Inlet Air Humidity based on Adiabatic Saturation Temperature Formula

Fx Copy
LaTeX Copy
Inlet Air Humidity refers to the actual amount of water vapor present in a unit volume of incoming air. Check FAQs
Y'=YS'-(TG-TS)(CsλS)
Y' - Inlet Air Humidity?YS' - Saturated Exit Air Humidity?TG - Temperature of Air?TS - Adiabatic Saturation Temperature?Cs - Humid Heat?λS - Heat of Vaporization at Adiabatic Saturation Temp?

Inlet Air Humidity based on Adiabatic Saturation Temperature Example

With values
With units
Only example

Here is how the Inlet Air Humidity based on Adiabatic Saturation Temperature equation looks like with Values.

Here is how the Inlet Air Humidity based on Adiabatic Saturation Temperature equation looks like with Units.

Here is how the Inlet Air Humidity based on Adiabatic Saturation Temperature equation looks like.

0.0102Edit=0.0172Edit-(30Edit-22.5Edit)(2.1Edit2250Edit)
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Mass Transfer Operations » fx Inlet Air Humidity based on Adiabatic Saturation Temperature

Inlet Air Humidity based on Adiabatic Saturation Temperature Solution

Follow our step by step solution on how to calculate Inlet Air Humidity based on Adiabatic Saturation Temperature?

FIRST Step Consider the formula
Y'=YS'-(TG-TS)(CsλS)
Next Step Substitute values of Variables
Y'=0.0172kg/kg of air-(30°C-22.5°C)(2.1kJ/kg*K2250kJ/kg)
Next Step Convert Units
Y'=0.0172kg/kg of air-(303.15K-295.65K)(2100J/(kg*K)2.3E+6J/kg)
Next Step Prepare to Evaluate
Y'=0.0172-(303.15-295.65)(21002.3E+6)
LAST Step Evaluate
Y'=0.0102kg/kg of air

Inlet Air Humidity based on Adiabatic Saturation Temperature Formula Elements

Variables
Inlet Air Humidity
Inlet Air Humidity refers to the actual amount of water vapor present in a unit volume of incoming air.
Symbol: Y'
Measurement: Specific HumidityUnit: kg/kg of air
Note: Value should be greater than -1E-08.
Saturated Exit Air Humidity
Saturated exit air humidity is the level of water vapor in air that has reached its saturation point, often expressed as the maximum amount of moisture the air can hold at a specific temperature.
Symbol: YS'
Measurement: Specific HumidityUnit: kg/kg of air
Note: Value should be greater than -1E-08.
Temperature of Air
The Temperature of Air is defined as the temperature at which the air-water mixture properties in humidification are calculated.
Symbol: TG
Measurement: TemperatureUnit: °C
Note: Value should be greater than -273.15.
Adiabatic Saturation Temperature
Adiabatic saturation temperature is the temperature achieved when moist air undergoes an adiabatic process while being saturated with water vapor.
Symbol: TS
Measurement: TemperatureUnit: °C
Note: Value should be greater than -273.15.
Humid Heat
Humid Heat -The Heat capacity of 1Kg dry gas/air and whatever vapour/moisture contained in it. The heat capacity of humid air, expressed per unit mass of dry air in the mixture.
Symbol: Cs
Measurement: Specific Heat CapacityUnit: kJ/kg*K
Note: Value should be greater than 0.
Heat of Vaporization at Adiabatic Saturation Temp
The heat of vaporization at adiabatic saturation temperature is the energy required per unit mass to convert liquid water into vapor during an adiabatic process.
Symbol: λS
Measurement: Latent HeatUnit: kJ/kg
Note: Value should be greater than 0.

Other formulas in Adiabatic Saturation Temperature and Wet Bulb Temperature category

​Go Adiabatic Saturation Temperature
TS=TG-(YS'-Y')(λSCs)
​Go Air Inlet Temperature based on Adiabatic Saturation Temperature
TG=(YS'-Y')(λSCs)+TS
​Go Humid Heat of Air based on Adiabatic Saturation Temperature
Cs=YS'-Y'TG-TSλS
​Go Latent Heat of Air based on Adiabatic Saturation Temperature
λS=TG-TSYS'-Y'Cs

How to Evaluate Inlet Air Humidity based on Adiabatic Saturation Temperature?

Inlet Air Humidity based on Adiabatic Saturation Temperature evaluator uses Inlet Air Humidity = Saturated Exit Air Humidity-(Temperature of Air-Adiabatic Saturation Temperature)*(Humid Heat/Heat of Vaporization at Adiabatic Saturation Temp) to evaluate the Inlet Air Humidity, The Inlet Air Humidity based on Adiabatic Saturation Temperature formula is defined as humidity of the inlet air required for the air undergoing an adiabatic humidification process, calculated based on adiabatic saturation temperature. Inlet Air Humidity is denoted by Y' symbol.

How to evaluate Inlet Air Humidity based on Adiabatic Saturation Temperature using this online evaluator? To use this online evaluator for Inlet Air Humidity based on Adiabatic Saturation Temperature, enter Saturated Exit Air Humidity (YS'), Temperature of Air (TG), Adiabatic Saturation Temperature (TS), Humid Heat (Cs) & Heat of Vaporization at Adiabatic Saturation Temp S) and hit the calculate button.

FAQs on Inlet Air Humidity based on Adiabatic Saturation Temperature

What is the formula to find Inlet Air Humidity based on Adiabatic Saturation Temperature?
The formula of Inlet Air Humidity based on Adiabatic Saturation Temperature is expressed as Inlet Air Humidity = Saturated Exit Air Humidity-(Temperature of Air-Adiabatic Saturation Temperature)*(Humid Heat/Heat of Vaporization at Adiabatic Saturation Temp). Here is an example- 0.0102 = 0.0172-(303.15-295.65)*(2100/2250000).
How to calculate Inlet Air Humidity based on Adiabatic Saturation Temperature?
With Saturated Exit Air Humidity (YS'), Temperature of Air (TG), Adiabatic Saturation Temperature (TS), Humid Heat (Cs) & Heat of Vaporization at Adiabatic Saturation Temp S) we can find Inlet Air Humidity based on Adiabatic Saturation Temperature using the formula - Inlet Air Humidity = Saturated Exit Air Humidity-(Temperature of Air-Adiabatic Saturation Temperature)*(Humid Heat/Heat of Vaporization at Adiabatic Saturation Temp).
Can the Inlet Air Humidity based on Adiabatic Saturation Temperature be negative?
Yes, the Inlet Air Humidity based on Adiabatic Saturation Temperature, measured in Specific Humidity can be negative.
Which unit is used to measure Inlet Air Humidity based on Adiabatic Saturation Temperature?
Inlet Air Humidity based on Adiabatic Saturation Temperature is usually measured using the Kg of water vapour per Kg of air[kg/kg of air] for Specific Humidity. are the few other units in which Inlet Air Humidity based on Adiabatic Saturation Temperature can be measured.
Copied!