Impeller power Formula

Fx Copy
LaTeX Copy
The Impeller Power of Centrifugal Pump is the power developed at the impeller in the centrifugal pump. Check FAQs
IP=wQVw2u21000[g]
IP - Impeller Power of Centrifugal Pump?w - Specific Weight of Fluid in Pump?Q - Actual Discharge at Centrifugal Pump Outlet?Vw2 - Velocity of Whirl at Outlet?u2 - Tangential Velocity of Impeller at Outlet?[g] - Gravitational acceleration on Earth?

Impeller power Example

With values
With units
Only example

Here is how the Impeller power equation looks like with Values.

Here is how the Impeller power equation looks like with Units.

Here is how the Impeller power equation looks like.

17.0298Edit=9.81Edit0.056Edit16Edit19Edit10009.8066
You are here -
HomeIcon Home » Category Physics » Category Mechanical » Category Fluid Mechanics » fx Impeller power

Impeller power Solution

Follow our step by step solution on how to calculate Impeller power?

FIRST Step Consider the formula
IP=wQVw2u21000[g]
Next Step Substitute values of Variables
IP=9.81kN/m³0.056m³/s16m/s19m/s1000[g]
Next Step Substitute values of Constants
IP=9.81kN/m³0.056m³/s16m/s19m/s10009.8066m/s²
Next Step Convert Units
IP=9810N/m³0.056m³/s16m/s19m/s10009.8066m/s²
Next Step Prepare to Evaluate
IP=98100.056161910009.8066
Next Step Evaluate
IP=17029.8154823513W
Next Step Convert to Output's Unit
IP=17.0298154823513kW
LAST Step Rounding Answer
IP=17.0298kW

Impeller power Formula Elements

Variables
Constants
Impeller Power of Centrifugal Pump
The Impeller Power of Centrifugal Pump is the power developed at the impeller in the centrifugal pump.
Symbol: IP
Measurement: PowerUnit: kW
Note: Value should be greater than 0.
Specific Weight of Fluid in Pump
Specific weight of fluid in pump is the weight of fluid per unit volume.
Symbol: w
Measurement: Specific WeightUnit: kN/m³
Note: Value should be greater than 0.
Actual Discharge at Centrifugal Pump Outlet
Actual discharge at centrifugal pump outlet is the actual amount of the liquid outflow from the outlet of the centrifugal pump.
Symbol: Q
Measurement: Volumetric Flow RateUnit: m³/s
Note: Value should be greater than 0.
Velocity of Whirl at Outlet
The Velocity of Whirl at Outlet is the tangential component of absolute velocity at the blade outlet.
Symbol: Vw2
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Tangential Velocity of Impeller at Outlet
The Tangential Velocity of Impeller at Outlet is the velocity of the impeller at the fluid outlet.
Symbol: u2
Measurement: SpeedUnit: m/s
Note: Value should be greater than 0.
Gravitational acceleration on Earth
Gravitational acceleration on Earth means that the velocity of an object in free fall will increase by 9.8 m/s2 every second.
Symbol: [g]
Value: 9.80665 m/s²

Other formulas in Impeller Parameters category

​Go Impeller radius at inlet given inlet tangential velocity
R1=u1ω
​Go Impeller radius at outlet given outlet tangential velocity
R2=u2ω
​Go Outlet Diameter of Impeller using Speed Ratio, Manometric Head and Impeller Speed
D2=84.6KuHmω
​Go Least diameter of impeller when outlet diameter is twice of inlet diameter
D2=97.68Hmω

How to Evaluate Impeller power?

Impeller power evaluator uses Impeller Power of Centrifugal Pump = (Specific Weight of Fluid in Pump*Actual Discharge at Centrifugal Pump Outlet*Velocity of Whirl at Outlet*Tangential Velocity of Impeller at Outlet)/(1000*[g]) to evaluate the Impeller Power of Centrifugal Pump, The Impeller power formula is defined as the ratio of product of specific weight, discharge, whirl velocity and tangential velocity at outlet to the product of 1000 times acceleration due to gravity. Impeller Power of Centrifugal Pump is denoted by IP symbol.

How to evaluate Impeller power using this online evaluator? To use this online evaluator for Impeller power, enter Specific Weight of Fluid in Pump (w), Actual Discharge at Centrifugal Pump Outlet (Q), Velocity of Whirl at Outlet (Vw2) & Tangential Velocity of Impeller at Outlet (u2) and hit the calculate button.

FAQs on Impeller power

What is the formula to find Impeller power?
The formula of Impeller power is expressed as Impeller Power of Centrifugal Pump = (Specific Weight of Fluid in Pump*Actual Discharge at Centrifugal Pump Outlet*Velocity of Whirl at Outlet*Tangential Velocity of Impeller at Outlet)/(1000*[g]). Here is an example- 0.01703 = (9810*0.056*16*19)/(1000*[g]).
How to calculate Impeller power?
With Specific Weight of Fluid in Pump (w), Actual Discharge at Centrifugal Pump Outlet (Q), Velocity of Whirl at Outlet (Vw2) & Tangential Velocity of Impeller at Outlet (u2) we can find Impeller power using the formula - Impeller Power of Centrifugal Pump = (Specific Weight of Fluid in Pump*Actual Discharge at Centrifugal Pump Outlet*Velocity of Whirl at Outlet*Tangential Velocity of Impeller at Outlet)/(1000*[g]). This formula also uses Gravitational acceleration on Earth constant(s).
Can the Impeller power be negative?
No, the Impeller power, measured in Power cannot be negative.
Which unit is used to measure Impeller power?
Impeller power is usually measured using the Kilowatt[kW] for Power. Watt[kW], Milliwatt[kW], Microwatt[kW] are the few other units in which Impeller power can be measured.
Copied!