Fx Copy
LaTeX Copy
Reactant Conversion gives us the percentage of reactants converted into products. Enter the percentage as a decimal between 0 and 1. Check FAQs
XA=Co-CCo+εC
XA - Reactant Conversion?Co - Initial Reactant Concentration?C - Reactant Concentration?ε - Fractional Volume Change?

Initial Reactant Conversion using Reactant Concentration with Varying Density Example

With values
With units
Only example

Here is how the Initial Reactant Conversion using Reactant Concentration with Varying Density equation looks like with Values.

Here is how the Initial Reactant Conversion using Reactant Concentration with Varying Density equation looks like with Units.

Here is how the Initial Reactant Conversion using Reactant Concentration with Varying Density equation looks like.

0.6585Edit=80Edit-24Edit80Edit+0.21Edit24Edit
You are here -
HomeIcon Home » Category Engineering » Category Chemical Engineering » Category Chemical Reaction Engineering » fx Initial Reactant Conversion using Reactant Concentration with Varying Density

Initial Reactant Conversion using Reactant Concentration with Varying Density Solution

Follow our step by step solution on how to calculate Initial Reactant Conversion using Reactant Concentration with Varying Density?

FIRST Step Consider the formula
XA=Co-CCo+εC
Next Step Substitute values of Variables
XA=80mol/m³-24mol/m³80mol/m³+0.2124mol/m³
Next Step Prepare to Evaluate
XA=80-2480+0.2124
Next Step Evaluate
XA=0.658513640639699
LAST Step Rounding Answer
XA=0.6585

Initial Reactant Conversion using Reactant Concentration with Varying Density Formula Elements

Variables
Reactant Conversion
Reactant Conversion gives us the percentage of reactants converted into products. Enter the percentage as a decimal between 0 and 1.
Symbol: XA
Measurement: NAUnit: Unitless
Note: Value should be less than 1.
Initial Reactant Concentration
The Initial Reactant Concentration refers to the amount of reactant present in the solvent before the considered process.
Symbol: Co
Measurement: Molar ConcentrationUnit: mol/m³
Note: Value should be greater than 0.
Reactant Concentration
The Reactant Concentration refers to the amount of reactant present in the solvent at any given point of time during the process.
Symbol: C
Measurement: Molar ConcentrationUnit: mol/m³
Note: Value should be greater than 0.
Fractional Volume Change
Fractional Volume Change is the ratio of the change in volume and the initial volume.
Symbol: ε
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.

Other Formulas to find Reactant Conversion

​Go Reactant Conversion using Reactant Concentration
XA=1-(CCo)

Other formulas in Introduction to Reactor Design category

​Go Initial Key Reactant Concentration with Varying Density,Temperature and Total Pressure
Ckey0=Ckey(1+εXkey1-Xkey)(TCREπ0T0π)
​Go Initial Reactant Concentration using Reactant Conversion
Co=C1-XA
​Go Initial Reactant Concentration using Reactant Conversion with Varying Density
IntialConc=(C)(1+εXA)1-XA
​Go Key Reactant Concentration with Varying Density,Temperature and Total Pressure
Ckey=Ckey0(1-Xkey1+εXkey)(T0πTCREπ0)

How to Evaluate Initial Reactant Conversion using Reactant Concentration with Varying Density?

Initial Reactant Conversion using Reactant Concentration with Varying Density evaluator uses Reactant Conversion = (Initial Reactant Concentration-Reactant Concentration)/(Initial Reactant Concentration+Fractional Volume Change*Reactant Concentration) to evaluate the Reactant Conversion, Initial Reactant Conversion using Reactant Concentration with Varying Densityformula is defined as the fraction of reactant converted till the given time where density is changing and temperature and total pressure are constant in both batch and flow system. Reactant Conversion is denoted by XA symbol.

How to evaluate Initial Reactant Conversion using Reactant Concentration with Varying Density using this online evaluator? To use this online evaluator for Initial Reactant Conversion using Reactant Concentration with Varying Density, enter Initial Reactant Concentration (Co), Reactant Concentration (C) & Fractional Volume Change (ε) and hit the calculate button.

FAQs on Initial Reactant Conversion using Reactant Concentration with Varying Density

What is the formula to find Initial Reactant Conversion using Reactant Concentration with Varying Density?
The formula of Initial Reactant Conversion using Reactant Concentration with Varying Density is expressed as Reactant Conversion = (Initial Reactant Concentration-Reactant Concentration)/(Initial Reactant Concentration+Fractional Volume Change*Reactant Concentration). Here is an example- 0.658514 = (80-24)/(80+0.21*24).
How to calculate Initial Reactant Conversion using Reactant Concentration with Varying Density?
With Initial Reactant Concentration (Co), Reactant Concentration (C) & Fractional Volume Change (ε) we can find Initial Reactant Conversion using Reactant Concentration with Varying Density using the formula - Reactant Conversion = (Initial Reactant Concentration-Reactant Concentration)/(Initial Reactant Concentration+Fractional Volume Change*Reactant Concentration).
What are the other ways to Calculate Reactant Conversion?
Here are the different ways to Calculate Reactant Conversion-
  • Reactant Conversion=1-(Reactant Concentration/Initial Reactant Concentration)OpenImg
Copied!