Qi=0.6Ao((2gD)12)
Qi - Inlet Capacity?Ao - Area of Opening?g - Acceleration due to Gravity?D - Depth?

Inlet Capacity for Flow Depth more than 1ft 5in Example

With values
With units
Only example

Here is how the Inlet Capacity for Flow Depth more than 1ft 5in equation looks like with Values.

Here is how the Inlet Capacity for Flow Depth more than 1ft 5in equation looks like with Units.

Here is how the Inlet Capacity for Flow Depth more than 1ft 5in equation looks like.

41.9967Edit=0.69.128Edit((29.8Edit3Edit)12)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Inlet Capacity for Flow Depth more than 1ft 5in

Inlet Capacity for Flow Depth more than 1ft 5in Solution

Follow our step by step solution on how to calculate Inlet Capacity for Flow Depth more than 1ft 5in?

FIRST Step Consider the formula
Qi=0.6Ao((2gD)12)
Next Step Substitute values of Variables
Qi=0.69.128((29.8m/s²3m)12)
Next Step Prepare to Evaluate
Qi=0.69.128((29.83)12)
Next Step Evaluate
Qi=41.9967366412201m³/s
LAST Step Rounding Answer
Qi=41.9967m³/s

Inlet Capacity for Flow Depth more than 1ft 5in Formula Elements

Variables
Inlet Capacity
The Inlet Capacity refers to the maximum rate at which a storm water inlet or drainage structure can accept and convey water without causing flooding or other adverse impacts.
Symbol: Qi
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Area of Opening
The Area of Opening refers to the physical space in a structure or barrier through which air, water, or other substances can pass.
Symbol: Ao
Measurement: AreaUnit:
Note: Value should be greater than 0.
Acceleration due to Gravity
Acceleration due to Gravity is acceleration gained by an object because of gravitational force.
Symbol: g
Measurement: AccelerationUnit: m/s²
Note: Value should be greater than 0.
Depth
The Depth refers to the vertical distance from a reference point to the bottom of a body of water or to a specific depth below the water surface.
Symbol: D
Measurement: LengthUnit: m
Note: Value can be positive or negative.

Other formulas in Disposing of Storm Water category

​Go Runoff Quantity with Full Gutter Flow
Qro=0.7Lo(a+y)32
​Go Length of Opening given Runoff Quantity with Full Gutter Flow
Lo=Qro0.7(a+y)32
​Go Depression in Curb Inlet given Runoff Quantity with Full Gutter flow
a=((Qro0.7Lo)23)-y
​Go Depth of Flow at Inlet given Runoff Quantity with Full Gutter Flow
y=((Qro0.7Lo)23)-a

How to Evaluate Inlet Capacity for Flow Depth more than 1ft 5in?

Inlet Capacity for Flow Depth more than 1ft 5in evaluator uses Inlet Capacity = 0.6*Area of Opening*((2*Acceleration due to Gravity*Depth)^(1/2)) to evaluate the Inlet Capacity, The Inlet capacity for flow depth more than 1ft 5in is defined as the measures the flow in sewer pipes in terms of cubic meter of flow per day. Inlet Capacity is denoted by Qi symbol.

How to evaluate Inlet Capacity for Flow Depth more than 1ft 5in using this online evaluator? To use this online evaluator for Inlet Capacity for Flow Depth more than 1ft 5in, enter Area of Opening (Ao), Acceleration due to Gravity (g) & Depth (D) and hit the calculate button.

FAQs on Inlet Capacity for Flow Depth more than 1ft 5in

What is the formula to find Inlet Capacity for Flow Depth more than 1ft 5in?
The formula of Inlet Capacity for Flow Depth more than 1ft 5in is expressed as Inlet Capacity = 0.6*Area of Opening*((2*Acceleration due to Gravity*Depth)^(1/2)). Here is an example- 41.99674 = 0.6*9.128*((2*9.8*3)^(1/2)).
How to calculate Inlet Capacity for Flow Depth more than 1ft 5in?
With Area of Opening (Ao), Acceleration due to Gravity (g) & Depth (D) we can find Inlet Capacity for Flow Depth more than 1ft 5in using the formula - Inlet Capacity = 0.6*Area of Opening*((2*Acceleration due to Gravity*Depth)^(1/2)).
Can the Inlet Capacity for Flow Depth more than 1ft 5in be negative?
No, the Inlet Capacity for Flow Depth more than 1ft 5in, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Inlet Capacity for Flow Depth more than 1ft 5in?
Inlet Capacity for Flow Depth more than 1ft 5in is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Inlet Capacity for Flow Depth more than 1ft 5in can be measured.
Copied!