Thermal Resistance for Inner Surface Formula

Fx Copy
LaTeX Copy
Inside Area is defined as the space inside the shape. It's a measure of 2-D space, and the units for area are squared ("length squared"). Check FAQs
Ainside=1hinsideRth
Ainside - Inside Area?hinside - Inside Convection Heat Transfer Coefficient?Rth - Thermal Resistance?

Inside Area given Thermal Resistance for Inner Surface Example

With values
With units
Only example

Here is how the Inside Area given Thermal Resistance for Inner Surface equation looks like with Values.

Here is how the Inside Area given Thermal Resistance for Inner Surface equation looks like with Units.

Here is how the Inside Area given Thermal Resistance for Inner Surface equation looks like.

0.1425Edit=11.35Edit5.2Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Heat Transfer » fx Inside Area given Thermal Resistance for Inner Surface

Inside Area given Thermal Resistance for Inner Surface Solution

Follow our step by step solution on how to calculate Inside Area given Thermal Resistance for Inner Surface?

FIRST Step Consider the formula
Ainside=1hinsideRth
Next Step Substitute values of Variables
Ainside=11.35W/m²*K5.2K/W
Next Step Prepare to Evaluate
Ainside=11.355.2
Next Step Evaluate
Ainside=0.142450142450142
LAST Step Rounding Answer
Ainside=0.1425

Inside Area given Thermal Resistance for Inner Surface Formula Elements

Variables
Inside Area
Inside Area is defined as the space inside the shape. It's a measure of 2-D space, and the units for area are squared ("length squared").
Symbol: Ainside
Measurement: AreaUnit:
Note: Value should be greater than 0.
Inside Convection Heat Transfer Coefficient
Inside Convection Heat Transfer Coefficient is the coefficient of convection heat transfer at the inside surface of the body or object or wall, etc.
Symbol: hinside
Measurement: Heat Transfer CoefficientUnit: W/m²*K
Note: Value should be greater than 0.
Thermal Resistance
Thermal resistance is a heat property and a measurement of a temperature difference by which an object or material resists a heat flow.
Symbol: Rth
Measurement: Thermal ResistanceUnit: K/W
Note: Value can be positive or negative.

Other formulas in Thermal Resistance category

​Go Biot Number using Characteristic Length
Bi=htransferLcharkfin
​Go Correction Length for Cylindrical Fin with Non-Adiabatic Tip
Lcylindrical=Lfin+(dfin4)
​Go Correction Length for Square Fin with Non-Adiabatic Tip
Lsqaure=Lfin+(wfin4)
​Go Correction Length for Thin Rectangular Fin with Non-Adiabatic Tip
Lrectangular=Lfin+(tfin2)

How to Evaluate Inside Area given Thermal Resistance for Inner Surface?

Inside Area given Thermal Resistance for Inner Surface evaluator uses Inside Area = 1/(Inside Convection Heat Transfer Coefficient*Thermal Resistance) to evaluate the Inside Area, The Inside Area given Thermal Resistance for Inner Surface formula is defined as as the reciprocal of multiplication of Thermal resistance and inside Heat Transfer coefficient. The convective heat transfer coefficient depends on the fluid’s physical properties and the physical situation. The convective heat transfer coefficient is not a property of the fluid. It is an experimentally determined parameter whose value depends on all the variables influencing convection, such as the surface geometry, the nature of fluid motion, the properties of the fluid, and the bulk fluid velocity. Inside Area is denoted by Ainside symbol.

How to evaluate Inside Area given Thermal Resistance for Inner Surface using this online evaluator? To use this online evaluator for Inside Area given Thermal Resistance for Inner Surface, enter Inside Convection Heat Transfer Coefficient (hinside) & Thermal Resistance (Rth) and hit the calculate button.

FAQs on Inside Area given Thermal Resistance for Inner Surface

What is the formula to find Inside Area given Thermal Resistance for Inner Surface?
The formula of Inside Area given Thermal Resistance for Inner Surface is expressed as Inside Area = 1/(Inside Convection Heat Transfer Coefficient*Thermal Resistance). Here is an example- 0.14245 = 1/(1.35*5.2).
How to calculate Inside Area given Thermal Resistance for Inner Surface?
With Inside Convection Heat Transfer Coefficient (hinside) & Thermal Resistance (Rth) we can find Inside Area given Thermal Resistance for Inner Surface using the formula - Inside Area = 1/(Inside Convection Heat Transfer Coefficient*Thermal Resistance).
Can the Inside Area given Thermal Resistance for Inner Surface be negative?
No, the Inside Area given Thermal Resistance for Inner Surface, measured in Area cannot be negative.
Which unit is used to measure Inside Area given Thermal Resistance for Inner Surface?
Inside Area given Thermal Resistance for Inner Surface is usually measured using the Square Meter[m²] for Area. Square Kilometer[m²], Square Centimeter[m²], Square Millimeter[m²] are the few other units in which Inside Area given Thermal Resistance for Inner Surface can be measured.
Copied!