Input Power of Single Phase Full Converter Drives Formula

Fx Copy
LaTeX Copy
Input Power of single-phase full converter drive is an electronic control system used to regulate the speed and direction of single-phase alternating current (AC) motors. Check FAQs
Pin=(22π)cos(α)
Pin - Input Power?α - Delay Angle of Thyristor?π - Archimedes' constant?

Input Power of Single Phase Full Converter Drives Example

With values
With units
Only example

Here is how the Input Power of Single Phase Full Converter Drives equation looks like with Values.

Here is how the Input Power of Single Phase Full Converter Drives equation looks like with Units.

Here is how the Input Power of Single Phase Full Converter Drives equation looks like.

0.3079Edit=(223.1416)cos(70Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power Electronics » fx Input Power of Single Phase Full Converter Drives

Input Power of Single Phase Full Converter Drives Solution

Follow our step by step solution on how to calculate Input Power of Single Phase Full Converter Drives?

FIRST Step Consider the formula
Pin=(22π)cos(α)
Next Step Substitute values of Variables
Pin=(22π)cos(70°)
Next Step Substitute values of Constants
Pin=(223.1416)cos(70°)
Next Step Convert Units
Pin=(223.1416)cos(1.2217rad)
Next Step Prepare to Evaluate
Pin=(223.1416)cos(1.2217)
Next Step Evaluate
Pin=0.307926315490687W
LAST Step Rounding Answer
Pin=0.3079W

Input Power of Single Phase Full Converter Drives Formula Elements

Variables
Constants
Functions
Input Power
Input Power of single-phase full converter drive is an electronic control system used to regulate the speed and direction of single-phase alternating current (AC) motors.
Symbol: Pin
Measurement: PowerUnit: W
Note: Value should be greater than 0.
Delay Angle of Thyristor
Delay Angle of Thyristor is the angle at which thyristors are triggered after zero crossing.
Symbol: α
Measurement: AngleUnit: °
Note: Value can be positive or negative.
Archimedes' constant
Archimedes' constant is a mathematical constant that represents the ratio of the circumference of a circle to its diameter.
Symbol: π
Value: 3.14159265358979323846264338327950288
cos
Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
Syntax: cos(Angle)
sqrt
A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
Syntax: sqrt(Number)

Other formulas in Single Phase Drives category

​Go Average Armature Voltage of Single Phase Half-Wave Converter Drive
Va(half)=Vm2π(1+cos(α))
​Go Average Field Voltage of Single Phase Semi-Converter Drives
Vf(semi)=(Vmπ)(1+cos(α))
​Go Average Armature Voltage of Single Phase Full-Converter Drives
Va(full)=2Vmcos(α)π
​Go RMS Value of Thyristor Current in Half Wave Converter Drives
Isr=Ia(π-α2π)12

How to Evaluate Input Power of Single Phase Full Converter Drives?

Input Power of Single Phase Full Converter Drives evaluator uses Input Power = ((2*sqrt(2))/pi)*cos(Delay Angle of Thyristor) to evaluate the Input Power, Input Power of Single Phase Full Converter Drives is an electronic control system used to regulate the speed and direction of single-phase alternating current (AC) motors. It typically consists of a power electronic converter that converts AC power to direct current (DC), and then an inverter that converts the DC back to AC with variable voltage and frequency, allowing for precise control of the motor. Input Power is denoted by Pin symbol.

How to evaluate Input Power of Single Phase Full Converter Drives using this online evaluator? To use this online evaluator for Input Power of Single Phase Full Converter Drives, enter Delay Angle of Thyristor (α) and hit the calculate button.

FAQs on Input Power of Single Phase Full Converter Drives

What is the formula to find Input Power of Single Phase Full Converter Drives?
The formula of Input Power of Single Phase Full Converter Drives is expressed as Input Power = ((2*sqrt(2))/pi)*cos(Delay Angle of Thyristor). Here is an example- 0.307926 = ((2*sqrt(2))/pi)*cos(1.2217304763958).
How to calculate Input Power of Single Phase Full Converter Drives?
With Delay Angle of Thyristor (α) we can find Input Power of Single Phase Full Converter Drives using the formula - Input Power = ((2*sqrt(2))/pi)*cos(Delay Angle of Thyristor). This formula also uses Archimedes' constant and , Cosine (cos), Square Root (sqrt) function(s).
Can the Input Power of Single Phase Full Converter Drives be negative?
No, the Input Power of Single Phase Full Converter Drives, measured in Power cannot be negative.
Which unit is used to measure Input Power of Single Phase Full Converter Drives?
Input Power of Single Phase Full Converter Drives is usually measured using the Watt[W] for Power. Kilowatt[W], Milliwatt[W], Microwatt[W] are the few other units in which Input Power of Single Phase Full Converter Drives can be measured.
Copied!