Fx Copy
LaTeX Copy
Influent Substrate Concentration refers to the concentration of organic matter or nutrients in the raw wastewater entering a treatment plant. Check FAQs
So=(Px8.34YobsQa)+S
So - Influent Substrate Concentration?Px - Net Waste Activated Sludge?Yobs - Observed Cell Yield?Qa - Average Daily Influent Flow Rate?S - Effluent Substrate Concentration?

Influent Substrate Concentration given Net Waste Activated Sludge Example

With values
With units
Only example

Here is how the Influent Substrate Concentration given Net Waste Activated Sludge equation looks like with Values.

Here is how the Influent Substrate Concentration given Net Waste Activated Sludge equation looks like with Units.

Here is how the Influent Substrate Concentration given Net Waste Activated Sludge equation looks like.

15.0025Edit=(20Edit8.340.8Edit1.2Edit)+15Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Influent Substrate Concentration given Net Waste Activated Sludge

Influent Substrate Concentration given Net Waste Activated Sludge Solution

Follow our step by step solution on how to calculate Influent Substrate Concentration given Net Waste Activated Sludge?

FIRST Step Consider the formula
So=(Px8.34YobsQa)+S
Next Step Substitute values of Variables
So=(20mg/d8.340.81.2m³/d)+15mg/L
Next Step Convert Units
So=(2.3E-10kg/s8.340.81.4E-5m³/s)+0.015kg/m³
Next Step Prepare to Evaluate
So=(2.3E-108.340.81.4E-5)+0.015
Next Step Evaluate
So=0.0150024980015987kg/m³
Next Step Convert to Output's Unit
So=15.0024980015987mg/L
LAST Step Rounding Answer
So=15.0025mg/L

Influent Substrate Concentration given Net Waste Activated Sludge Formula Elements

Variables
Influent Substrate Concentration
Influent Substrate Concentration refers to the concentration of organic matter or nutrients in the raw wastewater entering a treatment plant.
Symbol: So
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Net Waste Activated Sludge
Net Waste Activated Sludge is the amount of waste product that can be treated using the activated sludge process.
Symbol: Px
Measurement: Mass Flow RateUnit: mg/d
Note: Value should be greater than 0.
Observed Cell Yield
Observed Cell Yield refers to the observed mg of cells produced per mg organic matter removed.
Symbol: Yobs
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Average Daily Influent Flow Rate
Average Daily Influent Flow Rate is the total discharge that comes in the reactor.
Symbol: Qa
Measurement: Volumetric Flow RateUnit: m³/d
Note: Value should be greater than 0.
Effluent Substrate Concentration
Effluent Substrate Concentration refers to the concentration of organic matter or nutrients present in the treated wastewater (effluent) that is discharged from a wastewater treatment plant.
Symbol: S
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.

Other Formulas to find Influent Substrate Concentration

​Go Influent Substrate Concentration given Theoretical Oxygen Requirement
So=(O2+(1.42Px))(f8.34Qa)+S
​Go Influent Substrate Concentration given Organic Loading
So=VLVQi
​Go Influent Substrate Concentration for Organic Loading using Hydraulic Retention Time
So=VLθs

How to Evaluate Influent Substrate Concentration given Net Waste Activated Sludge?

Influent Substrate Concentration given Net Waste Activated Sludge evaluator uses Influent Substrate Concentration = (Net Waste Activated Sludge/(8.34*Observed Cell Yield*Average Daily Influent Flow Rate))+Effluent Substrate Concentration to evaluate the Influent Substrate Concentration, The Influent Substrate Concentration given Net Waste Activated Sludge is the total amount of BOD present in the incoming sewage. Influent Substrate Concentration is denoted by So symbol.

How to evaluate Influent Substrate Concentration given Net Waste Activated Sludge using this online evaluator? To use this online evaluator for Influent Substrate Concentration given Net Waste Activated Sludge, enter Net Waste Activated Sludge (Px), Observed Cell Yield (Yobs), Average Daily Influent Flow Rate (Qa) & Effluent Substrate Concentration (S) and hit the calculate button.

FAQs on Influent Substrate Concentration given Net Waste Activated Sludge

What is the formula to find Influent Substrate Concentration given Net Waste Activated Sludge?
The formula of Influent Substrate Concentration given Net Waste Activated Sludge is expressed as Influent Substrate Concentration = (Net Waste Activated Sludge/(8.34*Observed Cell Yield*Average Daily Influent Flow Rate))+Effluent Substrate Concentration. Here is an example- 15002.5 = (2.31481481481481E-10/(8.34*0.8*1.38888888888889E-05))+0.015.
How to calculate Influent Substrate Concentration given Net Waste Activated Sludge?
With Net Waste Activated Sludge (Px), Observed Cell Yield (Yobs), Average Daily Influent Flow Rate (Qa) & Effluent Substrate Concentration (S) we can find Influent Substrate Concentration given Net Waste Activated Sludge using the formula - Influent Substrate Concentration = (Net Waste Activated Sludge/(8.34*Observed Cell Yield*Average Daily Influent Flow Rate))+Effluent Substrate Concentration.
What are the other ways to Calculate Influent Substrate Concentration?
Here are the different ways to Calculate Influent Substrate Concentration-
  • Influent Substrate Concentration=(Theoretical Oxygen Requirement+(1.42*Net Waste Activated Sludge))*(BOD Conversion Factor/(8.34*Average Daily Influent Flow Rate))+Effluent Substrate ConcentrationOpenImg
  • Influent Substrate Concentration=Organic Loading*Reactor Volume/Influent Average Flow RateOpenImg
  • Influent Substrate Concentration=Organic Loading*Hydraulic Retention Time in SecondsOpenImg
Can the Influent Substrate Concentration given Net Waste Activated Sludge be negative?
No, the Influent Substrate Concentration given Net Waste Activated Sludge, measured in Density cannot be negative.
Which unit is used to measure Influent Substrate Concentration given Net Waste Activated Sludge?
Influent Substrate Concentration given Net Waste Activated Sludge is usually measured using the Milligram per Liter[mg/L] for Density. Kilogram per Cubic Meter[mg/L], Kilogram per Cubic Centimeter[mg/L], Gram per Cubic Meter[mg/L] are the few other units in which Influent Substrate Concentration given Net Waste Activated Sludge can be measured.
Copied!