Fx Copy
LaTeX Copy
Infiltration Capacity at Any Time t from the start of the rainfall is the rate at which water percolates in the soil. Check FAQs
fp=m+nFp
fp - Infiltration Capacity at Any Time t?m - Parameter 'm' of Infiltration Model by Green-Ampt?n - Parameter 'n' of Infiltration Model by Green-Ampt?Fp - Cumulative Infiltration Capacity?

Infiltration Capacity given Green-Ampt Parameters of Infiltration Model Example

With values
With units
Only example

Here is how the Infiltration Capacity given Green-Ampt Parameters of Infiltration Model equation looks like with Values.

Here is how the Infiltration Capacity given Green-Ampt Parameters of Infiltration Model equation looks like with Units.

Here is how the Infiltration Capacity given Green-Ampt Parameters of Infiltration Model equation looks like.

16Edit=14Edit+40Edit20Edit
You are here -
HomeIcon Home » Category Engineering » Category Civil » Category Engineering Hydrology » fx Infiltration Capacity given Green-Ampt Parameters of Infiltration Model

Infiltration Capacity given Green-Ampt Parameters of Infiltration Model Solution

Follow our step by step solution on how to calculate Infiltration Capacity given Green-Ampt Parameters of Infiltration Model?

FIRST Step Consider the formula
fp=m+nFp
Next Step Substitute values of Variables
fp=14+4020cm/h
Next Step Prepare to Evaluate
fp=14+4020
Next Step Evaluate
fp=4.44444444444444E-05m/s
LAST Step Convert to Output's Unit
fp=16cm/h

Infiltration Capacity given Green-Ampt Parameters of Infiltration Model Formula Elements

Variables
Infiltration Capacity at Any Time t
Infiltration Capacity at Any Time t from the start of the rainfall is the rate at which water percolates in the soil.
Symbol: fp
Measurement: SpeedUnit: cm/h
Note: Value should be greater than 0.
Parameter 'm' of Infiltration Model by Green-Ampt
Parameter 'm' of Infiltration Model by Green-Ampt method that allows the application of the Green-Ampt infiltration model to any watershed for which soil survey data exists.
Symbol: m
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Parameter 'n' of Infiltration Model by Green-Ampt
Parameter 'n' of Infiltration Model by Green-Ampt method taht allows the application of the Green-Ampt infiltration model to any watershed for which soil survey data exists.
Symbol: n
Measurement: NAUnit: Unitless
Note: Value should be greater than 0.
Cumulative Infiltration Capacity
Cumulative Infiltration Capacity is calculated by subtracting the cumulative runoff from the cumulative rainfall.
Symbol: Fp
Measurement: SpeedUnit: cm/h
Note: Value should be greater than 0.

Other Formulas to find Infiltration Capacity at Any Time t

​Go Green Ampt Equation
fp=K(1+ηScFp)

Other formulas in Green Ampt Equation (1911) category

​Go Porosity of Soil given Infiltration Capacity from Green-Ampt Equation
η=(fpK-1)FpSc
​Go Capillary Suction given Infiltration Capacity
Sc=(fpK-1)Fpη
​Go Darcy's Hydraulic Conductivity given Infiltration Capacity from Green-Ampt Equation
K=fp1+ηScFp
​Go Cumulative Infiltration Capacity given Green-Ampt Parameters of Infiltration Model
Fp=nfp-m

How to Evaluate Infiltration Capacity given Green-Ampt Parameters of Infiltration Model?

Infiltration Capacity given Green-Ampt Parameters of Infiltration Model evaluator uses Infiltration Capacity at Any Time t = Parameter 'm' of Infiltration Model by Green-Ampt+Parameter 'n' of Infiltration Model by Green-Ampt/Cumulative Infiltration Capacity to evaluate the Infiltration Capacity at Any Time t, The Infiltration Capacity given Green-Ampt Parameters of Infiltration Model formula is defined as the infiltration capacity decreases as soil moisture content of soil surface layers increases. Infiltration Capacity at Any Time t is denoted by fp symbol.

How to evaluate Infiltration Capacity given Green-Ampt Parameters of Infiltration Model using this online evaluator? To use this online evaluator for Infiltration Capacity given Green-Ampt Parameters of Infiltration Model, enter Parameter 'm' of Infiltration Model by Green-Ampt (m), Parameter 'n' of Infiltration Model by Green-Ampt (n) & Cumulative Infiltration Capacity (Fp) and hit the calculate button.

FAQs on Infiltration Capacity given Green-Ampt Parameters of Infiltration Model

What is the formula to find Infiltration Capacity given Green-Ampt Parameters of Infiltration Model?
The formula of Infiltration Capacity given Green-Ampt Parameters of Infiltration Model is expressed as Infiltration Capacity at Any Time t = Parameter 'm' of Infiltration Model by Green-Ampt+Parameter 'n' of Infiltration Model by Green-Ampt/Cumulative Infiltration Capacity. Here is an example- 5.8E+6 = 14+40/5.55555555555556E-05.
How to calculate Infiltration Capacity given Green-Ampt Parameters of Infiltration Model?
With Parameter 'm' of Infiltration Model by Green-Ampt (m), Parameter 'n' of Infiltration Model by Green-Ampt (n) & Cumulative Infiltration Capacity (Fp) we can find Infiltration Capacity given Green-Ampt Parameters of Infiltration Model using the formula - Infiltration Capacity at Any Time t = Parameter 'm' of Infiltration Model by Green-Ampt+Parameter 'n' of Infiltration Model by Green-Ampt/Cumulative Infiltration Capacity.
What are the other ways to Calculate Infiltration Capacity at Any Time t?
Here are the different ways to Calculate Infiltration Capacity at Any Time t-
  • Infiltration Capacity at Any Time t=Darcy's Hydraulic Conductivity*(1+(Porosity*Capillary Suction at Wetting Front)/Cumulative Infiltration Capacity)OpenImg
Can the Infiltration Capacity given Green-Ampt Parameters of Infiltration Model be negative?
No, the Infiltration Capacity given Green-Ampt Parameters of Infiltration Model, measured in Speed cannot be negative.
Which unit is used to measure Infiltration Capacity given Green-Ampt Parameters of Infiltration Model?
Infiltration Capacity given Green-Ampt Parameters of Infiltration Model is usually measured using the Centimeter per Hour[cm/h] for Speed. Meter per Second[cm/h], Meter per Minute[cm/h], Meter per Hour[cm/h] are the few other units in which Infiltration Capacity given Green-Ampt Parameters of Infiltration Model can be measured.
Copied!