Fx Copy
LaTeX Copy
Impedance of Tertiary Winding in electrical devices, refers to the amount of opposition faced by the direct or alternating current when it passes through a conductor component, circuit, or system. Check FAQs
Z3=(2Z1(ρv+1))-(1Z1)-(1Z2)
Z3 - Impedance of Tertiary Winding?Z1 - Impedance of Primary Winding?ρv - Reflection Coefficient of Voltage?Z2 - Impedance of Secondary Winding?

Impedance-3 using Reflected Coefficient of Voltage (Line PL) Example

With values
With units
Only example

Here is how the Impedance-3 using Reflected Coefficient of Voltage (Line PL) equation looks like with Values.

Here is how the Impedance-3 using Reflected Coefficient of Voltage (Line PL) equation looks like with Units.

Here is how the Impedance-3 using Reflected Coefficient of Voltage (Line PL) equation looks like.

0.5486Edit=(218Edit(5Edit+1))-(118Edit)-(116Edit)
You are here -
HomeIcon Home » Category Engineering » Category Electrical » Category Power System » fx Impedance-3 using Reflected Coefficient of Voltage (Line PL)

Impedance-3 using Reflected Coefficient of Voltage (Line PL) Solution

Follow our step by step solution on how to calculate Impedance-3 using Reflected Coefficient of Voltage (Line PL)?

FIRST Step Consider the formula
Z3=(2Z1(ρv+1))-(1Z1)-(1Z2)
Next Step Substitute values of Variables
Z3=(218Ω(5+1))-(118Ω)-(116Ω)
Next Step Prepare to Evaluate
Z3=(218(5+1))-(118)-(116)
Next Step Evaluate
Z3=0.548611111111111Ω
LAST Step Rounding Answer
Z3=0.5486Ω

Impedance-3 using Reflected Coefficient of Voltage (Line PL) Formula Elements

Variables
Impedance of Tertiary Winding
Impedance of Tertiary Winding in electrical devices, refers to the amount of opposition faced by the direct or alternating current when it passes through a conductor component, circuit, or system.
Symbol: Z3
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.
Impedance of Primary Winding
The Impedance of Primary Winding is the total of primary Resistance and Reactance.
Symbol: Z1
Measurement: Electric ResistanceUnit: Ω
Note: Value should be greater than 0.
Reflection Coefficient of Voltage
Reflection Coefficient Of Voltage is defined as the ratio of the reflected voltage to the incident voltage of the Transmission line during any transient condition.
Symbol: ρv
Measurement: NAUnit: Unitless
Note: Value can be positive or negative.
Impedance of Secondary Winding
The Impedance of Secondary Winding is the impedance that is in Secondary winding.
Symbol: Z2
Measurement: Electric ResistanceUnit: Ω
Note: Value can be positive or negative.

Other Formulas to find Impedance of Tertiary Winding

​Go Impedance-3 using Transmitted Voltage (Line PL)
Z3=VtIt
​Go Impedance-3 using Transmitted Coefficient of Voltage (Line PL)
Z3=(2Z1τv)-(1Z1)-(1Z2)
​Go Impedance-3 using Transmitted Coefficient of Current-3 (Line PL)
Z3=VtZ1Viτi
​Go Impedance-3 for Transmitted Coefficient of Current-3 (Line PL)
Z3=τvZ1τi

Other formulas in Impedance 1,2 and 3 category

​Go Impedance-2 using Transmitted Current-2 (Line PL)
Z2=VtIt
​Go Impedance-2 using Transmitted Voltage (Line PL)
Z2=VtIt
​Go Impedance-1 using Transmitted Voltage (Line PL)
Z1=(Vi-Er)Z2+Z3Vt
​Go Impedance-2 using Transmitted Coefficient of Voltage (Line PL)
Z2=(2Z1τv)-(1Z1)-(1Z3)

How to Evaluate Impedance-3 using Reflected Coefficient of Voltage (Line PL)?

Impedance-3 using Reflected Coefficient of Voltage (Line PL) evaluator uses Impedance of Tertiary Winding = (2/Impedance of Primary Winding*(Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding) to evaluate the Impedance of Tertiary Winding, The Impedance-3 using Reflected Coefficient of Voltage (line PL) formula is defined as a measure of the overall opposition of a circuit to current, in other words: how much the circuit impedes the flow of charge. It is like resistance, but it also takes into account the effects of capacitance and inductance. Impedance-3 is measured in ohms. Impedance of Tertiary Winding is denoted by Z3 symbol.

How to evaluate Impedance-3 using Reflected Coefficient of Voltage (Line PL) using this online evaluator? To use this online evaluator for Impedance-3 using Reflected Coefficient of Voltage (Line PL), enter Impedance of Primary Winding (Z1), Reflection Coefficient of Voltage v) & Impedance of Secondary Winding (Z2) and hit the calculate button.

FAQs on Impedance-3 using Reflected Coefficient of Voltage (Line PL)

What is the formula to find Impedance-3 using Reflected Coefficient of Voltage (Line PL)?
The formula of Impedance-3 using Reflected Coefficient of Voltage (Line PL) is expressed as Impedance of Tertiary Winding = (2/Impedance of Primary Winding*(Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding). Here is an example- 0.548611 = (2/18*(5+1))-(1/18)-(1/16).
How to calculate Impedance-3 using Reflected Coefficient of Voltage (Line PL)?
With Impedance of Primary Winding (Z1), Reflection Coefficient of Voltage v) & Impedance of Secondary Winding (Z2) we can find Impedance-3 using Reflected Coefficient of Voltage (Line PL) using the formula - Impedance of Tertiary Winding = (2/Impedance of Primary Winding*(Reflection Coefficient of Voltage+1))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding).
What are the other ways to Calculate Impedance of Tertiary Winding?
Here are the different ways to Calculate Impedance of Tertiary Winding-
  • Impedance of Tertiary Winding=Transmitted Voltage/Transmitted CurrentOpenImg
  • Impedance of Tertiary Winding=(2/(Impedance of Primary Winding*Transmission Coefficient of Voltage))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding)OpenImg
  • Impedance of Tertiary Winding=Transmitted Voltage*Impedance of Primary Winding/(Incident Voltage*Transmission Coefficient of Current)OpenImg
Can the Impedance-3 using Reflected Coefficient of Voltage (Line PL) be negative?
Yes, the Impedance-3 using Reflected Coefficient of Voltage (Line PL), measured in Electric Resistance can be negative.
Which unit is used to measure Impedance-3 using Reflected Coefficient of Voltage (Line PL)?
Impedance-3 using Reflected Coefficient of Voltage (Line PL) is usually measured using the Ohm[Ω] for Electric Resistance. Megohm[Ω], Microhm[Ω], Volt per Ampere[Ω] are the few other units in which Impedance-3 using Reflected Coefficient of Voltage (Line PL) can be measured.
Copied!