Fx Copy
LaTeX Copy
Initial reactor volume is the volume of the reactor before the initiation of the reaction. Check FAQs
V0=V1+ε
V0 - Initial Reactor Volume?V - Volume in Varying Volume Batch Reactor?ε - Fractional Volume Change?

Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor Example

With values
With units
Only example

Here is how the Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor equation looks like with Values.

Here is how the Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor equation looks like with Units.

Here is how the Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor equation looks like.

12.8205Edit=15Edit1+0.17Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Chemical Reaction Engineering » fx Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor

Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor Solution

Follow our step by step solution on how to calculate Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor?

FIRST Step Consider the formula
V0=V1+ε
Next Step Substitute values of Variables
V0=151+0.17
Next Step Prepare to Evaluate
V0=151+0.17
Next Step Evaluate
V0=12.8205128205128
LAST Step Rounding Answer
V0=12.8205

Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor Formula Elements

Variables
Initial Reactor Volume
Initial reactor volume is the volume of the reactor before the initiation of the reaction.
Symbol: V0
Measurement: VolumeUnit:
Note: Value can be positive or negative.
Volume in Varying Volume Batch Reactor
Volume in Varying Volume Batch Reactor is the amount of space that a reactor occupies at given time when volume is varying.
Symbol: V
Measurement: VolumeUnit:
Note: Value can be positive or negative.
Fractional Volume Change
Fractional Volume Change is the ratio of the change in volume and the initial volume.
Symbol: ε
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Initial Reactor Volume

​Go Initial Reactor Volume in Varying Volume Batch Reactor
V0=V1+εXA

Other formulas in Varying Volume Batch Reactor category

​Go Initial Partial Pressure of Product in Constant Volume Batch Reactor
pR0=pR-(RΔn)(π-π0)
​Go Initial Partial Pressure of Reactant in Constant Volume Batch Reactor
pA0=pA+(AΔn)(π-π0)
​Go Net Partial Pressure in Constant Volume Batch Reactor
Δp=r[R]TΔt
​Go Number of Moles of Reactant Fed to Constant Volume Batch Reactor
NAo=Vsolution(CA+(AΔn)(NT-N0Vsolution))

How to Evaluate Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor?

Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor evaluator uses Initial Reactor Volume = Volume in Varying Volume Batch Reactor/(1+Fractional Volume Change) to evaluate the Initial Reactor Volume, The Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor formula is defined as the initial volume of variable volume batch reactor in which the reactant undergoes complete conversion. Initial Reactor Volume is denoted by V0 symbol.

How to evaluate Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor using this online evaluator? To use this online evaluator for Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor, enter Volume in Varying Volume Batch Reactor (V) & Fractional Volume Change (ε) and hit the calculate button.

FAQs on Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor

What is the formula to find Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor?
The formula of Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor is expressed as Initial Reactor Volume = Volume in Varying Volume Batch Reactor/(1+Fractional Volume Change). Here is an example- 13.04348 = 15/(1+0.17).
How to calculate Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor?
With Volume in Varying Volume Batch Reactor (V) & Fractional Volume Change (ε) we can find Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor using the formula - Initial Reactor Volume = Volume in Varying Volume Batch Reactor/(1+Fractional Volume Change).
What are the other ways to Calculate Initial Reactor Volume?
Here are the different ways to Calculate Initial Reactor Volume-
  • Initial Reactor Volume=Volume in Varying Volume Batch Reactor/(1+Fractional Volume Change*Reactant Conversion)OpenImg
Can the Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor be negative?
Yes, the Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor, measured in Volume can be negative.
Which unit is used to measure Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor?
Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor is usually measured using the Cubic Meter[m³] for Volume. Cubic Centimeter[m³], Cubic Millimeter[m³], Liter[m³] are the few other units in which Initial Reactor Volume at Complete Conversion in Varying Volume Batch Reactor can be measured.
Copied!