Input Voltage of Non-Inverting Schmitt Trigger Formula

Fx Copy
LaTeX Copy
The Non-Inverting Input Voltage of an operational amplifier (op amp) is the voltage that is applied to the pin marked with a plus (+) sign. Check FAQs
V+=(R1R1+R2)Vo
V+ - Non-Inverting Input Voltage?R1 - Resistance 1?R2 - Resistance 2?Vo - Output Voltage?

Input Voltage of Non-Inverting Schmitt Trigger Example

With values
With units
Only example

Here is how the Input Voltage of Non-Inverting Schmitt Trigger equation looks like with Values.

Here is how the Input Voltage of Non-Inverting Schmitt Trigger equation looks like with Units.

Here is how the Input Voltage of Non-Inverting Schmitt Trigger equation looks like.

0.9737Edit=(10Edit10Edit+5.2Edit)1.48Edit
You are here -
HomeIcon Home » Category Engineering » Category Electronics » Category Integrated Circuits (IC) » fx Input Voltage of Non-Inverting Schmitt Trigger

Input Voltage of Non-Inverting Schmitt Trigger Solution

Follow our step by step solution on how to calculate Input Voltage of Non-Inverting Schmitt Trigger?

FIRST Step Consider the formula
V+=(R1R1+R2)Vo
Next Step Substitute values of Variables
V+=(1010+5.2)1.48V
Next Step Convert Units
V+=(10000Ω10000Ω+5200Ω)1.48V
Next Step Prepare to Evaluate
V+=(1000010000+5200)1.48
Next Step Evaluate
V+=0.973684210526316V
LAST Step Rounding Answer
V+=0.9737V

Input Voltage of Non-Inverting Schmitt Trigger Formula Elements

Variables
Non-Inverting Input Voltage
The Non-Inverting Input Voltage of an operational amplifier (op amp) is the voltage that is applied to the pin marked with a plus (+) sign.
Symbol: V+
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.
Resistance 1
Resistance 1 is a measure of the opposition to the flow of electric current through a material.
Symbol: R1
Measurement: Electric ResistanceUnit:
Note: Value should be greater than 0.
Resistance 2
Resistance 2 is a measure of the opposition to the flow of electric current through a material.
Symbol: R2
Measurement: Electric ResistanceUnit:
Note: Value should be greater than 0.
Output Voltage
Output voltage is the voltage that is produced by a device, such as a power supply, a battery, or a generator. It is measured in volts (V).
Symbol: Vo
Measurement: Electric PotentialUnit: V
Note: Value should be greater than 0.

Other formulas in Schmitt Trigger category

​Go Input Current of Schmitt Trigger
in=VinRin
​Go Lower Threshold Voltage of Inverting Schmitt Trigger
Vf=-Vsat(R2R1+R2)
​Go Open Loop Gain of Schmitt Trigger
Av=VfiV+-V-
​Go Lower Threshold Voltage of Non Inverting Schmitt Trigger
Vlt=-Vsat(R2R1)

How to Evaluate Input Voltage of Non-Inverting Schmitt Trigger?

Input Voltage of Non-Inverting Schmitt Trigger evaluator uses Non-Inverting Input Voltage = (Resistance 1/(Resistance 1+Resistance 2))*Output Voltage to evaluate the Non-Inverting Input Voltage, The Input Voltage of Non-Inverting Schmitt Trigger formula can be adjusted by changing the values of the feedback resistor R1 and the input resistor R2. The upper threshold voltage is increased when the feedback resistor R2 is increased and the input resistor R1 is decreased. Non-Inverting Input Voltage is denoted by V+ symbol.

How to evaluate Input Voltage of Non-Inverting Schmitt Trigger using this online evaluator? To use this online evaluator for Input Voltage of Non-Inverting Schmitt Trigger, enter Resistance 1 (R1), Resistance 2 (R2) & Output Voltage (Vo) and hit the calculate button.

FAQs on Input Voltage of Non-Inverting Schmitt Trigger

What is the formula to find Input Voltage of Non-Inverting Schmitt Trigger?
The formula of Input Voltage of Non-Inverting Schmitt Trigger is expressed as Non-Inverting Input Voltage = (Resistance 1/(Resistance 1+Resistance 2))*Output Voltage. Here is an example- 0.973684 = (10000/(10000+5200))*1.48.
How to calculate Input Voltage of Non-Inverting Schmitt Trigger?
With Resistance 1 (R1), Resistance 2 (R2) & Output Voltage (Vo) we can find Input Voltage of Non-Inverting Schmitt Trigger using the formula - Non-Inverting Input Voltage = (Resistance 1/(Resistance 1+Resistance 2))*Output Voltage.
Can the Input Voltage of Non-Inverting Schmitt Trigger be negative?
No, the Input Voltage of Non-Inverting Schmitt Trigger, measured in Electric Potential cannot be negative.
Which unit is used to measure Input Voltage of Non-Inverting Schmitt Trigger?
Input Voltage of Non-Inverting Schmitt Trigger is usually measured using the Volt[V] for Electric Potential. Millivolt[V], Microvolt[V], Nanovolt[V] are the few other units in which Input Voltage of Non-Inverting Schmitt Trigger can be measured.
Copied!