The Impedance of Secondary Winding is the impedance you anticipate the device connected to the transformer secondary side to have. Check FAQs
Z2=E2-V2I2
Z2 - Impedance of Secondary?E2 - EMF Induced in Secondary?V2 - Secondary Voltage?I2 - Secondary Current?

Impedance of Secondary Winding given Secondary Parameters Example

With values
With units
Only example

Here is how the Impedance of Secondary Winding given Secondary Parameters equation looks like with Values.

Here is how the Impedance of Secondary Winding given Secondary Parameters equation looks like with Units.

Here is how the Impedance of Secondary Winding given Secondary Parameters equation looks like.

-25.92Edit=15.84Edit-288Edit10.5Edit
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Machine » fx Impedance of Secondary Winding given Secondary Parameters

Impedance of Secondary Winding given Secondary Parameters Solution

Follow our step by step solution on how to calculate Impedance of Secondary Winding given Secondary Parameters?

FIRST Step Consider the formula
Z2=E2-V2I2
Next Step Substitute values of Variables
Z2=15.84V-288V10.5A
Next Step Prepare to Evaluate
Z2=15.84-28810.5
LAST Step Evaluate
Z2=-25.92Ω

Impedance of Secondary Winding given Secondary Parameters Formula Elements

Variables
Impedance of Secondary
The Impedance of Secondary Winding is the impedance you anticipate the device connected to the transformer secondary side to have.
Symbol: Z2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
EMF Induced in Secondary
EMF Induced in Secondary Winding is the production of voltage in a coil because of the change in magnetic flux through a coil.
Symbol: E2
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Secondary Voltage
Secondary Voltage is defined as the voltage on the secondary side of a transformer or the side at which load is connected.
Symbol: V2
Measurement: Electric PotentialUnit: V
Note: Value can be positive or negative.
Secondary Current
Secondary Current is the current which is flows in the secondary winding of transformer.
Symbol: I2
Measurement: Electric CurrentUnit: A
Note: Value can be positive or negative.

Other Formulas to find Impedance of Secondary

​Go Impedance of Secondary Winding
Z2=R22+XL22

Other formulas in Impedance category

​Go Impedance of Primary Winding given Primary Parameters
Z1=V1-E1I1
​Go Impedance of Primary Winding
Z1=R12+XL12
​Go Equivalent Impedance of Transformer from Primary Side
Z01=R012+X012
​Go Equivalent Impedance of Transformer from Secondary Side
Z02=R022+X022

How to Evaluate Impedance of Secondary Winding given Secondary Parameters?

Impedance of Secondary Winding given Secondary Parameters evaluator uses Impedance of Secondary = (EMF Induced in Secondary-Secondary Voltage)/Secondary Current to evaluate the Impedance of Secondary, The Impedance of Secondary Winding given Secondary Parameters formula is defined as the impedance in the secondary winding of the transformer. Impedance of Secondary is denoted by Z2 symbol.

How to evaluate Impedance of Secondary Winding given Secondary Parameters using this online evaluator? To use this online evaluator for Impedance of Secondary Winding given Secondary Parameters, enter EMF Induced in Secondary (E2), Secondary Voltage (V2) & Secondary Current (I2) and hit the calculate button.

FAQs on Impedance of Secondary Winding given Secondary Parameters

What is the formula to find Impedance of Secondary Winding given Secondary Parameters?
The formula of Impedance of Secondary Winding given Secondary Parameters is expressed as Impedance of Secondary = (EMF Induced in Secondary-Secondary Voltage)/Secondary Current. Here is an example- -25.92 = (15.84-288)/10.5.
How to calculate Impedance of Secondary Winding given Secondary Parameters?
With EMF Induced in Secondary (E2), Secondary Voltage (V2) & Secondary Current (I2) we can find Impedance of Secondary Winding given Secondary Parameters using the formula - Impedance of Secondary = (EMF Induced in Secondary-Secondary Voltage)/Secondary Current.
What are the other ways to Calculate Impedance of Secondary?
Here are the different ways to Calculate Impedance of Secondary-
  • Impedance of Secondary=sqrt(Resistance of Secondary^2+Secondary Leakage Reactance^2)OpenImg
Can the Impedance of Secondary Winding given Secondary Parameters be negative?
Yes, the Impedance of Secondary Winding given Secondary Parameters, measured in Electric Resistance can be negative.
Which unit is used to measure Impedance of Secondary Winding given Secondary Parameters?
Impedance of Secondary Winding given Secondary Parameters is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Impedance of Secondary Winding given Secondary Parameters can be measured.
Copied!