Influent BOD given Volume of Aeration Tank Formula

Fx Copy
LaTeX Copy
Influent BOD is the total amount of BOD which is present in the incoming sewage. Check FAQs
Qi=Qo+(VX(1+Keθc)YQsθc)
Qi - Influent BOD?Qo - Effluent BOD?V - Volume of Tank?X - MLSS?Ke - Endogenous Respiration Rate Constant?θc - Sludge Age?Y - Maximum Yield Coefficient?Qs - Sewage Discharge?

Influent BOD given Volume of Aeration Tank Example

With values
With units
Only example

Here is how the Influent BOD given Volume of Aeration Tank equation looks like with Values.

Here is how the Influent BOD given Volume of Aeration Tank equation looks like with Units.

Here is how the Influent BOD given Volume of Aeration Tank equation looks like.

0.48Edit=0.4Edit+(9Edit1200Edit(1+3Edit5Edit)0.5Edit10Edit5Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Influent BOD given Volume of Aeration Tank

Influent BOD given Volume of Aeration Tank Solution

Follow our step by step solution on how to calculate Influent BOD given Volume of Aeration Tank?

FIRST Step Consider the formula
Qi=Qo+(VX(1+Keθc)YQsθc)
Next Step Substitute values of Variables
Qi=0.4mg/L+(91200mg/L(1+3d⁻¹5d)0.510m³/s5d)
Next Step Convert Units
Qi=0.0004kg/m³+(91.2kg/m³(1+3.5E-5s⁻¹432000s)0.510m³/s432000s)
Next Step Prepare to Evaluate
Qi=0.0004+(91.2(1+3.5E-5432000)0.510432000)
Next Step Evaluate
Qi=0.00048kg/m³
LAST Step Convert to Output's Unit
Qi=0.48mg/L

Influent BOD given Volume of Aeration Tank Formula Elements

Variables
Influent BOD
Influent BOD is the total amount of BOD which is present in the incoming sewage.
Symbol: Qi
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Effluent BOD
Effluent BOD is the amount of dissolved oxygen needed by aerobic biological organisms to break down organic material present in a water sample at a certain temperature over a specific time period.
Symbol: Qo
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Volume of Tank
Volume of Tank is defined as the capacity of flocculation and mixing tank.
Symbol: V
Measurement: VolumeUnit:
Note: Value should be greater than 0.
MLSS
MLSS is the sum of volatile suspended solids (organics) and fixed suspended solids (inorganics).
Symbol: X
Measurement: DensityUnit: mg/L
Note: Value should be between 1000 to 6500.
Endogenous Respiration Rate Constant
Endogenous Respiration Rate Constant is used for designing a complete-mix activated-sludge system.
Symbol: Ke
Measurement: First Order Reaction Rate ConstantUnit: d⁻¹
Note: Value should be greater than 0.
Sludge Age
Sludge Age is the average time for which the particle of suspended solids remains in aeration.
Symbol: θc
Measurement: TimeUnit: d
Note: Value should be greater than 0.
Maximum Yield Coefficient
Maximum Yield Coefficient Y represents the maximum mg of cells produced per mg organic matter removed.
Symbol: Y
Measurement: NAUnit: Unitless
Note: Value should be between 0.4 to 0.8.
Sewage Discharge
Sewage discharge is the flow rate of sewage when it is being discharged into the water body.
Symbol: Qs
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other formulas in Size and Volume of the Aeration Tank category

​Go Volume of Aeration Tank
V=YQs(Qi-Qo)θcX(1+Keθc)
​Go MLSS given volume of Aeration Tank
X=YQs(Qi-Qo)θcV(1+Keθc)

How to Evaluate Influent BOD given Volume of Aeration Tank?

Influent BOD given Volume of Aeration Tank evaluator uses Influent BOD = Effluent BOD+((Volume of Tank*MLSS*(1+Endogenous Respiration Rate Constant*Sludge Age))/(Maximum Yield Coefficient*Sewage Discharge*Sludge Age)) to evaluate the Influent BOD, The Influent BOD given Volume of Aeration Tank formula is defined as the influent BOD when we have prior information of volume of aeration tank. Influent BOD is denoted by Qi symbol.

How to evaluate Influent BOD given Volume of Aeration Tank using this online evaluator? To use this online evaluator for Influent BOD given Volume of Aeration Tank, enter Effluent BOD (Qo), Volume of Tank (V), MLSS (X), Endogenous Respiration Rate Constant (Ke), Sludge Age c), Maximum Yield Coefficient (Y) & Sewage Discharge (Qs) and hit the calculate button.

FAQs on Influent BOD given Volume of Aeration Tank

What is the formula to find Influent BOD given Volume of Aeration Tank?
The formula of Influent BOD given Volume of Aeration Tank is expressed as Influent BOD = Effluent BOD+((Volume of Tank*MLSS*(1+Endogenous Respiration Rate Constant*Sludge Age))/(Maximum Yield Coefficient*Sewage Discharge*Sludge Age)). Here is an example- 480 = 0.0004+((9*1.2*(1+3.47222222222222E-05*432000))/(0.5*10*432000)).
How to calculate Influent BOD given Volume of Aeration Tank?
With Effluent BOD (Qo), Volume of Tank (V), MLSS (X), Endogenous Respiration Rate Constant (Ke), Sludge Age c), Maximum Yield Coefficient (Y) & Sewage Discharge (Qs) we can find Influent BOD given Volume of Aeration Tank using the formula - Influent BOD = Effluent BOD+((Volume of Tank*MLSS*(1+Endogenous Respiration Rate Constant*Sludge Age))/(Maximum Yield Coefficient*Sewage Discharge*Sludge Age)).
Can the Influent BOD given Volume of Aeration Tank be negative?
No, the Influent BOD given Volume of Aeration Tank, measured in Density cannot be negative.
Which unit is used to measure Influent BOD given Volume of Aeration Tank?
Influent BOD given Volume of Aeration Tank is usually measured using the Milligram per Liter[mg/L] for Density. Kilogram per Cubic Meter[mg/L], Kilogram per Cubic Centimeter[mg/L], Gram per Cubic Meter[mg/L] are the few other units in which Influent BOD given Volume of Aeration Tank can be measured.
Copied!