Depression and Interception Losses is the portion of the precipitation that is returned to the atmosphere through evaporation from plant surfaces . Check FAQs
Ia=P-R-(Wte)
Ia - Depression and Interception Losses?P - Total Storm Precipitation?R - Total Storm Runoff?W - W-Index?te - Duration of Rainfall Excess?

Initial Losses given W-Index Example

With values
With units
Only example

Here is how the Initial Losses given W-Index equation looks like with Values.

Here is how the Initial Losses given W-Index equation looks like with Units.

Here is how the Initial Losses given W-Index equation looks like.

6Edit=118Edit-48Edit-(16Edit4Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Initial Losses given W-Index

Initial Losses given W-Index Solution

Follow our step by step solution on how to calculate Initial Losses given W-Index?

FIRST Step Consider the formula
Ia=P-R-(Wte)
Next Step Substitute values of Variables
Ia=118cm-48cm-(16cm4h)
Next Step Prepare to Evaluate
Ia=118-48-(164)
Next Step Evaluate
Ia=0.06m
LAST Step Convert to Output's Unit
Ia=6cm

Initial Losses given W-Index Formula Elements

Variables
Depression and Interception Losses
Depression and Interception Losses is the portion of the precipitation that is returned to the atmosphere through evaporation from plant surfaces .
Symbol: Ia
Measurement: LengthUnit: cm
Note: Value can be positive or negative.
Total Storm Precipitation
Total Storm Precipitation is the annual precipitation of the current year.
Symbol: P
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Total Storm Runoff
Total Storm Runoff is rain that flows off building rooftops, driveways, lawns, streets, parking lots, construction sites, and industrial storage yards.
Symbol: R
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
W-Index
W-Index is the average infiltration rate during the time when the rainfall intensity exceeds the infiltration rate.
Symbol: W
Measurement: LengthUnit: cm
Note: Value should be greater than 0.
Duration of Rainfall Excess
Duration of Rainfall Excess is the total time in which the rainfall intensity the greater than the average rate of infiltration (in hours).
Symbol: te
Measurement: TimeUnit: h
Note: Value should be greater than 0.

Other formulas in W Index category

​Go W-Index
W=P-R-Iate
​Go Total Storm Precipitation when W Index
P=(Wte)+R+Ia
​Go Total Storm Runoff given W Index
R=P-Ia-(Wte)
​Go Duration of Rainfall Excess given W Index
te=P-R-IaW

How to Evaluate Initial Losses given W-Index?

Initial Losses given W-Index evaluator uses Depression and Interception Losses = Total Storm Precipitation-Total Storm Runoff-(W-Index*Duration of Rainfall Excess) to evaluate the Depression and Interception Losses, The Initial Losses given W-Index formula is defined as considering infiltration quantity, W-Index is the average infiltration rate during the entire period of the storm. In the calculation of W-Index, the initial loss is separated from the total infiltration. Depression and Interception Losses is denoted by Ia symbol.

How to evaluate Initial Losses given W-Index using this online evaluator? To use this online evaluator for Initial Losses given W-Index, enter Total Storm Precipitation (P), Total Storm Runoff (R), W-Index (W) & Duration of Rainfall Excess (te) and hit the calculate button.

FAQs on Initial Losses given W-Index

What is the formula to find Initial Losses given W-Index?
The formula of Initial Losses given W-Index is expressed as Depression and Interception Losses = Total Storm Precipitation-Total Storm Runoff-(W-Index*Duration of Rainfall Excess). Here is an example- 600 = 1.18-0.48-(0.16*14400).
How to calculate Initial Losses given W-Index?
With Total Storm Precipitation (P), Total Storm Runoff (R), W-Index (W) & Duration of Rainfall Excess (te) we can find Initial Losses given W-Index using the formula - Depression and Interception Losses = Total Storm Precipitation-Total Storm Runoff-(W-Index*Duration of Rainfall Excess).
Can the Initial Losses given W-Index be negative?
Yes, the Initial Losses given W-Index, measured in Length can be negative.
Which unit is used to measure Initial Losses given W-Index?
Initial Losses given W-Index is usually measured using the Centimeter[cm] for Length. Meter[cm], Millimeter[cm], Kilometer[cm] are the few other units in which Initial Losses given W-Index can be measured.
Copied!