Initial Concentration of Reactant A for Set of Three Parallel Reactions Formula

Fx Copy
LaTeX Copy
Initial Concentration of Reactant A is defined as the concentration of the reactant A at time t=0. Check FAQs
A0=RAexp((k1+k2+k3)t)
A0 - Initial Concentration of Reactant A?RA - Reactant A Concentration?k1 - Reaction Rate Constant 1?k2 - Reaction Rate Constant 2?k3 - Rate Constant of Reaction 3?t - Time?

Initial Concentration of Reactant A for Set of Three Parallel Reactions Example

With values
With units
Only example

Here is how the Initial Concentration of Reactant A for Set of Three Parallel Reactions equation looks like with Values.

Here is how the Initial Concentration of Reactant A for Set of Three Parallel Reactions equation looks like with Units.

Here is how the Initial Concentration of Reactant A for Set of Three Parallel Reactions equation looks like.

96.214Edit=60.5Editexp((5.7E-6Edit+8.9E-5Edit+3.5E-5Edit)3600Edit)
You are here -
HomeIcon Home » Category Chemistry » Category Chemical Kinetics » Category Complex Reactions » fx Initial Concentration of Reactant A for Set of Three Parallel Reactions

Initial Concentration of Reactant A for Set of Three Parallel Reactions Solution

Follow our step by step solution on how to calculate Initial Concentration of Reactant A for Set of Three Parallel Reactions?

FIRST Step Consider the formula
A0=RAexp((k1+k2+k3)t)
Next Step Substitute values of Variables
A0=60.5mol/Lexp((5.7E-6s⁻¹+8.9E-5s⁻¹+3.5E-5s⁻¹)3600s)
Next Step Convert Units
A0=60500mol/m³exp((5.7E-6s⁻¹+8.9E-5s⁻¹+3.5E-5s⁻¹)3600s)
Next Step Prepare to Evaluate
A0=60500exp((5.7E-6+8.9E-5+3.5E-5)3600)
Next Step Evaluate
A0=96214.0469339789mol/m³
Next Step Convert to Output's Unit
A0=96.2140469339789mol/L
LAST Step Rounding Answer
A0=96.214mol/L

Initial Concentration of Reactant A for Set of Three Parallel Reactions Formula Elements

Variables
Functions
Initial Concentration of Reactant A
Initial Concentration of Reactant A is defined as the concentration of the reactant A at time t=0.
Symbol: A0
Measurement: Molar ConcentrationUnit: mol/L
Note: Value should be greater than 0.
Reactant A Concentration
Reactant A Concentration is defined as the concentration of substance A after reacting for a given interval of time t.
Symbol: RA
Measurement: Molar ConcentrationUnit: mol/L
Note: Value should be greater than -1.
Reaction Rate Constant 1
Reaction Rate Constant 1 is defined as proportionality constant relating to the rate of the chemical reaction to the conc. of reactant or product in reaction 1.
Symbol: k1
Measurement: First Order Reaction Rate ConstantUnit: s⁻¹
Note: Value should be greater than -1.
Reaction Rate Constant 2
Reaction Rate Constant 2 is the proportionality constant relating to the rate of the chemical reaction to the conc. of the reactant or product in chemical reaction 2.
Symbol: k2
Measurement: First Order Reaction Rate ConstantUnit: s⁻¹
Note: Value should be greater than -1.
Rate Constant of Reaction 3
Rate Constant of reaction 3 is the proportionality constant relating to the rate of the chemical reaction to the conc. of reactant or product in chemical reaction 3.
Symbol: k3
Measurement: First Order Reaction Rate ConstantUnit: s⁻¹
Note: Value should be greater than 0.
Time
Time is used to defined as the period of time that is required for the reactant to given a certain amount of product in a chemical reaction.
Symbol: t
Measurement: TimeUnit: s
Note: Value should be greater than -1.
exp
n an exponential function, the value of the function changes by a constant factor for every unit change in the independent variable.
Syntax: exp(Number)

Other formulas in Kinetics for Set of Three Parallel Reactions category

​Go Time taken for Set of Three Parallel Reactions
t=1k1+k2+k3ln(A0RA)
​Go Rate Constant for Reaction A to B for Set of Three Parallel Reactions
k1=1tln(A0RA)-(k2+k3)
​Go Rate Constant for Reaction A to C for Set of Three Parallel Reactions
k2=1tln(A0RA)-(k1+k3)
​Go Rate Constant for Reaction A to D for Set of Three Parallel Reactions
k3=1tln(A0RA)-(k1+k2)

How to Evaluate Initial Concentration of Reactant A for Set of Three Parallel Reactions?

Initial Concentration of Reactant A for Set of Three Parallel Reactions evaluator uses Initial Concentration of Reactant A = Reactant A Concentration*exp((Reaction Rate Constant 1+Reaction Rate Constant 2+Rate Constant of Reaction 3)*Time) to evaluate the Initial Concentration of Reactant A, The Initial Concentration of Reactant A for Set of Three Parallel Reactions formula is defined as amount of reactant A present in the reacting system when t=0. Initial Concentration of Reactant A is denoted by A0 symbol.

How to evaluate Initial Concentration of Reactant A for Set of Three Parallel Reactions using this online evaluator? To use this online evaluator for Initial Concentration of Reactant A for Set of Three Parallel Reactions, enter Reactant A Concentration (RA), Reaction Rate Constant 1 (k1), Reaction Rate Constant 2 (k2), Rate Constant of Reaction 3 (k3) & Time (t) and hit the calculate button.

FAQs on Initial Concentration of Reactant A for Set of Three Parallel Reactions

What is the formula to find Initial Concentration of Reactant A for Set of Three Parallel Reactions?
The formula of Initial Concentration of Reactant A for Set of Three Parallel Reactions is expressed as Initial Concentration of Reactant A = Reactant A Concentration*exp((Reaction Rate Constant 1+Reaction Rate Constant 2+Rate Constant of Reaction 3)*Time). Here is an example- 0.096214 = 60500*exp((5.67E-06+8.87E-05+3.45E-05)*3600).
How to calculate Initial Concentration of Reactant A for Set of Three Parallel Reactions?
With Reactant A Concentration (RA), Reaction Rate Constant 1 (k1), Reaction Rate Constant 2 (k2), Rate Constant of Reaction 3 (k3) & Time (t) we can find Initial Concentration of Reactant A for Set of Three Parallel Reactions using the formula - Initial Concentration of Reactant A = Reactant A Concentration*exp((Reaction Rate Constant 1+Reaction Rate Constant 2+Rate Constant of Reaction 3)*Time). This formula also uses Exponential Growth Function function(s).
Can the Initial Concentration of Reactant A for Set of Three Parallel Reactions be negative?
Yes, the Initial Concentration of Reactant A for Set of Three Parallel Reactions, measured in Molar Concentration can be negative.
Which unit is used to measure Initial Concentration of Reactant A for Set of Three Parallel Reactions?
Initial Concentration of Reactant A for Set of Three Parallel Reactions is usually measured using the Mole per Liter[mol/L] for Molar Concentration. Mole per Cubic Meter[mol/L], Mole per Cubic Millimeter[mol/L], Kilomole per Cubic Meter[mol/L] are the few other units in which Initial Concentration of Reactant A for Set of Three Parallel Reactions can be measured.
Copied!