Fx Copy
LaTeX Copy
Influent BOD is the total amount of BOD which is present in the incoming sewage. Check FAQs
Qi=Qu+((BOD5BODu)(O2+(DO2QwXR))Qs)
Qi - Influent BOD?Qu - Effluent BOD given Oxygen Demand and Ultimate BOD?BOD5 - 5 Days BOD?BODu - Ultimate BOD?O2 - Theoretical Oxygen Requirement?DO2 - Oxygen Demand of Biomass?Qw - Volume of Wasted Sludge per day?XR - MLSS in Returned or Wasted Sludge?Qs - Sewage Discharge?

Influent BOD given Oxygen Demand and Ultimate BOD Both Example

With values
With units
Only example

Here is how the Influent BOD given Oxygen Demand and Ultimate BOD Both equation looks like with Values.

Here is how the Influent BOD given Oxygen Demand and Ultimate BOD Both equation looks like with Units.

Here is how the Influent BOD given Oxygen Demand and Ultimate BOD Both equation looks like.

13.1999Edit=11.373Edit+((1.36Edit2Edit)(2.5Edit+(2.02Edit9.5Edit1.4Edit))10Edit)
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Environmental Engineering » fx Influent BOD given Oxygen Demand and Ultimate BOD Both

Influent BOD given Oxygen Demand and Ultimate BOD Both Solution

Follow our step by step solution on how to calculate Influent BOD given Oxygen Demand and Ultimate BOD Both?

FIRST Step Consider the formula
Qi=Qu+((BOD5BODu)(O2+(DO2QwXR))Qs)
Next Step Substitute values of Variables
Qi=11.373mg/L+((1.36mg/L2mg/L)(2.5mg/d+(2.029.5m³/s1.4mg/L))10m³/s)
Next Step Convert Units
Qi=0.0114kg/m³+((0.0014kg/m³0.002kg/m³)(2.9E-11kg/s+(2.029.5m³/s0.0014kg/m³))10m³/s)
Next Step Prepare to Evaluate
Qi=0.0114+((0.00140.002)(2.9E-11+(2.029.50.0014))10)
Next Step Evaluate
Qi=0.0131998880019676kg/m³
Next Step Convert to Output's Unit
Qi=13.1998880019676mg/L
LAST Step Rounding Answer
Qi=13.1999mg/L

Influent BOD given Oxygen Demand and Ultimate BOD Both Formula Elements

Variables
Influent BOD
Influent BOD is the total amount of BOD which is present in the incoming sewage.
Symbol: Qi
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Effluent BOD given Oxygen Demand and Ultimate BOD
Effluent BOD given Oxygen Demand and Ultimate BOD is the amount of oxygen required by aerobic microorganisms to decompose the organic matter present in a wastewater sample.
Symbol: Qu
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
5 Days BOD
5 Days BOD is an indicator of how much oxygen is utilized by a natural water sample in five days at 20 degrees C.
Symbol: BOD5
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Ultimate BOD
Ultimate BOD is the amount of oxygen required to decompose all of the organic material after infinite time.
Symbol: BODu
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Theoretical Oxygen Requirement
Theoretical Oxygen Requirement is the calculated amount of oxygen required to oxidize a compound to its final oxidation products.
Symbol: O2
Measurement: Mass Flow RateUnit: mg/d
Note: Value should be greater than 0.
Oxygen Demand of Biomass
Oxygen Demand of Biomass is the amount of oxygen required by the microorganisms to decompose organic matter present in biomass.
Symbol: DO2
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Volume of Wasted Sludge per day
Volume of Wasted Sludge per day is the amount of sludge that is removed or wasted from a wastewater treatment process on a daily basis.
Symbol: Qw
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
MLSS in Returned or Wasted Sludge
MLSS in Returned or Wasted Sludge is the mixed liquor suspended solids in returned sludge in terms of mg per liter.
Symbol: XR
Measurement: DensityUnit: mg/L
Note: Value should be greater than 0.
Sewage Discharge
Sewage Discharge is the flow rate of sewage when it is being discharged in the river.
Symbol: Qs
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.

Other Formulas to find Influent BOD

​Go Influent BOD given Oxygen Required in Aeration Tank
Qi=Qo+(f(O2+(1.42QwXR))Qs)
​Go Influent BOD given Oxygen Demand of Biomass
Qi=Qb+(f(O2+(DO2QwXR))Qs)

How to Evaluate Influent BOD given Oxygen Demand and Ultimate BOD Both?

Influent BOD given Oxygen Demand and Ultimate BOD Both evaluator uses Influent BOD = Effluent BOD given Oxygen Demand and Ultimate BOD+(((5 Days BOD/Ultimate BOD)*(Theoretical Oxygen Requirement+(Oxygen Demand of Biomass*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Discharge) to evaluate the Influent BOD, The Influent BOD given Oxygen Demand and Ultimate BOD Both formula is defined as the calculation of influent BOD when we have prior information of oxygen demand and ultimate BOD. Influent BOD is denoted by Qi symbol.

How to evaluate Influent BOD given Oxygen Demand and Ultimate BOD Both using this online evaluator? To use this online evaluator for Influent BOD given Oxygen Demand and Ultimate BOD Both, enter Effluent BOD given Oxygen Demand and Ultimate BOD (Qu), 5 Days BOD (BOD5), Ultimate BOD (BODu), Theoretical Oxygen Requirement (O2), Oxygen Demand of Biomass (DO2), Volume of Wasted Sludge per day (Qw), MLSS in Returned or Wasted Sludge (XR) & Sewage Discharge (Qs) and hit the calculate button.

FAQs on Influent BOD given Oxygen Demand and Ultimate BOD Both

What is the formula to find Influent BOD given Oxygen Demand and Ultimate BOD Both?
The formula of Influent BOD given Oxygen Demand and Ultimate BOD Both is expressed as Influent BOD = Effluent BOD given Oxygen Demand and Ultimate BOD+(((5 Days BOD/Ultimate BOD)*(Theoretical Oxygen Requirement+(Oxygen Demand of Biomass*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Discharge). Here is an example- 14113.33 = 0.011373+(((0.00136/0.002)*(2.89351851851852E-11+(2.02*9.5*0.0014)))/10).
How to calculate Influent BOD given Oxygen Demand and Ultimate BOD Both?
With Effluent BOD given Oxygen Demand and Ultimate BOD (Qu), 5 Days BOD (BOD5), Ultimate BOD (BODu), Theoretical Oxygen Requirement (O2), Oxygen Demand of Biomass (DO2), Volume of Wasted Sludge per day (Qw), MLSS in Returned or Wasted Sludge (XR) & Sewage Discharge (Qs) we can find Influent BOD given Oxygen Demand and Ultimate BOD Both using the formula - Influent BOD = Effluent BOD given Oxygen Demand and Ultimate BOD+(((5 Days BOD/Ultimate BOD)*(Theoretical Oxygen Requirement+(Oxygen Demand of Biomass*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Discharge).
What are the other ways to Calculate Influent BOD?
Here are the different ways to Calculate Influent BOD-
  • Influent BOD=Effluent BOD given Oxygen Required+((Ratio of BOD to Ultimate BOD*(Theoretical Oxygen Requirement+(1.42*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Discharge)OpenImg
  • Influent BOD=Effluent BOD given Oxygen Demand of Biomass+((Ratio of BOD to Ultimate BOD*(Theoretical Oxygen Requirement+(Oxygen Demand of Biomass*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Discharge)OpenImg
  • Influent BOD=Effluent BOD given Ultimate BOD+(((5 Days BOD/Ultimate BOD)*(Theoretical Oxygen Requirement+(1.42*Volume of Wasted Sludge per day*MLSS in Returned or Wasted Sludge)))/Sewage Discharge)OpenImg
Can the Influent BOD given Oxygen Demand and Ultimate BOD Both be negative?
No, the Influent BOD given Oxygen Demand and Ultimate BOD Both, measured in Density cannot be negative.
Which unit is used to measure Influent BOD given Oxygen Demand and Ultimate BOD Both?
Influent BOD given Oxygen Demand and Ultimate BOD Both is usually measured using the Milligram per Liter[mg/L] for Density. Kilogram per Cubic Meter[mg/L], Kilogram per Cubic Centimeter[mg/L], Gram per Cubic Meter[mg/L] are the few other units in which Influent BOD given Oxygen Demand and Ultimate BOD Both can be measured.
Copied!