Influent BOD is the total amount of BOD which is present in the incoming sewage. Check FAQs
Qi=Qb+(f(O2+(DO2QwXR))Qs)
Qi - Influent BOD?Qb - Effluent BOD given Oxygen Demand of Biomass?f - Ratio of BOD to Ultimate BOD?O2 - Theoretical Oxygen Requirement?DO2 - Oxygen Demand of Biomass?Qw - Volume of Wasted Sludge per day?XR - MLSS in Returned or Wasted Sludge?Qs - Sewage Discharge?

Influent BOD given Oxygen Demand of Biomass Example

With values
With units
Only example

Here is how the Influent BOD given Oxygen Demand of Biomass equation looks like with Values.

Here is how the Influent BOD given Oxygen Demand of Biomass equation looks like with Units.

Here is how the Influent BOD given Oxygen Demand of Biomass equation looks like.

15.2Edit=7.1402Edit+(3Edit(2.5Edit+(2.02Edit9.5Edit1.4Edit))10Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Influent BOD given Oxygen Demand of Biomass

Influent BOD given Oxygen Demand of Biomass Solution

Follow our step by step solution on how to calculate Influent BOD given Oxygen Demand of Biomass?

FIRST Step Consider the formula
Qi=Qb+(f(O2+(DO2QwXR))Qs)
Next Step Substitute values of Variables
Qi=7.1402mg/L+(3(2.5mg/d+(2.029.5m³/s1.4mg/L))10m³/s)
Next Step Convert Units
Qi=0.0071kg/m³+(3(2.9E-11kg/s+(2.029.5m³/s0.0014kg/m³))10m³/s)
Next Step Prepare to Evaluate
Qi=0.0071+(3(2.9E-11+(2.029.50.0014))10)
Next Step Evaluate
Qi=0.0152000000086806kg/m³
Next Step Convert to Output's Unit
Qi=15.2000000086806mg/L
LAST Step Rounding Answer
Qi=15.2mg/L

Influent BOD given Oxygen Demand of Biomass Formula Elements

Variables
Influent BOD
Influent BOD is the total amount of BOD which is present in the incoming sewage.
Symbol: Qi
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Effluent BOD given Oxygen Demand of Biomass
Effluent BOD given Oxygen Demand of Biomass is the amount of oxygen that is consumed by the microbial population in the effluent to decompose organic matter present.
Symbol: Qb
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Ratio of BOD to Ultimate BOD
Ratio of BOD to Ultimate BOD is the ratio of 5 days bod to ultimate bod.
Symbol: f
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Theoretical Oxygen Requirement
Theoretical Oxygen Requirement is the calculated amount of oxygen required to oxidize a compound to its final oxidation products.
Symbol: O2
Measurement: Mass Flow RateUnit: mg/d
Note: Value should be greater than 0.
Oxygen Demand of Biomass
Oxygen Demand of Biomass is the amount of oxygen required by the microorganisms to decompose organic matter present in biomass.
Symbol: DO2
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Volume of Wasted Sludge per day
Volume of Wasted Sludge per day is the amount of sludge that is removed or wasted from a wastewater treatment process on a daily basis.
Symbol: Qw
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
MLSS in Returned or Wasted Sludge
MLSS in Returned or Wasted Sludge is the mixed liquor suspended solids in returned sludge in terms of mg per liter.
Symbol: XR
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Sewage Discharge
Sewage Discharge is the flow rate of sewage when it is being discharged in the river.
Symbol: Qs
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other Formulas to find Influent BOD

​Go Influent BOD given Oxygen Required in Aeration Tank
Qi=Qo+(f(O2+(1.42QwXR))Qs)
​Go Influent BOD given Ultimate BOD
Qi=Qub+((BOD5BODu)(O2+(1.42QwXR))Qs)

How to Evaluate Influent BOD given Oxygen Demand of Biomass?

Influent BOD given Oxygen Demand of Biomass evaluator uses Influent BOD = Effluent BOD given Oxygen Demand of Biomass+((Ratio of BOD to Ultimate BOD*(Theoretical Oxygen Requirement+(Oxygen Demand of Biomass*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Discharge) to evaluate the Influent BOD, The Influent BOD given Oxygen Demand of Biomass formula is defined as the calculation of influent BOD when we have prior information of oxygen demand of biomass. Influent BOD is denoted by Qi symbol.

How to evaluate Influent BOD given Oxygen Demand of Biomass using this online evaluator? To use this online evaluator for Influent BOD given Oxygen Demand of Biomass, enter Effluent BOD given Oxygen Demand of Biomass (Qb), Ratio of BOD to Ultimate BOD (f), Theoretical Oxygen Requirement (O2), Oxygen Demand of Biomass (DO2), Volume of Wasted Sludge per day (Qw), MLSS in Returned or Wasted Sludge (XR) & Sewage Discharge (Qs) and hit the calculate button.

FAQs on Influent BOD given Oxygen Demand of Biomass

What is the formula to find Influent BOD given Oxygen Demand of Biomass?
The formula of Influent BOD given Oxygen Demand of Biomass is expressed as Influent BOD = Effluent BOD given Oxygen Demand of Biomass+((Ratio of BOD to Ultimate BOD*(Theoretical Oxygen Requirement+(Oxygen Demand of Biomass*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Discharge). Here is an example- 13200 = 0.0071402+((3*(2.89351851851852E-11+(2.02*9.5*0.0014)))/10).
How to calculate Influent BOD given Oxygen Demand of Biomass?
With Effluent BOD given Oxygen Demand of Biomass (Qb), Ratio of BOD to Ultimate BOD (f), Theoretical Oxygen Requirement (O2), Oxygen Demand of Biomass (DO2), Volume of Wasted Sludge per day (Qw), MLSS in Returned or Wasted Sludge (XR) & Sewage Discharge (Qs) we can find Influent BOD given Oxygen Demand of Biomass using the formula - Influent BOD = Effluent BOD given Oxygen Demand of Biomass+((Ratio of BOD to Ultimate BOD*(Theoretical Oxygen Requirement+(Oxygen Demand of Biomass*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Discharge).
What are the other ways to Calculate Influent BOD?
Here are the different ways to Calculate Influent BOD-
  • Influent BOD=Effluent BOD given Oxygen Required+((Ratio of BOD to Ultimate BOD*(Theoretical Oxygen Requirement+(1.42*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Discharge)OpenImg
  • Influent BOD=Effluent BOD given Ultimate BOD+(((5 Days BOD/Ultimate BOD)*(Theoretical Oxygen Requirement+(1.42*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Discharge)OpenImg
  • Influent BOD=Effluent BOD given Oxygen Demand and Ultimate BOD+(((5 Days BOD/Ultimate BOD)*(Theoretical Oxygen Requirement+(Oxygen Demand of Biomass*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Discharge)OpenImg
Can the Influent BOD given Oxygen Demand of Biomass be negative?
No, the Influent BOD given Oxygen Demand of Biomass, measured in Density cannot be negative.
Which unit is used to measure Influent BOD given Oxygen Demand of Biomass?
Influent BOD given Oxygen Demand of Biomass is usually measured using the Milligram per Liter[mg/L] for Density. Kilogram per Cubic Meter[mg/L], Kilogram per Cubic Centimeter[mg/L], Gram per Cubic Meter[mg/L] are the few other units in which Influent BOD given Oxygen Demand of Biomass can be measured.
Copied!