Inflow Rate between Inter-Isochrone Area Formula

Fx Copy
LaTeX Copy
Inflow Rate for a given catchment area is the average volume of incoming water in unit time at any interval of time of the day. Check FAQs
I=2.78ArΔt
I - Inflow Rate?Ar - Inter-Isochrone Area?Δt - Time Interval?

Inflow Rate between Inter-Isochrone Area Example

With values
With units
Only example

Here is how the Inflow Rate between Inter-Isochrone Area equation looks like with Values.

Here is how the Inflow Rate between Inter-Isochrone Area equation looks like with Units.

Here is how the Inflow Rate between Inter-Isochrone Area equation looks like.

27.8Edit=2.7850Edit5Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Inflow Rate between Inter-Isochrone Area

Inflow Rate between Inter-Isochrone Area Solution

Follow our step by step solution on how to calculate Inflow Rate between Inter-Isochrone Area?

FIRST Step Consider the formula
I=2.78ArΔt
Next Step Substitute values of Variables
I=2.78505s
Next Step Prepare to Evaluate
I=2.78505
LAST Step Evaluate
I=27.8m³/s

Inflow Rate between Inter-Isochrone Area Formula Elements

Variables
Inflow Rate
Inflow Rate for a given catchment area is the average volume of incoming water in unit time at any interval of time of the day.
Symbol: I
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Inter-Isochrone Area
Inter-Isochrone Area divides area of watershed into subareas with distinct runoff translation times.
Symbol: Ar
Measurement: AreaUnit:
Note: Value can be positive or negative.
Time Interval
Time Interval is the amount of time required for the change from the initial to the final state.
Symbol: Δt
Measurement: TimeUnit: s
Note: Value should be greater than 0.

Other formulas in Clark's Method for IUH category

​Go Inter-Isochrone Area given Inflow
Ar=IΔt2.78
​Go Time Interval at Inter-Isochrone Area given Inflow
Δt=2.78ArI
​Go Outflow at End of Time Interval for Routing of Time-Area Histogram
Q2=2C1I1+C2Q1
​Go Outflow at Beginning of Time Interval for Routing of Time-Area Histogram
Q1=Q2-(2C1I1)C2

How to Evaluate Inflow Rate between Inter-Isochrone Area?

Inflow Rate between Inter-Isochrone Area evaluator uses Inflow Rate = 2.78*Inter-Isochrone Area/Time Interval to evaluate the Inflow Rate, The Inflow Rate between Inter-Isochrone Area formula is defined as the source of the water within the body of water. It can also refer to the average volume of incoming water in unit time. Inflow Rate is denoted by I symbol.

How to evaluate Inflow Rate between Inter-Isochrone Area using this online evaluator? To use this online evaluator for Inflow Rate between Inter-Isochrone Area, enter Inter-Isochrone Area (Ar) & Time Interval (Δt) and hit the calculate button.

FAQs on Inflow Rate between Inter-Isochrone Area

What is the formula to find Inflow Rate between Inter-Isochrone Area?
The formula of Inflow Rate between Inter-Isochrone Area is expressed as Inflow Rate = 2.78*Inter-Isochrone Area/Time Interval. Here is an example- 27.8 = 2.78*50/5.
How to calculate Inflow Rate between Inter-Isochrone Area?
With Inter-Isochrone Area (Ar) & Time Interval (Δt) we can find Inflow Rate between Inter-Isochrone Area using the formula - Inflow Rate = 2.78*Inter-Isochrone Area/Time Interval.
Can the Inflow Rate between Inter-Isochrone Area be negative?
No, the Inflow Rate between Inter-Isochrone Area, measured in Volumetric Flow Rate cannot be negative.
Which unit is used to measure Inflow Rate between Inter-Isochrone Area?
Inflow Rate between Inter-Isochrone Area is usually measured using the Cubic Meter per Second[m³/s] for Volumetric Flow Rate. Cubic Meter per Day[m³/s], Cubic Meter per Hour[m³/s], Cubic Meter per Minute[m³/s] are the few other units in which Inflow Rate between Inter-Isochrone Area can be measured.